Automation bias in medicine: The influence of automated diagnoses on interpreter accuracy and uncertainty when reading electrocardiograms

被引:55
作者
Bond, Raymond R. [1 ]
Novotny, Tomas [2 ,3 ]
Andrsova, Irena [2 ,3 ]
Koc, Lumir [2 ,3 ]
Sisakova, Martina [2 ,3 ]
Finlay, Dewar [1 ]
Guldenring, Daniel [1 ]
McLaughlin, James [1 ]
Peace, Aaron [4 ]
McGilligan, Victoria [5 ]
Leslie, Stephen J. [6 ]
Wang, Hui [1 ]
Malik, Marek [7 ,8 ]
机构
[1] Ulster Univ, Fac Comp & Engn, Newtownabbey, North Ireland
[2] Univ Hosp Brno, Dept Internal Med & Cardiol, Brno, Czech Republic
[3] Masaryk Univ, Fac Med, Brno, Czech Republic
[4] Altnagelvin Hosp, Western Hlth & Social Care Trust, Dept Cardiol, Derry, North Ireland
[5] Ulster Univ, C TRIC, Northern Ireland Ctr Stratified Med, Deny Londondeny, North Ireland
[6] Raigmore Hosp, Cardiac Unit, Inverness IV2 3UJ, Scotland
[7] St Pauls Cardiac Electrophysiol, London, England
[8] Imperial Coll London, London, England
关键词
12-LEAD ELECTROCARDIOGRAM; ELECTRODE MISPLACEMENT; TECHNOLOGY; SYSTEM;
D O I
10.1016/j.jelectrocard.2018.08.007
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Interpretation of the 12-lead Electrocardiogram (ECG) is normally assisted with an automated diagnosis (AD), which can facilitate an 'automation bias' where interpreters can be anchored. In this paper, we studied, 1) the effect of an incorrect AD on interpretation accuracy and interpreter confidence (a proxy for uncertainty), and 2) whether confidence and other interpreter features can predict interpretation accuracy using machine learning. Methods: This study analysed 9000 ECG interpretations from cardiology and non-cardiology fellows (CFs and non-CFs). One third of the ECGs involved no ADs, one third with ADs (half as incorrect) and one third had multiple ADs. Interpretations were scored and interpreter confidence was recorded for each interpretation and subsequently standardised using sigma scaling. Spearman coefficients were used for correlation analysis and C5.0 decision trees were used for predicting interpretation accuracy using basic interpreter features such as confidence, age, experience and designation. Results: Interpretation accuracies achieved by CFs and non-CFs dropped by 43.20% and 58.95% respectively when an incorrect AD was presented (p < 0.001). Overall correlation between scaled confidence and interpretation accuracy was higher amongst CFs. However, correlation between confidence and interpretation accuracy decreased for both groups when an incorrect AD was presented. We found that an incorrect AD disturbs the reliability of interpreter confidence in predicting accuracy. An incorrect AD has a greater effect on the confidence of non-CFs (although this is not statistically significant it is close to the threshold, p = 0.065). The best C5.0 decision tree achieved an accuracy rate of 64.67% (p < 0.001), however this is only 6.56% greater than the no information-rate. Conclusion: Incorrect ADs reduce the interpreter's diagnostic accuracy indicating an automation bias. Non-CFs tend to agree more with the ADs in comparison to CFs, hence less expert physicians are more effected by automation bias. Incorrect ADs reduce the interpreter's confidence and also reduces the predictive power of confidence for predicting accuracy (even more so for non-CFs). Whilst a statistically significant model was developed, it is difficult to predict interpretation accuracy using machine learning on basic features such as interpreter confidence, age, reader experience and designation. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:S6 / S11
页数:6
相关论文
共 19 条
  • [1] Assessing computerized eye tracking technology for gaining insight into expert interpretation of the 12-lead electrocardiogram: an objective quantitative approach
    Bond, R. R.
    Zhu, T.
    Finlay, D. D.
    Drew, B.
    Kligfield, P. D.
    Guldenring, D.
    Breen, C.
    Gallagher, A. G.
    Daly, M. J.
    Clifford, G. D.
    [J]. JOURNAL OF ELECTROCARDIOLOGY, 2014, 47 (06) : 895 - 906
  • [2] The effects of electrode misplacement on clinicians' interpretation of the standard 12-lead electrocardiogram
    Bond, R. R.
    Finlay, D. D.
    Nugent, C. D.
    Breen, C.
    Guldenring, D.
    Daly, M. J.
    [J]. EUROPEAN JOURNAL OF INTERNAL MEDICINE, 2012, 23 (07) : 610 - 615
  • [3] Human factors analysis of the CardioQuick Patch®: A novel engineering solution to the problem of electrode misplacement during 12-lead electrocardiogram acquisition
    Bond, Raymond R.
    Finlay, Dewar D.
    McLaughlin, James
    Guldenring, Daniel
    Cairns, Andrew
    Kennedy, Alan
    Deans, Robert
    Waldo, Albert L.
    Peace, Aaron
    [J]. JOURNAL OF ELECTROCARDIOLOGY, 2016, 49 (06) : 911 - 918
  • [4] Methods for presenting and visualising electrocardiographic data: From temporal signals to spatial imaging
    Bond, Raymond R.
    Finlay, Dewar D.
    Nugent, Chris D.
    Moore, George
    Guldenring, Daniel
    [J]. JOURNAL OF ELECTROCARDIOLOGY, 2013, 46 (03) : 182 - 196
  • [5] A simulation tool for visualizing and studying the effects of electrode misplacement on the 12-lead electrocardiogram
    Bond, Raymond R.
    Finlay, Dewar D.
    Nugent, Chris D.
    Moore, George
    Guldenring, Daniel
    [J]. JOURNAL OF ELECTROCARDIOLOGY, 2011, 44 (04) : 439 - 444
  • [6] A decision support system and rule-based algorithm to augment the human interpretation of the 12-lead electrocardiogram
    Cairns, Andrew W.
    Bond, Raymond R.
    Finlay, Dewar D.
    Guldenring, Daniel
    Badilini, Fabio
    Libretti, Guido
    Peace, Aaron J.
    Leslie, Stephen J.
    [J]. JOURNAL OF ELECTROCARDIOLOGY, 2017, 50 (06) : 781 - 786
  • [7] A computer-human interaction model to improve the diagnostic accuracy and clinical decision-making during 12-lead electrocardiogram interpretation
    Cairns, Andrew W.
    Bond, Raymond R.
    Finlay, Dewar D.
    Breen, Cathal
    Guldenring, Daniel
    Gaffney, Robert
    Gallagher, Anthony G.
    Peace, Aaron J.
    Henn, Pat
    [J]. JOURNAL OF BIOMEDICAL INFORMATICS, 2016, 64 : 93 - 107
  • [8] Canning A, 2018, J ELECTROCARDIOL, V51, pe8
  • [9] The IEEE Global Initiative for Ethical Considerations in Artificial Intelligence and Autonomous Systems
    Chatila, Raja
    Firth-Butterflied, Kay
    Havens, John C.
    Karachalios, Konstantinos
    [J]. IEEE ROBOTICS & AUTOMATION MAGAZINE, 2017, 24 (01) : 110 - 110
  • [10] Effects of electrode placement errors in the EASI-derived 12-lead electrocardiogram
    Finlay, Dewar D.
    Nugent, Chris D.
    Nelwan, Stefan P.
    Bond, Raymond R.
    Donnelly, Mark P.
    Guldenring, Daniel
    [J]. JOURNAL OF ELECTROCARDIOLOGY, 2010, 43 (06) : 606 - 611