Lightweight, compact, and high-performance 3T MR system for imaging the brain and extremities

被引:69
作者
Foo, Thomas K. F. [1 ]
Laskaris, Evangelos [1 ]
Vermilyea, Mark [1 ]
Xu, Minfeng [1 ]
Thompson, Paul [1 ]
Conte, Gene [1 ]
Van Epps, Christopher [1 ]
Immer, Christopher [1 ]
Lee, Seung-Kyun [1 ,2 ]
Tan, Ek T. [1 ]
Graziani, Dominic [1 ]
Mathieu, Jean-Baptise [3 ]
Hardy, Christopher J. [1 ]
Schenck, John F. [1 ]
Fiveland, Eric [1 ]
Stautner, Wolfgang [1 ]
Ricci, Justin [1 ]
Piel, Joseph [1 ]
Park, Keith [1 ]
Hua, Yihe [1 ]
Bai, Ye [1 ]
Kagan, Alex [1 ]
Stanley, David [5 ]
Weavers, Paul T. [4 ,5 ]
Gray, Erin [4 ]
Shu, Yunhong [4 ]
Frick, Matthew A. [4 ]
Campeau, Norbert G. [4 ]
Trzasko, Joshua [4 ]
Huston, John, III [4 ]
Bernstein, Matt A. [4 ]
机构
[1] GE Global Res, 1 Res Circle, Niskayuna, NY 12309 USA
[2] Sungkyunkwan Univ, Dept Biomed Engn, Suwon, South Korea
[3] GE Healthcare, Florence, SC USA
[4] Mayo Clin, Dept Radiol, Rochester, MN USA
[5] GE Healthcare, Waukesha, WI USA
关键词
PERIPHERAL-NERVE STIMULATION; TRANSVERSE GRADIENT COILS; CONCOMITANT FIELDS; HEAD; DISTORTION; DIFFUSION; DESIGN; LIMITS; FMRI; BODY;
D O I
10.1002/mrm.27175
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To build and evaluate a small-footprint, lightweight, high-performance 3T MRI scanner for advanced brain imaging with image quality that is equal to or better than conventional whole-body clinical 3T MRI scanners, while achieving substantial reductions in installation costs. Methods: A conduction-cooled magnet was developed that uses less than 12 liters of liquid helium in a gas-charged sealed system, and standard NbTi wire, and weighs approximately 2000 kg. A 42-cm inner-diameter gradient coil with asymmetric transverse axes was developed to provide patient access for head and extremity exams, while minimizing magnet-gradient interactions that adversely affect image quality. The gradient coil was designed to achieve simultaneous operation of 80-mT/m peak gradient amplitude at a slew rate of 700 T/m/s on each gradient axis using readily available 1-MVA gradient drivers. Results: In a comparison of anatomical imaging in 16 patients using T2-weighted 3D fluid-attenuated inversion recovery (FLAIR) between the compact 3T and whole-body 3T, image quality was assessed as equivalent to or better across several metrics. The ability to fully use a high slew rate of 700 T/m/s simultaneously with 80-mT/m maximum gradient amplitude resulted in improvements in image quality across EPI, DWI, and anatomical imaging of the brain. Conclusions: The compact 3T MRI system has been in continuous operation at the Mayo Clinic since March 2016. To date, over 200 patient studies have been completed, including 96 comparison studies with a clinical 3T whole-body MRI. The increased gradient performance has reliably resulted in consistently improved image quality.
引用
收藏
页码:2232 / 2245
页数:14
相关论文
共 50 条
  • [21] Nonlinear Gradient Field Mapping Using a Spherical Grid Phantom for 3 and 7 Tesla MR Imaging Systems Equipped with High-performance Gradient Coils
    Kose, Ryoichi
    Kose, Katsumi
    Fujimoto, Koji
    Okada, Tomohisa
    Tamada, Daiki
    Motosugi, Utaroh
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2024, 23 (04) : 525 - 536
  • [22] High-Performance Compact Electromagnetic Coilgun Propulsion System with Low-Voltage Modular Rapid Capacitor Charger
    Dayan, Doodi
    Evzelman, Michael
    Peretz, Mor Mordechai
    2020 THIRTY-FIFTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2020), 2020, : 1559 - 1566
  • [23] T2-weighted turbo spin-echo magnetic resonance imaging of canine brain anatomy at 1.5T, 3T, and 7T field strengths
    Jacqmot, Olivier
    Van Thielen, Bert
    Hespel, Adrien-Maxence
    Luijten, Peter R.
    de Mey, Johan
    Van Binst, Anne
    Provyn, Steven
    Tresignie, Jonathan
    ANATOMICAL RECORD-ADVANCES IN INTEGRATIVE ANATOMY AND EVOLUTIONARY BIOLOGY, 2022, 305 (01): : 222 - 233
  • [24] A High-Performance 3-D Imaging Technique Using Simultaneous Azimuth and Elevation Compounding
    Campbell, Nicholas A. A.
    MacMullin, Nicole
    Kiefl, Rachel
    Nashnoush, Eptehal
    Latham, Katherine
    Emery, Charles D. D.
    Brown, Jeremy A. A.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2022, 69 (12) : 3327 - 3337
  • [25] Single-Shot Echo-Planar Diffusion-Weighted MR Imaging at 3T and 1.5T for Differentiation of Benign Vertebral Fracture Edema and Tumor Infiltration
    Park, Hee Jin
    Lee, So Yeon
    Rho, Myung Ho
    Chung, Eun Chul
    Kim, Mi Sung
    Kwon, Heon Ju
    Youn, In Young
    KOREAN JOURNAL OF RADIOLOGY, 2016, 17 (05) : 590 - 597
  • [26] Reliability of Three-Dimensional Pseudo-Continuous Arterial Spin Labeling MR Imaging for Measuring Visual Cortex Perfusion on Two 3T Scanners
    Huang, Diandian
    Wu, Bing
    Shi, Kaining
    Ma, Lin
    Cai, Youquan
    Lou, Xin
    PLOS ONE, 2013, 8 (11):
  • [27] Prostate MR imaging at 3T using a phased-arrayed coil in predicting locally recurrent prostate cancer after radiation therapy: preliminary experience
    Kim, Chan Kyo
    Park, Byung Kwan
    Park, Won
    Kim, Sam Soo
    ABDOMINAL IMAGING, 2010, 35 (02): : 246 - 252
  • [28] An integrated head immobilization system and high-performance RF coil for fMRI of visual paradigms at 1.5 T
    Thulborn, KR
    Shen, GX
    JOURNAL OF MAGNETIC RESONANCE, 1999, 139 (01) : 26 - 34
  • [29] Investigation of a Dual-Tuned RF Coil Array Decoupled Using ICE Technique for 1H/19F MR Imaging at 3T
    Li, Nan
    Chen, Qiaoyan
    Luo, Chao
    Lee, Jo
    Du, Feng
    Zhang, Xiaoliang
    Li, Ye
    IEEE TRANSACTIONS ON MAGNETICS, 2020, 56 (01)
  • [30] Evaluation of Peritumoral Brain Parenchyma Using Contrast-Enhanced 3D Fast Imaging Employing Steady-State Acquisition at 3T for Differentiating Metastatic Brain Tumors and Glioblastomas
    Yamamoto, Junkoh
    Kakeda, Shingo
    Shimajiri, Shohei
    Nakano, Yoshiteru
    Saito, Takeshi
    Ide, Satoru
    Moriya, Junji
    Korogi, Yukunori
    Nishizawa, Shigeru
    WORLD NEUROSURGERY, 2018, 120 : E719 - E729