Lightweight, compact, and high-performance 3T MR system for imaging the brain and extremities

被引:69
作者
Foo, Thomas K. F. [1 ]
Laskaris, Evangelos [1 ]
Vermilyea, Mark [1 ]
Xu, Minfeng [1 ]
Thompson, Paul [1 ]
Conte, Gene [1 ]
Van Epps, Christopher [1 ]
Immer, Christopher [1 ]
Lee, Seung-Kyun [1 ,2 ]
Tan, Ek T. [1 ]
Graziani, Dominic [1 ]
Mathieu, Jean-Baptise [3 ]
Hardy, Christopher J. [1 ]
Schenck, John F. [1 ]
Fiveland, Eric [1 ]
Stautner, Wolfgang [1 ]
Ricci, Justin [1 ]
Piel, Joseph [1 ]
Park, Keith [1 ]
Hua, Yihe [1 ]
Bai, Ye [1 ]
Kagan, Alex [1 ]
Stanley, David [5 ]
Weavers, Paul T. [4 ,5 ]
Gray, Erin [4 ]
Shu, Yunhong [4 ]
Frick, Matthew A. [4 ]
Campeau, Norbert G. [4 ]
Trzasko, Joshua [4 ]
Huston, John, III [4 ]
Bernstein, Matt A. [4 ]
机构
[1] GE Global Res, 1 Res Circle, Niskayuna, NY 12309 USA
[2] Sungkyunkwan Univ, Dept Biomed Engn, Suwon, South Korea
[3] GE Healthcare, Florence, SC USA
[4] Mayo Clin, Dept Radiol, Rochester, MN USA
[5] GE Healthcare, Waukesha, WI USA
关键词
PERIPHERAL-NERVE STIMULATION; TRANSVERSE GRADIENT COILS; CONCOMITANT FIELDS; HEAD; DISTORTION; DIFFUSION; DESIGN; LIMITS; FMRI; BODY;
D O I
10.1002/mrm.27175
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To build and evaluate a small-footprint, lightweight, high-performance 3T MRI scanner for advanced brain imaging with image quality that is equal to or better than conventional whole-body clinical 3T MRI scanners, while achieving substantial reductions in installation costs. Methods: A conduction-cooled magnet was developed that uses less than 12 liters of liquid helium in a gas-charged sealed system, and standard NbTi wire, and weighs approximately 2000 kg. A 42-cm inner-diameter gradient coil with asymmetric transverse axes was developed to provide patient access for head and extremity exams, while minimizing magnet-gradient interactions that adversely affect image quality. The gradient coil was designed to achieve simultaneous operation of 80-mT/m peak gradient amplitude at a slew rate of 700 T/m/s on each gradient axis using readily available 1-MVA gradient drivers. Results: In a comparison of anatomical imaging in 16 patients using T2-weighted 3D fluid-attenuated inversion recovery (FLAIR) between the compact 3T and whole-body 3T, image quality was assessed as equivalent to or better across several metrics. The ability to fully use a high slew rate of 700 T/m/s simultaneously with 80-mT/m maximum gradient amplitude resulted in improvements in image quality across EPI, DWI, and anatomical imaging of the brain. Conclusions: The compact 3T MRI system has been in continuous operation at the Mayo Clinic since March 2016. To date, over 200 patient studies have been completed, including 96 comparison studies with a clinical 3T whole-body MRI. The increased gradient performance has reliably resulted in consistently improved image quality.
引用
收藏
页码:2232 / 2245
页数:14
相关论文
共 50 条
[31]   Discriminating between IgG4-related orbital disease and other causes of orbital inflammation with intra voxel incoherent motion (IVIM) MR imaging at 3T [J].
Shor, Natalia ;
Sene, Thomas ;
Zuber, Kevin ;
Zmuda, Mathieu ;
Berges, Olivier ;
Savatovsky, Julien ;
Lecler, Augustin .
DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2021, 102 (12) :727-734
[32]   Evaluation of 2D multiband EPI imaging for high-resolution, whole-brain, task-based fMRI studies at 3T: Sensitivity and slice leakage artifacts [J].
Todd, Nick ;
Moeller, Steen ;
Auerbach, Edward J. ;
Yacoub, Essa ;
Flandin, Guillaume ;
Weiskopf, Nikolaus .
NEUROIMAGE, 2016, 124 :32-42
[33]   Study of kinetics of 19F-MRI using a fluorinated imaging agent (19FIT) on a 3T clinical MRI system [J].
Xin Liu ;
Zhong-Xing Jiang ;
Bruce Y. Yu ;
Eun-Kee Jeong .
Magnetic Resonance Materials in Physics, Biology and Medicine, 2019, 32 :97-103
[34]   Preoperative 3T high field blood oxygen level dependent functional magnetic resonance imaging for glioma involving sensory cortical areas [J].
Li Shao-wu ;
Wang Jiang-fei ;
Jiang Tao ;
Li Shou-wei ;
Zhang Wen-bo ;
Li Zi-xiao ;
Zhang Zhong ;
Dai Jian-ping ;
Wang Zhong-cheng .
CHINESE MEDICAL JOURNAL, 2010, 123 (08) :1006-1010
[35]   Study of kinetics of 19F-MRI using a fluorinated imaging agent (19FIT) on a 3T clinical MRI system [J].
Liu, Xin ;
Jiang, Zhong-Xing ;
Yu, Bruce Y. ;
Jeong, Eun-Kee .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2019, 32 (01) :97-103
[36]   Compact high-performance adiabatic 3-dB coupler enabled by subwavelength grating slot in the silicon-on-insulator platform [J].
Xu, Luhua ;
Wang, Yun ;
Kumar, Amar ;
El-Fiky, Eslam ;
Mao, Deng ;
Tamazin, Heba ;
Jacques, Maxime ;
Xing, Zhenping ;
Saber, Ghulam ;
Plant, David V. .
OPTICS EXPRESS, 2018, 26 (23) :29873-29885
[37]   Retrospective correction of second-order concomitant fields in 3D axial stack-of-spirals imaging on a high-performance gradient system [J].
Ajala, Afis ;
Abad, Nastaren ;
Foo, Thomas K. F. ;
Lee, Seung-Kyun .
MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (03) :1128-1137
[38]   Dynamic and High-Resolution Metabolic Imaging of Hyperpolarized [1-13C]-Pyruvate in the Rat Brain Using a High-Performance Gradient Insert [J].
Mayer, Dirk ;
Yen, Yi-Fen ;
Takahashi, Atsushi ;
Josan, Sonal ;
Tropp, James ;
Rutt, B. K. ;
Hurd, Ralph E. ;
Spielman, Daniel M. ;
Pfefferbaum, Adolf .
MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (05) :1228-1233
[39]   Development of Gd3N@C80 encapsulated redox nanoparticles for high-performance magnetic resonance imaging [J].
Gao, Zhenyu ;
Nakanishi, Yusuke ;
Noda, Shoko ;
Omachi, Haruka ;
Shinohara, Hisanori ;
Kimura, Hiroyuki ;
Nagasaki, Yukio .
JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2017, 28 (10-12) :1036-1050
[40]   A high-resolution multi-shell 3T diffusion magnetic resonance imaging dataset as part of the Amsterdam Ultra-high field adult lifespan database (AHEAD) [J].
Keuken, Max C. ;
Liebrand, Luka C. ;
Bazin, Pierre-Louis ;
Alkemade, Anneke ;
van Berendonk, Nikita ;
Groot, Josephine M. ;
Isherwood, Scott J. S. ;
Kemp, Sarah ;
Lute, Nicky ;
Mulder, Martijn J. ;
Trutti, Anne C. ;
Caan, Matthan W. A. ;
Forstmann, Birte U. .
DATA IN BRIEF, 2022, 42