Fast, low-pressure gas chromatography triple quadrupole tandem mass spectrometry for analysis of 150 pesticide residues in fruits and vegetables

被引:94
作者
Koesukwiwat, Urairat [1 ,2 ]
Lehotay, Steven J. [1 ]
Leepipatpiboon, Natchanun [2 ]
机构
[1] ARS, USDA, Eastern Reg Res Ctr, Wyndmoor, PA 19038 USA
[2] Chulalongkorn Univ, Fac Sci, Dept Chem, Chromatog & Separat Res Unit, Bangkok 10330, Thailand
关键词
QuEChERS; Sample throughput; Pesticide analysis; Vacuum-outlet gas chromatography; Triple quadrupole mass spectrometry; POLYCYCLIC AROMATIC-HYDROCARBONS; LIQUID-CHROMATOGRAPHY; MULTIRESIDUE METHOD; RAPID ANALYSIS; ESSENTIAL OIL; HIGH-SPEED; TIME; QUECHERS; EXTRACTION; INJECTION;
D O I
10.1016/j.chroma.2011.07.094
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We developed and evaluated a new method of low-pressure gas chromatography-tandem mass spectrometry (LP-GC/MS-MS) using a triple quadrupole instrument for fast analysis of 150 relevant pesticides in four representative fruits and vegetables. This LP-GC (vacuum outlet) approach entails coupling a 10 m, 0.53 mm id., 1 mu m film analytical column between the MS transfer line and a 3m, 0.15 mm id. capillary at the inlet. The MS creates a vacuum in the 10 m analytical column, which reduces the viscosity of the He carrier gas and thereby shifts the optimal flow rate to greater velocity. By taking advantage of the H-2-like properties of He under vacuum, the short analytical column, a rapid oven temperature ramp rate, and the high selectivity and sensitivity of MS/MS, 150 pesticides were separated in <6.5 min. The 2.5 ms dwell time and 1 ms interscan delay of the MS/MS instrument were critical for achieving >8 data points across the 2-3 s wide peaks. To keep dwell and cycle times constant across all peaks, each segment consisted of 30 analytes (60 transitions). For assessment, we injected extracts of spiked broccoli, cantaloupe, lemon, and sweet potato from the updated QuEChERS sample preparation method. Average recoveries (n = 72) were 70-120% for 144 of the pesticides, and reproducibilities were <20% RSD for all but 4 analytes. Also, detection limits were <5 ng/g for all but a few pesticides, depending on the matrix. In addition to high quality performance, the method gave excellent reliability and high sample throughput, including easy peak integration to obtain rapid results. Published by Elsevier B.V.
引用
收藏
页码:7039 / 7050
页数:12
相关论文
共 55 条
[1]   Gas chromatography-mass spectrometry with supersonic molecular beams [J].
Amirav, Aviv ;
Gordin, Alexander ;
Poliak, Marina ;
Fialkov, Alexander B. .
JOURNAL OF MASS SPECTROMETRY, 2008, 43 (02) :141-163
[2]   Evaluation of analyte protectants to improve gas chromatographic analysis of pesticides [J].
Anastassiades, M ;
Mastovská, K ;
Lehotay, SJ .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1015 (1-2) :163-184
[3]  
Anastassiades M, 2003, J AOAC INT, V86, P412
[4]  
ANASTASSIADES M, 2006, 6 EUR PEST RES WORKS
[5]  
[Anonymous], 2009, USDA National Nutrient Database for Standard Reference
[6]  
[Anonymous], SANCO106842009
[7]   Reduction of analysis time in gas chromatography Application of low-pressure gas chromatography-tandem mass spectrometry to the determination of pesticide residues in vegetables [J].
Arrebola, FJ ;
Vidal, JLM ;
González-Rodríguez, MJ ;
Garrido-Frenich, A ;
Morito, NS .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1005 (1-2) :131-141
[8]   Use of automated direct sample introduction with analyte protectants in the GC-MS analysis of pesticide residues [J].
Cajka, T ;
Mastovská, K ;
Lehotay, SJ ;
Hajslová, J .
JOURNAL OF SEPARATION SCIENCE, 2005, 28 (9-10) :1048-1060
[9]   Rapid analysis of multiple pesticide residues in fruit-based baby food using programmed temperature vaporiser injection-low-pressure gas chromatography-high-resolution time-of-flight mass spectrometry [J].
Cajka, Tomas ;
Hajslova, Jana ;
Lacina, Ondrej ;
Mastovska, Katerina ;
Lehotay, Steven J. .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1186 (1-2) :281-294
[10]   Fast gas chromatography-time-of-flight mass spectrometry of polychlorinated biphenyls and other environmental contaminants [J].
Cochran, JW .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2002, 40 (05) :254-268