Angiographic views used for percutaneous coronary interventions: A three-dimensional analysis of physician-determined vs. computer-generated views

被引:91
作者
Green, NE [1 ]
Chen, SYJ [1 ]
Hansgen, AR [1 ]
Messenger, JC [1 ]
Groves, BM [1 ]
Carroll, JD [1 ]
机构
[1] Univ Colorado, Hlth Sci Ctr, Div Cardiol, Denver, CO 80262 USA
关键词
coronary angiography; three-dimensional imaging; percutaneous transluminal angioplasty; coronary stenosis;
D O I
10.1002/ccd.20331
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The goal of this study was to determine the severity of vessel foreshortening in standard angiographic views used during percutaneous coronary intervention (PCI). Coronary angiography is limited by its two-dimensional (2D) representation of three-dimensional (3D) structures. Vessel foreshortening in angiographic images may cause errors in the assessment of lesions or the selection and placement of stents. To date, no technique has existed to quantify these 2D limitations or the performance of physicians in selecting angiographic views. Stent deployment was performed in 156 vessel segments in 149 patients. Using 3D reconstruction models of each patient's coronary tree, vessel foreshortening was measured in the actual working view used for stent deployment. A computer-generated optimal view was then identified for each vessel segment and compared to the working view. Vessel foreshortening ranged from 0 to 50% in the 156 working views used for stent deployment and varied by coronary artery and by vessel segment within each artery. In general, views of the mid circumflex artery were the most foreshortened and views of the right coronary artery were the least foreshortened. Expert-recommended views frequently resulted in more foreshortening than computer-generated optimal views, which had only 0.5% +/- 1.2% foreshortening with < 2% overlap for the same 156 segments. Optimal views differed from the operator-selected working views by >= 10 degrees in over 90% of vessels and frequently occurred in entirely different imaging quadrants. Vessel foreshortening occurs frequently in standard angiographic projections during stent deployment. If unrecognized by the operator, vessel foreshortening may result in suboptimal clinical results. Modifications to expert-recommended views using 3D reconstruction may improve visualization and the accuracy of stent deployment. These results highlight the limitations of 2D angiography and support the development of real-time 3D techniques to improve visualization during PCI. (c) 2005 Wiley-Liss, Inc.
引用
收藏
页码:451 / 459
页数:9
相关论文
共 41 条
  • [1] Achenbach S, 2001, CIRCULATION, V103, P2535
  • [2] ALDERMAN EL, 1992, CORONARY ARTERY DIS, V3, P1189
  • [3] CORONARY-ARTERY NARROWING IN CORONARY HEART-DISEASE - COMPARISON OF CINEANGIOGRAPHIC AND NECROPSY FINDINGS
    ARNETT, EN
    ISNER, JM
    REDWOOD, DR
    KENT, KM
    BAKER, WP
    ACKERSTEIN, H
    ROBERTS, WC
    [J]. ANNALS OF INTERNAL MEDICINE, 1979, 91 (03) : 350 - 356
  • [4] Baim DS, 2000, GROSSMANS CARDIAC CA, P211
  • [5] CARROLL JD, 2001, CATHSAP 2 CATHETERIZ
  • [6] 3-D reconstruction of coronary arterial tree to optimize angiographic visualization
    Chen, SJ
    Carroll, JD
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (04) : 318 - 336
  • [7] Three-dimensional reconstruction of coronary arterial tree based on biplane angiograms
    Chen, SYJ
    Hoffmann, KR
    Carroll, JD
    [J]. MEDICAL IMAGING 1996: IMAGE PROCESSING, 1996, 2710 : 103 - 114
  • [8] Quantitative analysis of reconstructed 3-D coronary arterial tree and intracoronary devices
    Chen, SYJ
    Carroll, JD
    Messenger, JC
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (07) : 724 - 740
  • [9] Improved determination of biplane imaging geometry from two projection images and its application to three-dimensional reconstruction of coronary arterial trees
    Chen, SYJ
    Metz, CE
    [J]. MEDICAL PHYSICS, 1997, 24 (05) : 633 - 654
  • [10] Chen SYJ, 1998, DEV CARDIOVASC MED, V204, P61