Effect of alloy type and casting technique on the fracture strength of implant-cemented structures

被引:10
作者
Castillo-de Oyaguee, Raquel [1 ]
Osorio, Raquel [2 ]
Lynch, Christopher [3 ]
Gilmour, Alan [3 ]
Toledano, Manuel [2 ]
机构
[1] Univ Complutense Madrid, Dept Prosthodont, Fac Dent, UCM, E-28040 Madrid, Spain
[2] Univ Granada UGR, Dept Dent, Sch Dent, Granada 18071, Spain
[3] Cardiff Univ, Dept Adult Dent Hlth, Sch Dent, Cardiff CF14 4XY, S Glam, Wales
来源
MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL | 2011年 / 16卷 / 04期
关键词
Metallic framework; titanium; cobalt-chromium; casting technique; fracture strength; CERAMIC RESTORATIONS; SUPPORTED PROSTHESES; DENTURE FRAMEWORKS; COMMERCIALLY PURE; TITANIUM; CASTABILITY; RESISTANCE; DESIGNS;
D O I
10.4317/medoral.16.e619
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To evaluate the influence of alloy type and casting procedure on the fracture strength (FS) of metallic frameworks for implant-supported fixed prostheses. Study design: Thirty three-unit structures for lower posterior bridges were waxed-up and randomly assigned to two groups (n=15) according to alloy type and casting technique: Group 1 (C): cobalt-chromium cast in a centrifugal machine (TS1, Degussa-Huls); Group 2 (T): titanium cast in a pressure-differential device (Cyclarc II, Morita). Each structure was cemented onto two prefabricated abutments under a constant seating pressure. After 6 months of water aging, samples were loaded in a static universal testing machine (EFH/5/FR, Microtest) until fracture. Axial compressive loads were applied at the central fossa of the pontics. FS data were recorded and surface topography of the fractured connectors was SEM-analyzed. A Chi-Square test was performed to assess the dependence of pores on the alloy type and casting procedure. ANOVA and Student-Newman-Keuls (SNK) tests were run for FS comparisons (p<0.05). Results: One third of the C structures showed pores inside the fractured connectors. T frameworks demonstrated higher FS than that of C specimens exhibiting pores (p=0.025). C samples containing no pores recorded the greatest mean FS (p<0.001). Conclusions: Fracture strength of metallic frameworks depended on the alloy type and casting procedure. Cobalt-chromium casts often registered pores inside the connectors, which strongly decreased the fracture resistance. An accurate casting of titanium with a pressure-differential system may result in the most predictable technique under the tested experimental conditions.
引用
收藏
页码:E619 / E625
页数:7
相关论文
共 20 条
  • [1] Which mechanical and physical testing methods are relevant for predicting the clinical performance of ceramic-based dental prostheses?
    Anusavice, K. F.
    Kakar, Kunian
    Ferree, N.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2007, 18 : 218 - 231
  • [2] BESSING C, 1992, SWED DENT J, V16, P109
  • [3] In vitro vertical misfit evaluation of cast frameworks for cement-retained implant-supported partial prostheses
    Castillo Oyaguee, Raquel
    Sanchez Turrion, Andres
    Toledano, Manuel
    Monticelli, Francesca
    Osorio, Raquel
    [J]. JOURNAL OF DENTISTRY, 2009, 37 (01) : 52 - 58
  • [4] Structure, castability and mechanical properties of commercially pure and alloyed titanium cast in graphite mould
    Cheng, W. W.
    Ju, C. P.
    Lin, J. H. Chern
    [J]. JOURNAL OF ORAL REHABILITATION, 2007, 34 (07) : 528 - 540
  • [5] Over-refractory casting technique as an alternative to one-piece multi-unit fixed partial denture frameworks
    Correa, GD
    Henriques, GEP
    Mesquita, MF
    Sobrinho, LC
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2006, 95 (03) : 243 - 248
  • [6] Evaluation of welded titanium joints used with cantilevered implant-supported prostheses
    Hart, Christopher N.
    Wilson, Peter R.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2006, 96 (01) : 25 - 32
  • [7] Hjalmarsson Lars, 2009, Swed Dent J Suppl, P3
  • [8] Effect of cantilever length and framework alloy on the stress distribution of mandibular-cantilevered implant-supported prostheses
    Jacques, Leticia Borges
    Moura, Marcio Silva
    Suedam, Valdey
    Capello Souza, Edson Antonio
    Rubo, Jose Henrique
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (07) : 737 - 741
  • [9] Comparison of castability and surface roughness of commercially pure titanium and cobalt-chromium denture frameworks
    Jang, KS
    Youn, SJ
    Kim, YS
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2001, 86 (01) : 93 - 98
  • [10] Karl Matthias, 2006, J Prosthodont, V15, P20, DOI 10.1111/j.1532-849X.2006.00064.x