Condition Assessment of Prestressed Concrete Beams Using Cyclic and Monotonic Load Tests

被引:0
作者
ElBatanouny, Mohamed K. [1 ]
Nanni, Antonio [2 ]
Ziehl, Paul H. [1 ]
Matta, Fabio [1 ]
机构
[1] Univ S Carolina, Dept Civil & Environm Engn, Columbia, SC 29208 USA
[2] Univ Miami, Dept Civil Architectural & Environm Engn, Coral Gables, FL 33124 USA
关键词
corrosion; cyclic load test (CLT); monotonic (24-hour) load test; prestressed concrete (PC); IN-SITU EVALUATION; SLAB SYSTEMS;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Eight prestressed T-shaped beams were tested using the cyclic load test (CLT) method as proposed by ACI 437-12 followed by the ACI 318-11 monotonic (24-hour) load test method. The objective of the study is to assess the ability of these methods to evaluate damage in prestressed concrete (PC) beams. The test matrix included both pristine beams (subjected to no prior loading) as well as beams that were cracked and artificially predamaged using accelerated corrosion techniques, impressed current, and wet/dry cycles, prior to load testing. Deflections, crack widths, and slipping of the prestressing strands were recorded during the load tests. The load at which the monotonic test was conducted was chosen to be greater than the service load of Class U PC members, which does not allow cracking. This ensured that at the time of the monotonic load test the specimens were significantly damaged. However, the acceptance criteria associated with this test methodology were still met. Only one index in the CLT acceptance criteria (deviation from linearity) identified the condition of the specimens. The deviation from linearity index is found to correlate to the opening and widening of cracks.
引用
收藏
页码:81 / 89
页数:9
相关论文
共 18 条
[1]  
[Anonymous], 2012, 43712 ACI COMM
[2]  
[Anonymous], 2011, Building Code Requirements for Structural Concrete (ACI 318-11) and Commentary
[3]  
[Anonymous], 2007, 437IR07 ACI COMM
[4]  
ASCE, 2009, REP CARD AM INFR
[5]  
Auyeung Y, 2000, ACI MATER J, V97, P214
[6]   In Situ Load Testing of Parking Garage Reinforced Concrete Slabs: Comparison between 24 h and Cyclic Load Testing [J].
Casadei, Paolo ;
Parretti, Renato ;
Nanni, Antonio ;
Heinze, Tom .
PRACTICE PERIODICAL ON STRUCTURAL DESIGN AND CONSTRUCTION, 2005, 10 (01) :40-48
[7]  
ElBatanouny M., 2012, STRUCTURAL FAULTS RE
[8]  
ElBatanouny M. K., 2012, THESIS U S CAROLINA
[9]   Acoustic emission monitoring for assessment of prestressed concrete beams [J].
ElBatanouny, Mohamed K. ;
Ziehl, Paul H. ;
Larosche, Aaron ;
Mangual, Jese ;
Matta, Fabio ;
Nanni, Antonio .
CONSTRUCTION AND BUILDING MATERIALS, 2014, 58 :46-53
[10]  
Galati N., 2004, Load test evaluation of Augspurger ramp parking garage in Buffalo