Novel Algorithm for Radon Real-Time Measurements with a Pixelated Detector

被引:2
作者
Rizzo, Alessandro [1 ]
Cardellini, Francesco [2 ]
Poggi, Claudio [3 ]
Borra, Enrico [1 ]
Ciciani, Luca [1 ]
Narici, Livio [4 ]
Sperandio, Luciano [1 ]
Vilardi, Ignazio [1 ]
机构
[1] Italian Natl Agcy New Technol Energy & Sustainabl, Radiat Protect Inst IRP, Via Anguillarese 301, I-00123 Rome, Italy
[2] Italian Natl Agcy New Technol Energy & Sustainabl, Natl Inst Ionizing Radiat Metrol INMRI, Via Anguillarese 301, I-00123 Rome, Italy
[3] Italian Natl Agcy New Technol Energy & Sustainabl, Radiat Protect Inst IRP, Via Enrico Fermi 45, I-00044 Rome, Italy
[4] Univ Roma Tor Vergata, Phys Dept, Via Ric Sci 1, I-00133 Rome, Italy
关键词
radon; real-time measurements; TimePix; MediPix; pattern recognition algorithm; LUCAS CELL; INDOOR; AIR;
D O I
10.3390/s22020516
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Nowadays, radon gas exposure is considered one of the main health concerns for the population because, by carrying about half the total dose due to environmental radioactivity, it is the second cause of lung cancer after smoking. Due to a relatively long half-life of 3.82 days, the chemical inertia and since its parent Ra-226 is largely diffuse on the earth's crust and especially in the building materials, radon can diffuse and potentially saturate human habitats, with a concentration that can suddenly change during the 24 h day depending on temperature, pressure, and relative humidity. For such reasons, 'real-time' measurements performed by an active detector, possibly of small dimensions and a handy configuration, can play an important role in evaluating the risk and taking the appropriate countermeasures to mitigate it. In this work, a novel algorithm for pattern recognition was developed to exploit the potentialities of silicon active detectors with a pixel matrix structure to measure radon through the alpha emission, in a simple measurement configuration, where the device is placed directly in air with no holder, no collection filter or electrostatic field to drift the radon progenies towards the detector active area. This particular measurement configuration (dubbed as bare) requires an alpha/beta-discrimination method that is not based on spectroscopic analysis: as the gas surrounds the detector the alpha particles are emitted at different distances from it, so they lose variable energy amount in air depending on the traveled path-length which implies a variable deposited energy in the active area. The pixels matrix structure allows overcoming this issue because the interaction of alpha, beta and gamma particles generate in the active area of the detector clusters (group of pixels where a signal is read) of different shape and energy dispersion. The novel algorithm that exploits such a phenomenon was developed using a pixelated silicon detector of the TimePix family with a compact design. An alpha (Am-241) and a beta (Sr-90) source were used to calibrate the algorithm and to evaluate its performances in terms of beta rejection capability and alpha recognition efficiency. Successively, the detector was exposed to different radon concentrations at the ENEA-INMRI radon facility in 'bare' configuration, in order to check the linearity of the device response over a radon concentration range. The results for this technique are presented and discussed, highlighting the potential applications especially the possibility to exploit small and handy detectors to perform radon active measurements in the simplest configuration.
引用
收藏
页数:15
相关论文
共 28 条
  • [1] Indoor radon measurement with The Lucas cell technique
    Abbady, A
    Abbady, AGE
    Michel, R
    [J]. APPLIED RADIATION AND ISOTOPES, 2004, 61 (06) : 1469 - 1475
  • [2] A PULSE-COUNTING IONIZATION-CHAMBER FOR MEASURING THE RADON CONCENTRATION IN AIR
    BALTZER, P
    GORSTEN, KG
    BACKLIN, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 317 (1-2) : 357 - 364
  • [3] Measurement of radon progenies using the Timepix detector
    Bulanek, Boris
    Jilek, Karel
    Cermak, Pavel
    [J]. RADIATION PROTECTION DOSIMETRY, 2014, 160 (1-3) : 184 - 187
  • [4] Real-time measurements of radon activity with the Timepix-based RADONLITE and RADONPIX detectors
    Caresana, M.
    Garlati, L.
    Murtas, F.
    Romano, S.
    Severino, C. T.
    Silari, M.
    [J]. JOURNAL OF INSTRUMENTATION, 2014, 9
  • [5] Degu Belete Guadie, 2021, J Oncol, V2021, P6659795, DOI 10.1155/2021/6659795
  • [6] Estimation of indoor radon levels using etched track detector
    El-Badry, Basma A.
    Al-Naggar, Tayseer, I
    [J]. JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2018, 11 (04) : 355 - 360
  • [7] AN OVERVIEW OF INSTRUMENTATION FOR MEASURING ENVIRONMENTAL RADON AND RADON PROGENY
    GEORGE, AC
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) : 892 - 901
  • [8] Evaluation of the radon interference on the performance of the portable monitoring air pump for radioactive aerosols (MARE)
    Glavic-Cindro, Denis
    Brodnik, Drago
    Cardellini, Francesco
    De Felice, Pierino
    Ponikvar, Dugan
    Vencelj, Matjaz
    Petrovic, Toni
    [J]. APPLIED RADIATION AND ISOTOPES, 2018, 134 : 439 - 445
  • [9] Grangia C., 2014, P SCI POS X LASNPA, V3, P10
  • [10] Application of the Electret in Alpha Radiation Sensor to Measure the Concentration of Radon in Selected Ambient Conditions
    Gubanski, Adam
    Kupracz, Jan
    Kostyla, Pawel
    Kaczorowska, Dominika
    Wrobel, Jerzy
    [J]. JOURNAL OF SENSORS, 2019, 2019