A Sandwich Electrochemical Immunosensor Using Magnetic DNA Nanoprobes for Carcinoembryonic Antigen

被引:38
作者
Gan, Ning [1 ]
Jia, Liyong [1 ,2 ]
Zheng, Lei [2 ]
机构
[1] Ningbo Univ, Fac Mat Sci & Chem Engn, State Key Lab Base Novel Funct Mat & Preparat Sci, Ningbo 315211, Zhejiang, Peoples R China
[2] So Med Univ, Nanfang Hosp, Clin Lab Ctr, Guangzhou 510515, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
chitosan/DNA/Fe3O4/ZrO2; magnetic nanoparticle-based electrochemical immunoassay; carcinoembryonic antigen; sandwich electrochemical immunosensor; AMPEROMETRIC IMMUNOSENSOR; NANOPARTICLES; IMMUNOASSAY; ENZYME; LAYER; ZIRCONIA; FILMS;
D O I
10.3390/ijms12117410
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A novel magnetic nanoparticle-based electrochemical immunoassay of carcinoembryonic antigen (CEA) was designed as a model using CEA antibody-functionalized magnetic beads [DNA/Fe3O4/ZrO2; Fe3O4 (core)/ZrO2 (shell) nano particles (ZMPs)] as immunosensing probes. To design the immunoassay, the CEA antibody and O-phenylenediamine (OPD) were initially immobilized on a chitosan/nano gold composite membrane on a glassy carbon electrode (GCE/CS-nano Au), which was used for CEA recognition. Then, horseradish peroxidase (HRP)-labeled anti-CEA antibodies (HRP-CEA Ab(2)) were bound to the surface of the synthesized magnetic ZMP nanoparticles as signal tag. Thus, the sandwich-type immune complex could be formed between secondary antibody (Ab(2)) modified DNA/ZMPs nanochains tagged by HRP and GCE/CS-nano Au. Unlike conventional nanoparticle-based electrochemical immunoassays, the recognition elements of this immunoassay included both electron mediators and enzyme labels, which obviously simplifies the electrochemical measurement process. The sandwich-type immunoassay format was used for online formation of the immunocomplex of CEA captured in the detection cell with an external magnet. The electrochemical signals derived from HRP during the reduction of H2O2 with OPD as electron mediator were measured. The method displayed a high sensitivity for CEA detection in the range of 0.008-200 ng/mL, with a detection limit of 5 pg/mL (estimated at a signal-to-noise ratio of 3). The precision, reproducibility, and stability of the immunoassay were good. The use of the assay was evaluated with clinical serum samples, and the results were in excellent accordance with those obtained using the standard enzyme-linked immunosorbent assay (ELISA) method. Thus, the magnetic nanoparticle-based assay format is a promising approach for clinical applications, and it could be further developed for the detection of other biomarkers in cancer diagnosis.
引用
收藏
页码:7410 / 7423
页数:14
相关论文
共 30 条
[1]  
CI YX, 1995, ANAL CHIM ACTA, V300, P273
[2]   Fabrication of a novel electrochemical immunosensor based on the gold nanoparticles/colloidal carbon nanosphere hybrid material [J].
Cui, Rongjing ;
Zhu, Jun-Jie .
ELECTROCHIMICA ACTA, 2010, 55 (27) :7814-7817
[3]   Functionalized Graphene Oxide as a Nanocarrier in a Multienzyme Labeling Amplification Strategy for Ultrasensitive Electrochemical Immunoassay of Phosphorylated p53 (S392) [J].
Du, Dan ;
Wang, Limin ;
Shao, Yuyan ;
Wang, Jun ;
Engelhard, Mark H. ;
Lin, Yuehe .
ANALYTICAL CHEMISTRY, 2011, 83 (03) :746-752
[4]   Sensitive Immunosensor for Cancer Biomarker Based on Dual Signal Amplification Strategy of Graphene Sheets and Multienzyme Functionalized Carbon Nanospheres [J].
Du, Dan ;
Zou, Zhexiang ;
Shin, Yongsoon ;
Wang, Jun ;
Wu, Hong ;
Engelhard, Mark H. ;
Liu, Jun ;
Aksay, Ilhan A. ;
Lin, Yuehe .
ANALYTICAL CHEMISTRY, 2010, 82 (07) :2989-2995
[5]   Magnetic-controlled non-competitive enzyme-linked voltammetric immunoassay for carcinoembryonic antigen [J].
Fu, Xiao-Hong .
BIOCHEMICAL ENGINEERING JOURNAL, 2008, 39 (02) :267-275
[6]   Synthesis and characterization of new zirconia-based polymeric cation-exchange stationary phases for high-performance liquid chromatography of proteins [J].
Hu, Y ;
Carr, PW .
ANALYTICAL CHEMISTRY, 1998, 70 (09) :1934-1942
[7]   Porous zirconia: A new support material for enzyme immobilization [J].
Huckel, M ;
Wirth, HJ ;
Hearn, MTW .
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 1996, 31 (3-4) :165-179
[8]   Cancer Cells in Transit: The Vascular Interactions of Tumor Cells [J].
Konstantopoulos, Konstantinos ;
Thomas, Susan N. .
ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2009, 11 :177-202
[9]   2ND DERIVATIVE SYNCHRONOUS SCANNING FLUORESCENCE SPECTROMETRY AS A SENSITIVE DETECTION TECHNIQUE IN IMMUNOASSAYS - APPLICATION TO THE DETERMINATION OF ALPHA-FETOPROTEIN [J].
LIANIDOU, ES ;
IOANNOU, PC ;
SACHARIDOU, E .
ANALYTICA CHIMICA ACTA, 1994, 290 (1-2) :159-165
[10]   A novel immunosensor for carcinoembryonic antigen based on poly(diallyldimethylammonium chloride) protected prussian blue nanoparticles and double-layer nanometer-sized gold particles [J].
Lv, Ping ;
Min, Ligen ;
Yuan, Ruo ;
Chai, Yaqin ;
Chen, Shihong .
MICROCHIMICA ACTA, 2010, 171 (3-4) :297-304