Lightweight, compact, and high-performance 3T MR system for imaging the brain and extremities

被引:77
作者
Foo, Thomas K. F. [1 ]
Laskaris, Evangelos [1 ]
Vermilyea, Mark [1 ]
Xu, Minfeng [1 ]
Thompson, Paul [1 ]
Conte, Gene [1 ]
Van Epps, Christopher [1 ]
Immer, Christopher [1 ]
Lee, Seung-Kyun [1 ,2 ]
Tan, Ek T. [1 ]
Graziani, Dominic [1 ]
Mathieu, Jean-Baptise [3 ]
Hardy, Christopher J. [1 ]
Schenck, John F. [1 ]
Fiveland, Eric [1 ]
Stautner, Wolfgang [1 ]
Ricci, Justin [1 ]
Piel, Joseph [1 ]
Park, Keith [1 ]
Hua, Yihe [1 ]
Bai, Ye [1 ]
Kagan, Alex [1 ]
Stanley, David [5 ]
Weavers, Paul T. [4 ,5 ]
Gray, Erin [4 ]
Shu, Yunhong [4 ]
Frick, Matthew A. [4 ]
Campeau, Norbert G. [4 ]
Trzasko, Joshua [4 ]
Huston, John, III [4 ]
Bernstein, Matt A. [4 ]
机构
[1] GE Global Res, 1 Res Circle, Niskayuna, NY 12309 USA
[2] Sungkyunkwan Univ, Dept Biomed Engn, Suwon, South Korea
[3] GE Healthcare, Florence, SC USA
[4] Mayo Clin, Dept Radiol, Rochester, MN USA
[5] GE Healthcare, Waukesha, WI USA
关键词
PERIPHERAL-NERVE STIMULATION; TRANSVERSE GRADIENT COILS; CONCOMITANT FIELDS; HEAD; DISTORTION; DIFFUSION; DESIGN; LIMITS; FMRI; BODY;
D O I
10.1002/mrm.27175
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To build and evaluate a small-footprint, lightweight, high-performance 3T MRI scanner for advanced brain imaging with image quality that is equal to or better than conventional whole-body clinical 3T MRI scanners, while achieving substantial reductions in installation costs. Methods: A conduction-cooled magnet was developed that uses less than 12 liters of liquid helium in a gas-charged sealed system, and standard NbTi wire, and weighs approximately 2000 kg. A 42-cm inner-diameter gradient coil with asymmetric transverse axes was developed to provide patient access for head and extremity exams, while minimizing magnet-gradient interactions that adversely affect image quality. The gradient coil was designed to achieve simultaneous operation of 80-mT/m peak gradient amplitude at a slew rate of 700 T/m/s on each gradient axis using readily available 1-MVA gradient drivers. Results: In a comparison of anatomical imaging in 16 patients using T2-weighted 3D fluid-attenuated inversion recovery (FLAIR) between the compact 3T and whole-body 3T, image quality was assessed as equivalent to or better across several metrics. The ability to fully use a high slew rate of 700 T/m/s simultaneously with 80-mT/m maximum gradient amplitude resulted in improvements in image quality across EPI, DWI, and anatomical imaging of the brain. Conclusions: The compact 3T MRI system has been in continuous operation at the Mayo Clinic since March 2016. To date, over 200 patient studies have been completed, including 96 comparison studies with a clinical 3T whole-body MRI. The increased gradient performance has reliably resulted in consistently improved image quality.
引用
收藏
页码:2232 / 2245
页数:14
相关论文
共 50 条
[41]   A high-resolution multi-shell 3T diffusion magnetic resonance imaging dataset as part of the Amsterdam Ultra-high field adult lifespan database (AHEAD) [J].
Keuken, Max C. ;
Liebrand, Luka C. ;
Bazin, Pierre-Louis ;
Alkemade, Anneke ;
van Berendonk, Nikita ;
Groot, Josephine M. ;
Isherwood, Scott J. S. ;
Kemp, Sarah ;
Lute, Nicky ;
Mulder, Martijn J. ;
Trutti, Anne C. ;
Caan, Matthan W. A. ;
Forstmann, Birte U. .
DATA IN BRIEF, 2022, 42
[42]   Feasibility of dynamic susceptibility contrast perfusion MR imaging at 3T using a standard quadrature head coil and eight-channel phased-array coil with and without SENSE reconstruction [J].
Lupo, Janine M. ;
Lee, Michael C. ;
Han, Eric T. ;
Cha, Soonmee ;
Chang, Susan M. ;
Berger, Mitchel S. ;
Nelson, Sarah J. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (03) :520-529
[43]   High-Resolution Diffusion-Weighted Imaging for the Separation of Benign From Malignant BI-RADS 4/5 Lesions Found on Breast MRI at 3T [J].
Wisner, Dorota J. ;
Rogers, Nathan ;
Deshpande, Vibhas S. ;
Newitt, David N. ;
Laub, Gerhard A. ;
Porter, David A. ;
Kornak, John ;
Joe, Bonnie N. ;
Hylton, Nola M. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 40 (03) :674-681
[44]   High-Resolution Diffusion-Weighted Imaging of Neck Lymph Nodes Using 2D-Single-Shot Interleaved Multiple Inner Volume Imaging Diffusion-Weighted Echo-Planar Imaging at 3T [J].
Park, J. K. ;
Kim, S. -E. ;
Trieman, G. S. ;
Parker, D. ;
Jeong, E. -K. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (07) :1173-1177
[45]   The performance of MR perfusion-weighted imaging for the differentiation of high-grade glioma from primary central nervous system lymphoma: A systematic review and meta-analysis [J].
Xu, Weilin ;
Wang, Qun ;
Shao, Anwen ;
Xu, Bainan ;
Zhang, Jianmin .
PLOS ONE, 2017, 12 (03)
[46]   Diagnostic examination performance by using microvascular leakage, cerebral blood volume, and blood flow derived from 3-T dynamic susceptibility-weighted contrast-enhanced perfusion MR imaging in the differentiation of glioblastoma multiforme and brain metastasis [J].
Server, Andres ;
Orheim, Tone E. Doli ;
Graff, Bjorn A. ;
Josefsen, Roger ;
Kumar, Theresa ;
Nakstad, Per H. .
NEURORADIOLOGY, 2011, 53 (05) :319-330
[47]   Adding MR Diffusion Imaging and T2 Signal Intensity to Neck Imaging Reporting and Data System Categories 2 and 3 in Primary Sites of Postsurgical Oral Cavity Carcinoma Provides Incremental Diagnostic Value [J].
Jajodia, A. ;
Mandal, G. ;
Yadav, V ;
Khoda, J. ;
Goyal, J. ;
Pasricha, S. ;
Puri, S. ;
Dewan, A. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2022, :1018-1023
[48]   High-performance LT-SOFCs based on BaZr0.8Y0.2O3-δ-Na2CO3 nanocomposite electrolyte for powering IoT system [J].
Kou, Hanpeng ;
Bu, Tianlong ;
Nie, Dayu ;
Hu, Hongyuan ;
Wu, Kexin .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2024, 35 (06)
[49]   A High-Performance 3D Eight-Port THz-MIMO Antenna System Verified With Machine Learning for Enhanced Wireless Communication Systems [J].
Al-Bawri, Samir Salem ;
Abdulkawi, Wazie M. ;
Sheta, Abdel-Fattah A. ;
Moniruzzaman, Md. .
INTERNATIONAL JOURNAL OF COMMUNICATION SYSTEMS, 2025, 38 (04)
[50]   High-performance sono/nano-catalytic system: CTSN/Fe3O4-Cu nanocomposite, a promising heterogeneous catalyst for the synthesis of N-arylimidazoles [J].
Taheri-Ledari, Reza ;
Hashemi, Seyed Masoud ;
Maleki, Ali .
RSC ADVANCES, 2019, 9 (69) :40348-40356