Acetylcholine biosensor based on the electrochemical functionalization of graphene field-effect transistors

被引:108
作者
Fenoy, Gonzalo E. [1 ,2 ]
Marmisolle, Waldemar A. [1 ]
Azzaroni, Omar [1 ,3 ]
Knoll, Wolfgang [4 ,5 ]
机构
[1] Univ Nacl La Plata, Fac Ciencias Exactas, CONICET, Inst Invest Fisicoquim Teor & Aplicadas INIFTA,De, Diagonal 113 & 64, RA-1900 La Plata, Buenos Aires, Argentina
[2] Univ Nacl San Martin, Inst Invest & Ingn Ambiental, 25 Mayo & Francia,1 Piso, RA-1650 Buenos Aires, DF, Argentina
[3] CEST UNLP Partner Lab Bioelect, Diagonal 64 & 113, RA-1900 La Plata, Buenos Aires, Argentina
[4] CEST Competence Ctr Electrochem Surface Technol, Konrad Lorenz Str 24, A-3430 Tulln, Austria
[5] Austrian Inst Technol, Donau City Str 1, A-1220 Vienna, Austria
关键词
Graphene; Field-effect transistor; Acetylcholine; Acetylcholinesterase; gFETs; Electropolymerization; ORGANOPHOSPHATE PESTICIDE DETECTION; IMMOBILIZATION; SURFACE; ELECTRODES; PH;
D O I
10.1016/j.bios.2019.111796
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We present a new strategy of Acetylcholinesterease (AchE) immobilization on graphene field-effect transistors (gFETs) for building up Acetylcholine sensors. This method is based on the electrosynthesis of an amino moiety-bearing polymer layer on the graphene channel. The film of the copolymer poly(3-amino-benzylamine-co-ani-line) (PABA) does not only provide the suitable electrostatic charge and non-denaturing environment for enzyme immobilization, but it also improves the pH sensitivity of the gFETs (from 40.8 to 56.3 mu A/pH unit), probably due to its wider effective pKa distribution. The local pH changes caused by the enzyme-catalyzed hydrolysis produce a shift in the Dirac point of the gFETs to more negative values, which are evidenced as differences in the gFET conductivity and thereby constituted the signal transduction mechanism of the modified transistors. In this way, the constructed biosensors showed a LOD of 2.3 mu M and were able to monitor Ach in the range from 5 to 1000 mu M in a flow configuration. Moreover, they showed a sensitivity of -26.6 +/- 0.7 mu A/Ach decade and also exhibited a very low RSD of 2.6%, revealing good device-to-device reproducibility. The biosensors revealed an excellent selectivity to interferences known to be present in the extracellular milieu, and the response to Ach was recovered by 97.5% after the whole set of interferences injected. Finally, the biosensors showed a fast response time, with an average value of 130 s and a good long-term response.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Simulation of graphene nanoribbon field-effect transistors
    Fiori, Gianluca
    Iannaccone, Giuseppe
    IEEE ELECTRON DEVICE LETTERS, 2007, 28 (08) : 760 - 762
  • [22] Supramolecular Chemistry on Graphene Field-Effect Transistors
    Zhang, Xiaoyan
    Huisman, Everardus H.
    Gurram, Mallikarjuna
    Browne, Wesley R.
    van Wees, Bart J.
    Feringa, Ben L.
    SMALL, 2014, 10 (09) : 1735 - 1740
  • [23] Graphene Field-Effect Transistors With High Extrinsic fT and fmax
    Bonmann, Marlene
    Asad, Muhammad
    Yang, Xinxin
    Generalov, Andrey
    Vorobiev, Andrei
    Banszerus, Luca
    Stampfer, Christoph
    Otto, Martin
    Neumaier, Daniel
    Stake, Jan
    IEEE ELECTRON DEVICE LETTERS, 2019, 40 (01) : 131 - 134
  • [24] The effect of traps on the performance of graphene field-effect transistors
    Zhu, J.
    Jhaveri, R.
    Woo, J. C. S.
    APPLIED PHYSICS LETTERS, 2010, 96 (19)
  • [25] Uniformly Nanopatterned Graphene Field-Effect Transistors with Enhanced Properties
    Duyoung Choi
    Cihan Kuru
    Youngjin Kim
    Gunwoo Kim
    Taekyoung Kim
    Renkun Chen
    Sungho Jin
    Nanoscale Research Letters, 2015, 10
  • [26] Modeling Techniques for Graphene Field-effect Transistors
    Lu, Haiyan
    Wu, Yun
    Huo, Shuai
    Xu, Yuehang
    Kong, Yuechan
    Chen, Tangshen
    2015 IEEE INTERNATIONAL CONFERENCE ON COMMUNICATION PROBLEM-SOLVING (ICCP), 2015, : 373 - 376
  • [27] Toward the Ultimate Limit of Analyte Detection, in Graphene-Based Field-Effect Transistors
    Lee, Alex W.
    Dong, Yongliang
    Natani, Shreyam
    Ban, Deependra Kumar
    Bandaru, Prabhakar R.
    NANO LETTERS, 2024, 24 (04) : 1214 - 1222
  • [28] Ultratrace antibiotic sensing using aptamer/graphene-based field-effect transistors
    Chen, Xiaoyan
    Liu, Ying
    Fang, Xian
    Li, Zhuo
    Pu, Haihui
    Chang, Jingbo
    Chen, Junhong
    Mao, Shun
    BIOSENSORS & BIOELECTRONICS, 2019, 126 : 664 - 671
  • [29] Uniformly Nanopatterned Graphene Field-Effect Transistors with Enhanced Properties
    Choi, Duyoung
    Kuru, Cihan
    Kim, Youngjin
    Kim, Gunwoo
    Kim, Taekyoung
    Chen, Renkun
    Jin, Sungho
    NANOSCALE RESEARCH LETTERS, 2015, 10
  • [30] Simulation of Graphene Field-Effect Transistors and Resonant Tunneling Diodes Based on Carbon Nanomaterials
    Abramov, Igor I.
    Labunov, Vladimir A.
    Kolomejtseva, Natali, V
    Romanova, Irina A.
    Shcherbakova, Irina Y.
    INTERNATIONAL CONFERENCE ON MICRO- AND NANO-ELECTRONICS 2018, 2019, 11022