Blend uniformity evaluation during continuous mixing in a twin screw granulator by in-line NIR using a moving F-test

被引:28
作者
Fonteyne, Margot [1 ]
Vercruysse, Jurgen [2 ]
De Leersnyder, Fien [1 ]
Besseling, Rut [3 ]
Gerich, Ad [3 ]
Oostra, Wim [3 ]
Remon, Jean Paul [2 ]
Vervaet, Chris [2 ]
De Beer, Thomas [1 ]
机构
[1] Univ Ghent, Lab Pharmaceut Proc Analyt Technol, Ottergemsesteenweg 460, Ghent, Belgium
[2] Univ Ghent, Lab Pharmaceut Technol, Ottergemsesteenweg 460, Ghent, Belgium
[3] Merck, Oss, Netherlands
关键词
Continuous blending; Process Analytical Technology; Near infrared spectroscopy; Moving F-test; alpha- and beta-error control; Blend uniformity; NEAR-INFRARED SPECTROSCOPY; PROCESS ANALYTICAL TECHNOLOGY; PHARMACEUTICAL POWDER BLENDS; END-POINT DETECTION; BOHLE BIN-BLENDER; PART II; AUTOMATED-SYSTEM; DRUG CONTENT; HOMOGENEITY; CALIBRATION;
D O I
10.1016/j.aca.2016.07.020
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study focuses on the twin screw granulator of a continuous from-powder-to-tablet production line. Whereas powder dosing into the granulation unit is possible from a container of preblended material, a truly continuous process uses several feeders (each one dosing an individual ingredient) and relies on a continuous blending step prior to granulation. The aim of the current study was to investigate the in-line blending capacity of this twin screw granulator, equipped with conveying elements only. The feasibility of in-line NIR (SentroPAT, Sentronic GmbH, Dresden, Germany) spectroscopy for evaluating the blend uniformity of powders after the granulator was tested. Anhydrous theophylline was used as a tracer molecule and was blended with lactose monohydrate. Theophylline and lactose were both fed from a different feeder into the twin screw granulator barrel. Both homogeneous mixtures and mixing experiments with induced errors were investigated. The in-line spectroscopic analyses showed that the twin screw granulator is a useful tool for in-line blending in different conditions. The blend homogeneity was evaluated by means of a novel statistical method being the moving F-test method in which the variance between two blocks of collected NIR spectra is evaluated. The alpha- and beta-error of the moving F-test are controlled by using the appropriate block size of spectra. The moving F-test method showed to be an appropriate calibration and maintenance free method for blend homogeneity evaluation during continuous mixing. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:213 / 223
页数:11
相关论文
共 62 条
[1]   Characterizing mixing and lubrication in the Bohle Bin blender [J].
Arratia, PE ;
Duong, NH ;
Muzzio, FJ ;
Godbole, P ;
Lange, A ;
Reynolds, S .
POWDER TECHNOLOGY, 2006, 161 (03) :202-208
[2]   Real-time monitoring of powder mixing in a convective blender using non-invasive reflectance NIR spectrometry [J].
Bellamy, Luke J. ;
Nordon, Alison ;
Littlejohn, David .
ANALYST, 2008, 133 (01) :58-64
[3]   Cohesive, multicomponent, dense powder flow characterization by NIR [J].
Benedetti, C. ;
Abatzoglou, N. ;
Simard, J.-S. ;
McDermott, L. ;
Leonarda, G. ;
Cartilier, L. .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2007, 336 (02) :292-301
[4]   Quantitative in-line monitoring of powder blending by near infrared reflection spectroscopy [J].
Berntsson, O ;
Danielsson, LG ;
Lagerholm, B ;
Folestad, S .
POWDER TECHNOLOGY, 2002, 123 (2-3) :185-193
[5]   Quantitative determination of content in binary powder mixtures using diffuse reflectance near infrared spectrometry and multivariate analysis [J].
Berntsson, O ;
Danielsson, LG ;
Johansson, MO ;
Folestad, S .
ANALYTICA CHIMICA ACTA, 2000, 419 (01) :45-54
[6]   An efficient, maintenance free and approved method for spectroscopic control and monitoring of blend uniformity: The moving F-test [J].
Besseling, Rut ;
Damen, Michiel ;
Thanh Tran ;
Thanh Nguyen ;
van den Dries, Kaspar ;
Oostra, Wim ;
Gerich, Ad .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2015, 114 :471-481
[7]   Near-infrared spectroscopy in the pharmaceutical industry [J].
Blanco, M ;
Coello, J ;
Iturriaga, H ;
Maspoch, S ;
de la Pezuela, C .
ANALYST, 1998, 123 (08) :135R-150R
[8]   Comparison of FT-NIR transmission and UV-vis spectrophotometry to follow the mixing kinetics and to assay low-dose tablets containing riboflavin [J].
Bodson, C. ;
Dewe, W. ;
Hubert, Ph. ;
Delattre, L. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 41 (03) :783-790
[9]   Near infrared and Raman spectroscopy for the in-process monitoring of pharmaceutical production processes [J].
De Beer, T. ;
Burggraeve, A. ;
Fonteyne, M. ;
Saerens, L. ;
Remon, J. P. ;
Vervaet, C. .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2011, 417 (1-2) :32-47
[10]   A homogeneity study using NIR spectroscopy: Tracking magnesium stearate in Bohle bin-blender [J].
Duong, NH ;
Arratia, P ;
Muzzio, F ;
Lange, A ;
Timmermans, J ;
Reynolds, S .
DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 2003, 29 (06) :679-687