Experimental and Analytical Investigation of D-Type Self-Centering Steel Eccentrically Braced Frames with Replaceable Hysteretic Damping Devices

被引:27
作者
Tong, Lewei [1 ,2 ]
Zhang, Yunfeng [3 ]
Zhou, Xin [2 ]
Keivan, Arshia [3 ]
Li, Ruipeng [3 ]
机构
[1] Tongji Univ, State Key Lab Disaster Reduct Civil Engn, Shanghai 200092, Peoples R China
[2] Tongji Univ, Dept Struct Engn, Shanghai 200092, Peoples R China
[3] Univ Maryland, Dept Civil & Environm Engn, College Pk, MD 20742 USA
关键词
Cyclic loading; Eccentrically braced frames; Experimental testing; Fuse device; Post-tensioning; Replaceable damping device; Seismic performance; Self-centering; SHAPE-MEMORY ALLOY; SEISMIC PERFORMANCE; FRICTION DEVICES; LINK BEAMS; CONNECTIONS; BEHAVIOR; COLUMN; SYSTEMS; DESIGN; TENDONS;
D O I
10.1061/(ASCE)ST.1943-541X.0002235
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the results of an experimental investigation of D-type self-centering eccentrically braced frames (SCEBF) subjected to cyclic loading. Analytical formulation of the SCEBF module frame's load-displacement relationship is first presented. A total of five one-bay one-story SCEBF module frame specimens were experimentally tested under cyclic loading to investigate their seismic behavior. Finite-element simulation study of Specimen SCEBF2 was also conducted to assist with specimen design. The replaceable hysteretic damping (RHD) devices made of low-yield steel were installed at the corners of a rocking link beam to use the amplified motion due to the rocking link beam's rotation and gap opening for energy dissipation. The experimental test results revealed that all the SCEBF specimens were capable of recentering and that the damage was confined to the RHD devices. It was also found that after severe cyclic loading, the SCEBF module frames with replaced RHD devices exhibited almost identical stiffness, strength, recentering ability, and energy dissipation capacity to those of the original structure.
引用
收藏
页数:13
相关论文
共 44 条
[1]  
AISC, 2010, 303 AISC
[2]  
[Anonymous], 2002, THESIS LEHIGH U
[3]  
[Anonymous], 2015, THESIS
[4]  
[Anonymous], 2010, ANSI/AISC 341: Seismic provisions for structural steel buildings
[5]  
Cheng C, 2012, P 15 WORLD C EARTHQ
[6]   Posttensioned energy dissipating connections for moment-resisting steel frames [J].
Christopoulos, C ;
Filiatrault, A ;
Uang, CM ;
Folz, B .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2002, 128 (09) :1111-1120
[7]   Seismic response of self-centring hysteretic SDOF systems [J].
Christopoulos, C ;
Filiatrault, A ;
Folz, B .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2002, 31 (05) :1131-1150
[8]   Experimental Investigation of Self-Centering Steel Plate Shear Walls [J].
Clayton, Patricia M. ;
Winkley, Tyler B. ;
Berman, Jeffrey W. ;
Lowes, Laura N. .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2012, 138 (07) :952-960
[9]  
Dolce M, 2000, EARTHQUAKE ENG STRUC, V29, P945, DOI 10.1002/1096-9845(200007)29:7<945::AID-EQE958>3.0.CO
[10]  
2-#