Energy-efficient air conditioning system using a three-fluid heat exchanger for simultaneous and control

被引:27
作者
Liang, Chenjiyu [1 ]
Wang, Yuan [1 ]
Li, Xianting [1 ]
机构
[1] Tsinghua Univ, Sch Architecture, Dept Bldg Sci, Beijing Key Lab Indoor Air Qual Evaluat & Control, Beijing 100084, Peoples R China
关键词
Dehumidification; Room air conditioner; Dehumidifier; Three -fluid heat exchanger; Building energy efficiency; PUMP DEHUMIDIFIER; PERFORMANCE; CONSUMPTION; SIMULATION; OPERATION;
D O I
10.1016/j.enconman.2022.116236
中图分类号
O414.1 [热力学];
学科分类号
摘要
Room air conditioners are unable to simultaneously control the temperature and humidity of the air supply. Although temperature-regulating dehumidifiers can simultaneously control the temperature and humidity, they have complex refrigerant pipelines, and the heat exchanger exhibits air resistance when the reheat demand is low. This study proposes an air conditioning system for simultaneous temperature and humidity control, using a three-fluid heat exchanger. The supply air temperature is adjusted by changing the air volume ratio and cooling water flow rate through the three-fluid heat exchanger, which is used as the condenser. Free cooling can be realized by supplying low-temperature cooling water to treat the return air. Numerical models were built to simulate the performance of the devices in the system, and were validated by experimental results. The temperature-regulating performance and energy consumption under different conditions were numerically calculated using a case-studied air-conditioned room in Beijing. The results are summarized as follows: 1. The proposed strategy can regulate the supply air temperature over a wide range of temperatures. 2. Compared with those of the temperature-regulating dehumidifier system, the compressor and fan energy consumption of the proposed system are reduced by 19.1% and 15.5%, respectively, with a total energy-saving rate of 15.8% in the cooling season. 3. Compared with those of the room air conditioner system, the compressor energy consumption of the proposed system is reduced by 11.5%, and the energy-saving rate of the entire system is 6.3%. The initial investment of the proposed system does not increase significantly compared with conventional systems, and the refrigerant pipeline and valves can be simplified, resulting in acceptable economic performance for the proposed system.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Performance study of desiccant coated heat exchanger air conditioning system in winter
    Ge, T. S.
    Dai, Y. J.
    Wang, R. Z.
    ENERGY CONVERSION AND MANAGEMENT, 2016, 123 : 559 - 568
  • [22] An energy-efficient air-conditioning system with an exhaust fan integrated with a supply fan
    Wan, J. W.
    Zhang, W. J.
    Zhang, W. M.
    ENERGY AND BUILDINGS, 2009, 41 (12) : 1299 - 1305
  • [23] The impact of ambient heat ingression on performance of cryogenic three-fluid cross-flow compact heat exchanger
    Aasi, Harpreet Kaur
    Mishra, Manish
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2022, 176
  • [24] Intelligent control for energy conservation of air conditioning system in manufacturing systems
    Wang, Kung-Jeng
    Dagne, Teshome Bekele
    Lin, Chiuhsiang Joe
    Woldegiorgis, Bereket Haile
    Hong-Phuc Nguyen
    ENERGY REPORTS, 2021, 7 : 2125 - 2137
  • [25] Experimental study on a pulsating heat pipe heat exchanger for energy saving in air-conditioning system in summer
    Yang, Honghai
    Wang, Jun
    Wang, Ning
    Yang, Fengchang
    ENERGY AND BUILDINGS, 2019, 197 : 1 - 6
  • [26] Applicability of a liquid-desiccant air-conditioning system in energy-efficient buildings with high latent load
    Lee, Jae-Hee
    Cheon, Seong-Yong
    Lee, Soo-Jin
    Cho, Hye-Jin
    Jeong, Jae-Weon
    JOURNAL OF BUILDING ENGINEERING, 2023, 78
  • [27] Energy and Exergy Analyses of an Air Membrane Heat and Mass Exchanger for Air Conditioning Applications
    Al-Sulaiman, Fahad A.
    JOURNAL OF ENERGY ENGINEERING, 2017, 143 (05)
  • [28] Investigation of heat pipe heat exchanger effectiveness and energy saving in air conditioning systems using silver nanofluid
    Firouzfar, E.
    Soltanieh, M.
    Noie, S. H.
    Saidi, M. H.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2012, 9 (04) : 587 - 594
  • [29] Transient Behavior of Three-Fluid Cross-Flow Heat Exchanger Under the Influence of Temperature Nonuniformity
    Aasi, Harpreet Kaur
    Mishra, Manish
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2018, 10 (06)
  • [30] Experimental investigation on combined flow and temperature non-uniformity for three-fluid compact heat exchanger with cross flow configuration
    Aasi, Harpreet Kaur
    Mishra, Manish
    EXPERIMENTAL HEAT TRANSFER, 2024,