Engineering an integrated system with a high pressure polymeric microfluidic chip coupled to liquid chromatography-mass spectrometry (LC-MS) for the analysis of abused drugs

被引:15
|
作者
Chen, Pin-Chuan [1 ,2 ]
Zhang, Wei-Zhe [1 ]
Chen, Wei-Ru [3 ]
Jair, Yung-Cheng [3 ]
Wu, Yi-Hsin [3 ]
Liu, Yi-Hsin [4 ]
Chen, Pei-Zhen [1 ]
Chen, Lian-Yu [5 ,6 ]
Chen, Pai-Shan [3 ]
机构
[1] Natl Taiwan Univ Scinece & Technol, Dept Mech Engn, Taipei, Taiwan
[2] Natl Taiwan Univ Scinece & Technol, High Speed 3D Printing Res Ctr, Taipei, Taiwan
[3] Natl Taiwan Univ, Inst Toxicol, Coll Med, Taipei, Taiwan
[4] Natl Taiwan Normal Univ, Dept Chem, Taipei, Taiwan
[5] Taipei City Hosp, Kunming Prevent & Control Ctr, Taipei, Taiwan
[6] Natl Taiwan Univ, Inst Epidemiol & Prevent Med, Taipei, Taiwan
关键词
Integrating microfluidics chip; Chromatography; LC-MS; Addictive polymeric; One-piece; Drugs of abuse; ON-A-CHIP; CONDUCTIVITY DETECTION; LAB; METABOLITES; SEPARATION; HPLC;
D O I
10.1016/j.snb.2021.130888
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A microfluidic chip coupled to a liquid chromatography-mass spectrometry (LC-MS) system is a powerful tool to determine components of interest in tracing biological samples. However, producing a reusable and robust chip having chromatographic separation for LC-MS systems remains analytically challenging due to the high back pressure generally occurring when microfluidic channels are packed particles. In this study, a one-piece and high-pressure-resistant polymeric microfluidic chip was fabricated by commercial stereolithographic 3D printing with an inner diameter of 1 mm, packed with 5 mu m diameter fluorophenyl propyl particles, and coupled to a regular LC-MS. The maximum pressure occurred up to 134 bar with a variation of 1 bar when using 70% methanol at a flow rate of 0.035 mL min(-1). Ten drugs and two drug metabolites were analyzed in 15 min under continuous pressure change by LC-MS. The limit of detection was between 2 and 20 ng mL(-1) in human urine. The coefficient of determination (R-2) was > 0.991. The shift of retention time of each peak was maintained at < 2%. After a chip was eluted with a high organic solvent composition (90% methanol/water and 90% acetonitrile/water mixture) and a high back pressure for continuously 45 h, the cross-sectional areas were investigated and results showed that the microfluidic chip remained intact. The overall experiment results showed that this platform had significant reproducibility, robustness and stability without contamination, demonstrating that this 3D printing microfluidic chip coupled with LC-MS is an efficient and precise tool for bioanalysis.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Proteomic analysis of Taenia hydatigena metacestode by high performance liquid chromatography-coupled tandem mass spectrometry (LC-MS/MS)
    Hai Taoxiang
    Bao-Chenghao
    Xing, Xiao-Yong
    Feng-Qinwen
    INDIAN JOURNAL OF ANIMAL SCIENCES, 2018, 88 (08): : 881 - 886
  • [22] Utility of high resolution Liquid Chromatography-Mass Spectrometry (LC-MS) for assessment of individual differences in intestinal permeability
    Henderson, W.
    Diallo, A.
    Fourie, N.
    Walter, E.
    Boulineaux, C.
    Sherwin, L.
    Joseph, P.
    Weaver, K.
    Harrell, F.
    Zhang, X.
    Walter, P.
    NEUROGASTROENTEROLOGY AND MOTILITY, 2018, 30
  • [23] Assessment of an ibuprofen metabolism by zebrafish larvae, using liquid chromatography-mass spectrometry (LC-MS)
    Jones, Huw S.
    Trollope, Henry T.
    Hutchinson, Thomas H.
    Panter, Grace H.
    Chipman, J. Kevin
    TOXICOLOGY, 2009, 262 (01) : 14 - 15
  • [24] Pharmacokinetics and Bioequivalence of Methotrexate in Human Plasma Studied by Liquid Chromatography-Mass Spectrometry (LC-MS)
    Danafar, Hossein
    Hamidi, Mehrdad
    JUNDISHAPUR JOURNAL OF NATURAL PHARMACEUTICAL PRODUCTS, 2016, 11 (02)
  • [25] Simultaneous quantification of sirolimus, everolimus, tacrolimus and cyclosporine by liquid chromatography-mass spectrometry (LC-MS)
    Deters, M
    Kirchner, G
    Resch, K
    Kaever, V
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2002, 40 (03) : 285 - 292
  • [26] Analysis of verteporfin liposomal formulations for phospholipids and phospholipid degradation products by liquid chromatography-mass spectrometry (LC-MS)
    Ansar, Siyam M.
    Jiang, Wenlei
    Mudalige, Thilak
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2022, 208
  • [27] Development and validation of a liquid chromatography-mass spectrometry (LC-MS/MS) method for amikacin and polymyxin B monitoring
    Derogis, P. B. M. C.
    Batista, M. C.
    Sanches, L. R.
    Faulhaber, A. C. L.
    Mangueira, C. L. P.
    Ferreira, C. E. S.
    CLINICA CHIMICA ACTA, 2019, 493 : S696 - S696
  • [28] Liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) methods for the therapeutic drug monitoring of cytotoxic anticancer drugs: An update
    Briki, M.
    Murisier, A.
    Guidi, M.
    Seydoux, C.
    Buclin, T.
    Marzolini, C.
    Girardin, F. R.
    Thoma, Y.
    Carrara, S.
    Choong, E.
    Decosterd, L. A.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2024, 1236
  • [29] Chiral liquid chromatography-mass spectrometry (LC-MS/MS) method development for the detection of salbutamol in urine samples
    Hay, Chan Sue
    Lee, Warren
    Asmawi, Mohd. Zaini
    Choon, Tan Soo
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1025 : 83 - 91
  • [30] Analysis of Chlormequat residues in grain using liquid chromatography mass spectrometry (LC-MS/MS)
    Vahl, M
    Graven, A
    Juhler, RK
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 361 (08): : 817 - 820