Data filtering in the readout of the CMS Electromagnetic Calorimeter

被引:0
作者
Almeida, N. [1 ]
Silva, P. [1 ]
Da Silva, J. C. [1 ]
Husejko, M. [1 ]
Jain, A. [1 ]
Musella, P. [1 ]
Mendes, A. [1 ]
Gallinaro, M. [1 ]
Varela, J. [1 ]
Faure, J. -L. [2 ]
Gras, P. [2 ]
Mandjavidze, L. [2 ]
Busson, P. [3 ]
Paganini, P. [3 ]
机构
[1] LIP, Lisbon, Portugal
[2] CEA Saclay, DAPNIA, Saclay, France
[3] Ecole Polytech, CNRS, IN2P3, LLR, F-91128 Palaiseau, France
来源
2007 15TH IEEE-NPSS REAL-TIME CONFERENCE, VOLS 1 AND 2 | 2007年
关键词
data acquisition; data filtering; CMS; LHC; trigger system; selective readout; trigger systems;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
For an efficient data talking, the Electromagnetic Calorimeter (ECAL) data of the CMS experiment must be limited to 10% of the full event size (INS). Other requirements limit the average data size to 2kB per data acquisition link. These conditions imply a reduction factor of close to twenty on the data collected. The data filtering in the readout of the ECAL detector is discussed. Test beam data are used to study the digital filtering applied in the readout channels and a full detector simulation allows to estimate the energy thresholds to achieve the desired data suppression factor.
引用
收藏
页码:571 / +
页数:2
相关论文
共 15 条
[1]   Overview of the ECAL off-detector electronics of the CMS experiment [J].
Alemany, R ;
Almeida, CB ;
Almeida, N ;
Bercher, M ;
Benetta, R ;
Bexiga, V ;
Bourotte, J ;
Busson, P ;
Cardoso, N ;
Cerrutti, M ;
Dejardin, M ;
Faure, JL ;
Gachelin, O ;
Gastal, M ;
Geerebaert, Y ;
Gilly, J ;
Gras, P ;
Hansen, M ;
Husejko, M ;
Jain, A ;
Karar, A ;
Kloukinas, K ;
Ljuslin, C ;
Machado, P ;
Mandjavidze, I ;
Mur, M ;
Paganini, P ;
Regnault, N ;
Santos, M ;
Da Silva, JC ;
Teixeira, I ;
Teixeira, JP ;
Varela, J ;
Verrecchia, P ;
Zlatevski, L .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (05) :1918-1924
[2]   The selective read-out processor for the CMS electromagnetic calorimeter [J].
Almeida, N ;
Busson, P ;
Faure, JL ;
Gachelin, O ;
Gras, P ;
Mandjavidze, I ;
Mur, M ;
Varela, J .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (03) :772-777
[3]   Calorimeter trigger synchronization in the CMS experiment [J].
Almeida, N. ;
Da Silva, J. C. ;
Alemany, R. ;
Almeida, C. ;
Santos, M. ;
Teixeira, I. ;
Teixeira, J. P. ;
Varela, J. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 568 (02) :634-641
[4]  
ALMEIDA N, 2003056 CMS ECAL
[5]  
ALMEIDA N, 2005, 2005021 CMS
[6]  
ALMEIDA N, TS2006002 CMS
[7]  
BENETTA R, 1997059 CMS
[8]  
*CMS COLL, 9438 CERN LHCC
[9]  
*CMS COLL, 2000038 CERN LHCC
[10]  
*CMS COLL, 9733 CERN LHCC