Harmonic analysis of a three-phase diode bridge rectifier based on sampled-data model

被引:50
|
作者
Lian, K. L. [1 ]
Perkins, Brian K. [2 ]
Lehn, P. W. [1 ]
机构
[1] Univ Toronto, Dept Elect & Comp Engn, Toronto, ON M5S 3G4, Canada
[2] Hatch Ltd, Mississauga, ON L5K 2R7, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
continuous conduction mode (CCM); diode bridge rectifier; discontinuous conduction mode (DCM); harmonics; steady-state analysis;
D O I
10.1109/TPWRD.2008.917671
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a time domain method to analyze the three phase rectifier with capacitor output filter. As demonstrated in the paper, the proposed method analytically evaluates harmonics, and obtains exact switching functions by iteratively solving for the switching instants. An analytical Jacobian of the mismatch equations is obtained to ensure a quadratic convergence rate for the iteration process. It is also demonstrated that a unified approach exists to analyze converters operating in the continuous conduction mode and discontinuous conduction mode. One potential application of the proposed model is to incorporate it into a harmonic power flow program to yield improved accuracy.
引用
收藏
页码:1088 / 1096
页数:9
相关论文
共 42 条