Comparison of manual pulse palpation, cardiac ultrasonography and Doppler ultrasonography to check the pulse in cardiopulmonary arrest patients

被引:44
作者
Zengin, Suat [1 ]
Gumusboga, Hasan [1 ]
Sabak, Mustafa [1 ]
Eren, Sevki Hakan [1 ]
Altunbas, Gokhan [2 ]
Al, Behcet [1 ]
机构
[1] Gaziantep Univ, Dept Emergency Med, Sch Med, Gaziantep, Turkey
[2] Gaziantep Univ, Sch Med, Dept Cardiol, Gaziantep, Turkey
关键词
Cardiopulmonary arrest; Pulse check; Cardiac ultrasonography; Doppler ultrasonography; OF-CARE ULTRASOUND; LIFE-SUPPORT; CAROTID PULSE; RESUSCITATION; EMERGENCY; ECHOCARDIOGRAPHY; SONOGRAPHY; ACCURACY; ECHO; 1ST;
D O I
10.1016/j.resuscitation.2018.09.018
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: For health professionals, the absence of pulse checked by manual palpation is a primary indicator for initiating chest compressions in patients considered to have cardiopulmonary arrest (CA). However, using a pulse check to evaluate perfusion during CA may be associated with some risks of its own. Our objective was to compare the efficiency of cardiac ultrasonography (CUSG), Doppler ultrasonography (DUSG), and manual pulse palpation methods to check the pulse in CA patients. Material and methods: This study was prospectively performed in 137 patients older than 16 years of age who underwent cardiopulmonary resuscitation (CPR). CUSG, DUSG, and manual pulse palpation were practiced simultaneously as suggested in the relevant guidelines. Findings of the patients were recorded at the first min, at min 15 and at the end of CPR. SPSS 18.0 was used for statistical analysis. Findings: A total of 72.3% (n = 99) of the cardiopulmonary arrest incidents occurred out-of-hospital. CUSG (4.76 +/- 2.19, 4.33 +/- 2.17, and 3.68 +/- 2.14 s), DUSG (9.59 +/- 2.37, 8.22 +/- 2.86, and 7.60 +/- 2.83 s), and manual pulse palpation (10.76 +/- 1.03, 9.72 +/- 3.01, and 9.29 +/- 3.36 s) measurements of the first, second, and last inspections were detected, respectively. The false negative rates (100%, 28%, and 0%) and false positive rates (5.3%, 3.5%, and 0%) of manual pulse palpation the first, second, and last inspections were calculated, respectively, as well. Conclusion: The use of real-time CUSG during resuscitation provides a substantial contribution to the resuscitation team. CUSG will allow earlier and more accurate detection of pulse than manual pulse palpation and DUSG.
引用
收藏
页码:59 / 64
页数:6
相关论文
共 26 条
[1]   Carotid Doppler blood flow measurement during cardiopulmonary resuscitation is feasible: A first in man study [J].
Adedipe, Adeyinka A. ;
Fly, Deborah L. ;
Schwitz, Scott D. ;
Jorgenson, Dawn B. ;
Duric, Haris ;
Sayre, Michael R. ;
Nichol, Graham .
RESUSCITATION, 2015, 96 :121-125
[2]   Comparison of sequential and simultaneous breathing and pulse check by healthcare professionals during simulated scenarios [J].
Albarran, JW ;
Moule, P ;
Gilchrist, M ;
Soar, J .
RESUSCITATION, 2006, 68 (02) :243-249
[3]   Skills of lay people in checking the carotid pulse [J].
Bahr, J ;
Klingler, H ;
Panzer, W ;
Rode, H ;
Kettler, D .
RESUSCITATION, 1997, 35 (01) :23-26
[4]   Outcome in cardiac arrest patients found to have cardiac standstill on the bedside emergency department echocardiogram [J].
Blaivas, M ;
Fox, JC .
ACADEMIC EMERGENCY MEDICINE, 2001, 8 (06) :616-621
[5]   Focused echocardiographic evaluation in life support and pen-resuscitation of emergency patients: A prospective trial [J].
Breitkreutz, Raoul ;
Price, Susanna ;
Steiger, Holger V. ;
Seeger, Florian H. ;
Ilper, Hendrik ;
Ackermann, Hanns ;
Rudolph, Marcus ;
Uddin, Shahana ;
Weigand, Markus A. ;
Mueller, Edgar ;
Walcher, Felix .
RESUSCITATION, 2010, 81 (11) :1527-1533
[6]   Point-of-care ultrasound use in patients with cardiac arrest is associated prolonged cardiopulmonary resuscitation pauses: A prospective cohort study [J].
Clattenburg, Eben J. ;
Wroe, Peter ;
Brown, Stephen ;
Gardner, Kevin ;
Losonczy, Lia ;
Singh, Amandeep ;
Nagdev, Arun .
RESUSCITATION, 2018, 122 :65-68
[7]   Checking the carotid pulse check: Diagnostic accuracy of first responders in patients with and without a pulse [J].
Eberle, B ;
Dick, WF ;
Schneider, T ;
Wisser, G ;
Doetsch, S ;
Tzanova, I .
RESUSCITATION, 1996, 33 (02) :107-116
[8]   Emergency department point-of-care ultrasound in out-of-hospital and in-ED cardiac arrest [J].
Gaspari, Romolo ;
Weekes, Anthony ;
Adhikari, Srikar ;
Noble, Vicki E. ;
Nomura, Jason T. ;
Theodoro, Daniel ;
Woo, Michael ;
Atkinson, Paul ;
Blehar, David ;
Brown, Samuel M. ;
Caffery, Terrell ;
Douglass, Emily ;
Fraser, Jacqueline ;
Haines, Christine ;
Lam, Samuel ;
Lanspa, Michael ;
Lewis, Margaret ;
Liebmann, Otto ;
Limkakeng, Alexander ;
Lopez, Fernando ;
Platz, Elke ;
Mendoza, Michelle ;
Minnigan, Hal ;
Moore, Christopher ;
Novik, Joseph ;
Rang, Louise ;
Scruggs, Will ;
Raio, Christopher .
RESUSCITATION, 2016, 109 :33-39
[9]   An evaluation of echo in life support (ELS): is it feasible? What does it add? [J].
Hayhurst, C. ;
Lebus, C. ;
Atkinson, P. R. ;
Kendall, R. ;
Madan, R. ;
Talbot, J. ;
Ross, P. ;
Lewis, D. .
EMERGENCY MEDICINE JOURNAL, 2011, 28 (02) :119-121
[10]   Ultrasound use during cardiopulmonary resuscitation is associated with delays in chest compressions [J].
in 't Veld, Maite A. Huis ;
Allison, Michael G. ;
Bostick, David S. ;
Fisher, Kiondra R. ;
Goloubeva, Olga G. ;
Witting, Michael D. ;
Winters, Michael E. .
RESUSCITATION, 2017, 119 :95-98