Spatial coefficient of variation in pseudo-continuous arterial spin labeling cerebral blood flow images as a hemodynamic measure for cerebrovascular steno-occlusive disease: A comparative 15O positron emission tomography study

被引:20
作者
Ibaraki, Masanobu [1 ]
Nakamura, Kazuhiro [1 ]
Toyoshima, Hideto [1 ]
Takahashi, Kazuhiro [1 ]
Matsubara, Keisuke [1 ]
Umetsu, Atsushi [1 ]
Pfeuffer, Josef [2 ]
Kuribayashi, Hideto [3 ]
Kinoshita, Toshibumi [1 ]
机构
[1] Akita Res Inst Brain & Blood Vessels, Dept Radiol & Nucl Med, 6-10 Senshu Kubota Machi, Akita 0100874, Japan
[2] Siemens Healthcare GmbH, Erlangen, Germany
[3] Siemens Healthcare KK, Tokyo, Japan
关键词
Arterial transit artifact; arterial transit time; cerebral blood flow; pseudo-continuous arterial spin labeling; spatial coefficient of variation; TRANSIT-TIME; PERFUSION; MRI; ACETAZOLAMIDE; METABOLISM;
D O I
10.1177/0271678X18781667
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Pseudo-continuous arterial spin labeling (pCASL) is a completely non-invasive method of cerebral perfusion measurement. However, cerebral blood flow (CBF) quantification is hampered by arterial transit artifacts characterized by bright vascular signals surrounded by decreased signals in tissue regions, which commonly appear in patients with reduced cerebral perfusion pressure. The spatial coefficient of variation (CoV) of pCASL CBF images has been proposed as an alternative region-of-interest (ROI)-based hemodynamic measure to predict prolonged arterial transit time (ATT). This retrospective study investigates the utility of spatial CoV by comparison with O-15 positron emission tomography (PET). For patients with cerebrovascular steno-occlusive disease (n = 17), spatial CoV was positively correlated with ATT independently measured by pulsed arterial spin labeling (r = 0.597, p < 0.001), confirming its role as an ATT-like hemodynamic measure. Comparisons with O-15 PET demonstrated that spatial CoV was positively correlated with vascular mean transit time (r = 0.587, p < 0.001) and negatively correlated with both resting CBF (r = -0.541, p = 0.001) and CBF response to hypercapnia (r = -0.373, p = 0.030). ROI-based spatial CoV calculated from single time-point pCASL can potentially detect subtle perfusion abnormalities in clinical settings.
引用
收藏
页码:173 / 181
页数:9
相关论文
共 42 条
  • [1] Recommended Implementation of Arterial Spin-Labeled Perfusion MRI for Clinical Applications: A Consensus of the ISMRM Perfusion Study Group and the European Consortium for ASL in Dementia
    Alsop, David C.
    Detre, John A.
    Golay, Xavier
    Guenther, Matthias
    Hendrikse, Jeroen
    Hernandez-Garcia, Luis
    Lu, Hanzhang
    MacIntosh, Bradley J.
    Parkes, Laura M.
    Smits, Marion
    van Osch, Matthias J. P.
    Wang, Danny J. J.
    Wong, Eric C.
    Zaharchuk, Greg
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (01) : 102 - 116
  • [2] 3D Pseudocontinuous arterial spin labeling in routine clinical practice: A review of clinically significant artifacts
    Amukotuwa, Shalini A.
    Yu, Caroline
    Zaharchuk, Gregory
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 43 (01) : 11 - 27
  • [3] Arterial Spin-Labeling MR Imaging Measurements of Timing Parameters in Patients with a Carotid Artery Occlusion
    Bokkers, R. P. H.
    van Laar, P. J.
    van de Ven, K. C. C.
    Kapelle, L. J.
    Klijn, C. J. M.
    Hendrikse, J.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (09) : 1698 - 1703
  • [4] A general kinetic model for quantitative perfusion imaging with arterial spin labeling
    Buxton, RB
    Frank, LR
    Wong, EC
    Siewert, B
    Warach, S
    Edelman, RR
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (03) : 383 - 396
  • [5] Separation of Macrovascular Signal in Multi-inversion Time Arterial Spin Labelling MRI
    Chappell, Michael A.
    MacIntosh, Bradley J.
    Donahue, Manus J.
    Guenther, Matthias
    Jezzard, Peter
    Woolrich, Mark W.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (05) : 1357 - 1365
  • [6] Can Arterial Spin-Labeling with Multiple Postlabeling Delays Predict Cerebrovascular Reserve?
    Choi, H. J.
    Sohn, C. -H.
    You, S. -H.
    Yoo, R. -E.
    Kang, K. M.
    Yun, T. J.
    Choi, S. H.
    Kim, J. -H.
    Cho, W. -S.
    Kim, J. E.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2018, 39 (01) : 84 - 90
  • [7] Volumetric measurement of perfusion and arterial transit delay using hadamard encoded continuous arterial spin labeling
    Dai, Weiying
    Shankaranarayanan, Ajit
    Alsop, David C.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (04) : 1014 - 1022
  • [8] Reduced resolution transit delay prescan for quantitative continuous arterial spin labeling perfusion imaging
    Dai, Weiying
    Robson, Philip M.
    Shankaranarayanan, Ajit
    Alsop, David C.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (05) : 1252 - 1265
  • [9] Applications of arterial spin labeled MRI in the brain
    Detre, John A.
    Rao, Hengyi
    Wang, Danny J. J.
    Chen, Yu Fen
    Wang, Ze
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 35 (05) : 1026 - 1037
  • [10] Comparison of PASL, PCASL, and Background-Suppressed 3D PCASL in Mild Cognitive Impairment
    Dolui, Sudipto
    Vidorreta, Marta
    Wang, Ze
    Nasrallah, Ilya M.
    Alavi, Abass
    Wolk, David A.
    Detre, John A.
    [J]. HUMAN BRAIN MAPPING, 2017, 38 (10) : 5260 - 5273