共 50 条
Cr2O72- anion fluorescent probe effective detection based on novel highly stable cadmium coordination polymers material
被引:7
|作者:
Wu Man
[1
]
Zhang Yuan
[1
]
Wang Qian
[1
]
Li Nan
[1
]
Wang Xiao
[1
]
Chai Hong-Mei
[1
]
Gao Lou-Jun
[1
]
Hou Xiang-Yang
[1
]
机构:
[1] Yanan Univ, Dept Chem & Chem Engn, Shaanxi Key Lab Chem React Engn, Lab New Energy & New Funct Mat, Yanan 716000, Shaanxi, Peoples R China
关键词:
Cd-CPs;
Synthesis;
Characterization;
Fluorescent probe;
Cr2O72-;
SELECTIVE DETECTION;
WATER;
IONS;
ADSORPTION;
CAPTURE;
MOFS;
D O I:
10.1016/j.jssc.2022.122883
中图分类号:
O61 [无机化学];
学科分类号:
070301 ;
081704 ;
摘要:
Coordination polymers (CPs) have been used in fluorescent probes because of their brilliant fluorescence features and Unique structural. As a result, a few Cd-CPs were applied in detecting metal ions, inorganic anions, and small molecules. In this work, four novel and effective fluorescent probe CPs materials using 4,4-bis-(imidazolyl)-biphenyl (BIB), small moleculeorganic acid ligands (Pimelicacid (H2PCA), Suberic acid (H2SCA), Diglycolic acid (DCA), Iminodiacetic acid (ICA)) and Cd2} by solvothermal method were designed and prepared, namely [Cd(BIB) (SCA)]n (1), [Cd2(BIB)2(PCA)2]n (2), [Cd(BIB) (ICA) (H2O)]n (3), [Cd(BIB) (DCA) (H2O)]n.n (H2O) (4), showing excellent fluorescence performance in detecting Cr2O72- in aqueous solution. Analysis of single crystal structure determination results, CP-1 and 2 presents adouble layer 2D structure with different coordination en-vironments for center Cd2}. CP-3 and 4 possess 3D supramolecular structure, and which stability is enhanced by multiple and strong pi...pi stacking interactions. In each of the four probes, the voilet-emission signal is attributed to the charge transfer within the BIB ligand in CPs 1-4, which can selectively detect Cr2O72- anions in the solution with excellent selectivity and sensitivity. The individual high quenching percentage (CP-1:98.86%, CP-2:99.38%, CP-3:99.19%, CP-4: 99.15%), quenching efficiency Ksv (CP-1:1.41 x 105, CP-2:1.31 x 105, CP-3:1.16 x 105, CP-4: 1.11 x 105) and detection limits (CP-1: 1.37 x 10-6, CP-2: 7.33 x 10-7, CP-3: 1.48 x 10-7, CP-4: 3.29 x 10-7) were regarded as the excellent CPs sensors for detecting Cr2O72- anions. The relevant parameters are approximate to the permissible limits allowed by the USEPA. The mechanism for Cr2O72- quenching involves overlap of the excitation or emission bands of CPs 1-4 with absorption bands of recognition anions. As far as we know, this is a good example of using fluorescence properties to detect Cr2O72-. This method possesses potential application for the determination of Cr2O72- in various sewage solutions.
引用
收藏
页数:9
相关论文