Electrocatalytic behavior of glassy carbon electrodes modified with multiwalled carbon nanotubes and cobalt phthalocyanine for selective analysis of dopamine in presence of ascorbic acid

被引:93
|
作者
Moraes, Fernando Cruz [2 ]
Cabral, Murilo F. [1 ]
Machado, Sergio A. S. [1 ]
Mascaro, Lucia H. [2 ]
机构
[1] Univ Sao Paulo, Inst Quim Sao Carlos, BR-13560970 Sao Carlos, SP, Brazil
[2] Univ Fed Sao Carlos, Dept Quim, BR-13560970 Sao Carlos, SP, Brazil
关键词
carbon nanotubes; cobalt phthalocyanine; dopamine; ascorbic acid; modified electrode;
D O I
10.1002/elan.200704107
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work describes the development, electrochemical characterization and utilization of a cobalt phthalocyanine modified carbon nanotube electrode for the quantitative determination of dopamine in 0.2 mol L-1 phosphate buffer contaminated with high concentration of ascorbic acid. The electrode surface was analyzed by cyclic voltammetry and electrochemical impedance spectroscopy which showed a modified surface presenting a charge transfer resistance of 500 Omega, against the 16.46 k Omega value found for the bare glassy carbon surface. A pseudo rate constant value of 5.4 x 10(-4) cm s(-1) for dopamine oxidation was calculated. Voltammetric experiments showed a shift of the peak potential of DA oxidation to less positive value at 390 mV as compared with that of a bare GC electrode at 570 mV. The electrochemical determination of dopamine, in presence of ascorbic acid in concentrations up to 0.1 mol L-1 by differential pulse voltarnmetry, yielded a detection limit as low as 2.56 x 10(-7) mol L-1.
引用
收藏
页码:851 / 857
页数:7
相关论文
共 50 条
  • [1] Highly Selective Determination of Dopamine in the Presence of Ascorbic Acid and Serotonin at Glassy Carbon Electrodes Modified with Carbon Nanotubes Dispersed in Polyethylenimine
    Rodriguez, Marcela C.
    Rubianes, Maria D.
    Rivas, Gustavo A.
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2008, 8 (11) : 6003 - 6009
  • [2] Glassy carbon electrodes modified with multiwalled carbon nanotubes for the determination of ascorbic acid by square-wave voltammetry
    Kumar, Sushil
    Vicente-Beckett, Victoria
    BEILSTEIN JOURNAL OF NANOTECHNOLOGY, 2012, 3 : 388 - 396
  • [3] Selective determination of dopamine in the presence of ascorbic acid at porous-carbon-modified glassy carbon electrodes
    Song, Shuqing
    Gao, Qiuming
    Xia, Kaisheng
    Gao, Lu
    ELECTROANALYSIS, 2008, 20 (11) : 1159 - 1166
  • [4] The electrocatalytic oxidation of dopamine and ascorbic acid on a glassy carbon electrode modified with the carbon nanotube
    He, CX
    Zhao, CZ
    Tang, ZN
    Qiu, JS
    Wang, LD
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2003, 31 (08) : 958 - 960
  • [5] Highly selective determination of uric acid in the presence of ascorbic acid at glassy carbon electrodes modified with carbon nanotubes dispersed in polylysine
    Rodriguez, Marcela C.
    Sandoval, Jose
    Galicia, Laura
    Gutierrez, Silvia
    Rivas, Gustavo A.
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 134 (02) : 559 - 565
  • [6] An electrochemical biosensor for determination of ascorbic acid by cobalt (II) phthalocyanine-multi-walled carbon nanotubes modified glassy carbon electrode
    Zuo, Xia
    Zhang, Hui
    Li, Nan
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 161 (01): : 1074 - 1079
  • [7] Selective Detection of Dopamine in Presence of Ascorbic Acid by Use of Glassy-Carbon Electrode Modified with Amino-β-Cyclodextrin and Carbon Nanotubes
    Gaied, Aymen
    Jaballah, Nejmeddine
    Tounsi, Moncef
    Braiek, Mohamed
    Jaffrezic-Renault, Nicole
    Majdoub, Mustapha
    ELECTROANALYSIS, 2014, 26 (12) : 2747 - 2753
  • [8] Synergistic Effect of Graphene and Multiwalled Carbon Nanotubes on a Glassy Carbon Electrode for Simultaneous Determination of Uric Acid and Dopamine in the Presence of Ascorbic Acid
    He, Sijing
    Yu, Yanyan
    Chen, Zuanguang
    Shi, Qiujia
    Zhang, Lin
    ANALYTICAL LETTERS, 2015, 48 (02) : 248 - 258
  • [9] ELECTROCATALYTIC OXIDATION OF ASCORBIC ACID AT POLYANILINE FILM MODIFIED GLASSY CARBON ELECTRODES
    Dong Shaojun
    Song Fayi
    ACTA PHYSICO-CHIMICA SINICA, 1992, 8 (01) : 82 - 86
  • [10] Electrochemical behavior of modified electrodes with carbon nanotubes and nanofibers: Application to the sensitive measurement of uric acid in the presence of ascorbic acid
    Zhang, Hongfang
    Zhang, Jing
    Zheng, Jianbin
    MEASUREMENT, 2015, 59 : 177 - 183