Engineering an integrated system with a high pressure polymeric microfluidic chip coupled to liquid chromatography-mass spectrometry (LC-MS) for the analysis of abused drugs

被引:15
|
作者
Chen, Pin-Chuan [1 ,2 ]
Zhang, Wei-Zhe [1 ]
Chen, Wei-Ru [3 ]
Jair, Yung-Cheng [3 ]
Wu, Yi-Hsin [3 ]
Liu, Yi-Hsin [4 ]
Chen, Pei-Zhen [1 ]
Chen, Lian-Yu [5 ,6 ]
Chen, Pai-Shan [3 ]
机构
[1] Natl Taiwan Univ Scinece & Technol, Dept Mech Engn, Taipei, Taiwan
[2] Natl Taiwan Univ Scinece & Technol, High Speed 3D Printing Res Ctr, Taipei, Taiwan
[3] Natl Taiwan Univ, Inst Toxicol, Coll Med, Taipei, Taiwan
[4] Natl Taiwan Normal Univ, Dept Chem, Taipei, Taiwan
[5] Taipei City Hosp, Kunming Prevent & Control Ctr, Taipei, Taiwan
[6] Natl Taiwan Univ, Inst Epidemiol & Prevent Med, Taipei, Taiwan
关键词
Integrating microfluidics chip; Chromatography; LC-MS; Addictive polymeric; One-piece; Drugs of abuse; ON-A-CHIP; CONDUCTIVITY DETECTION; LAB; METABOLITES; SEPARATION; HPLC;
D O I
10.1016/j.snb.2021.130888
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A microfluidic chip coupled to a liquid chromatography-mass spectrometry (LC-MS) system is a powerful tool to determine components of interest in tracing biological samples. However, producing a reusable and robust chip having chromatographic separation for LC-MS systems remains analytically challenging due to the high back pressure generally occurring when microfluidic channels are packed particles. In this study, a one-piece and high-pressure-resistant polymeric microfluidic chip was fabricated by commercial stereolithographic 3D printing with an inner diameter of 1 mm, packed with 5 mu m diameter fluorophenyl propyl particles, and coupled to a regular LC-MS. The maximum pressure occurred up to 134 bar with a variation of 1 bar when using 70% methanol at a flow rate of 0.035 mL min(-1). Ten drugs and two drug metabolites were analyzed in 15 min under continuous pressure change by LC-MS. The limit of detection was between 2 and 20 ng mL(-1) in human urine. The coefficient of determination (R-2) was > 0.991. The shift of retention time of each peak was maintained at < 2%. After a chip was eluted with a high organic solvent composition (90% methanol/water and 90% acetonitrile/water mixture) and a high back pressure for continuously 45 h, the cross-sectional areas were investigated and results showed that the microfluidic chip remained intact. The overall experiment results showed that this platform had significant reproducibility, robustness and stability without contamination, demonstrating that this 3D printing microfluidic chip coupled with LC-MS is an efficient and precise tool for bioanalysis.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] A fast liquid chromatography-mass spectrometry (LC-MS) method for quantification of major polar metabolites in plants
    Liu, Zhiqian
    Rochfort, Simone
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 912 : 8 - 15
  • [42] Liquid chromatography-mass spectrometry (LC-MS):: a powerful combination for selenium speciation in garlic (Allium sativum)
    Dumont, E
    Ogra, Y
    Vanhaecke, F
    Suzuki, KT
    Cornelis, R
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 384 (05) : 1196 - 1206
  • [43] Rapid quantification of juvenile hormones and their metabolites in insect haemolymph by liquid chromatography-mass spectrometry (LC-MS)
    Westerlund, SA
    Hoffmann, KH
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 379 (03) : 540 - 543
  • [44] Analysis of mammalian sphingolipids by liquid chromatography tandem mass spectrometry (LC-MS/MS) and tissue imaging mass spectrometry (TIMS)
    Sullards, M. Cameron
    Liu, Ying
    Chen, Yanfeng
    Merrill, Alfred H., Jr.
    BIOCHIMICA ET BIOPHYSICA ACTA-MOLECULAR AND CELL BIOLOGY OF LIPIDS, 2011, 1811 (11): : 838 - 853
  • [45] Semi-automated liquid chromatography-mass spectrometry (LC-MS/MS) method for basic pesticides in wastewater effluents
    Cahill, Michael G.
    Caprioli, Giovanni
    Stack, Mary
    Vittori, Sauro
    James, Kevin J.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (02) : 587 - 594
  • [46] Determination of mass concentrations of airborne PET microplastics using liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS)
    Patnana, Durga Prasad
    Chandra, B. P.
    ENVIRONMENTAL SCIENCE-ATMOSPHERES, 2024, 4 (12):
  • [47] The determination of sulfonamides in honey by high performance liquid chromatography-mass spectrometry method (LC/MS)
    Krivohlavek, A
    Smit, Z
    Bastinac, M
    Zuntar, I
    Plavsic-Plavsic, F
    JOURNAL OF SEPARATION SCIENCE, 2005, 28 (13) : 1434 - 1439
  • [48] Determination of hydrophilic marine biotoxins in bivalve molluscs by liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS)
    Besbes, Nadia
    Monser, Lotfi
    Nabli, Brahim Aoun
    Sadok, Saloua
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2024, 130
  • [49] PRINCIPAL COMPONENT ANALYSIS (PCA) EVALUATION OF LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LC-MS) DATASETS OF Ganoderma boninense INTRACELLULAR METABOLITES
    Nurazah, Zain
    Othman, Abrizah
    Ramli, Umi Salamah
    JOURNAL OF OIL PALM RESEARCH, 2021, 33 (03): : 555 - 564
  • [50] Valproic acid determination by liquid chromatography coupled to mass spectrometry (LC-MS/MS) in whole blood for forensic purposes
    Pascali, Jennifer P.
    Giorgetti, Arianna
    Barone, Rossella
    Pelletti, Guido
    Fais, Paolo
    DRUG TESTING AND ANALYSIS, 2023, 15 (01) : 128 - 133