Engineering an integrated system with a high pressure polymeric microfluidic chip coupled to liquid chromatography-mass spectrometry (LC-MS) for the analysis of abused drugs

被引:15
作者
Chen, Pin-Chuan [1 ,2 ]
Zhang, Wei-Zhe [1 ]
Chen, Wei-Ru [3 ]
Jair, Yung-Cheng [3 ]
Wu, Yi-Hsin [3 ]
Liu, Yi-Hsin [4 ]
Chen, Pei-Zhen [1 ]
Chen, Lian-Yu [5 ,6 ]
Chen, Pai-Shan [3 ]
机构
[1] Natl Taiwan Univ Scinece & Technol, Dept Mech Engn, Taipei, Taiwan
[2] Natl Taiwan Univ Scinece & Technol, High Speed 3D Printing Res Ctr, Taipei, Taiwan
[3] Natl Taiwan Univ, Inst Toxicol, Coll Med, Taipei, Taiwan
[4] Natl Taiwan Normal Univ, Dept Chem, Taipei, Taiwan
[5] Taipei City Hosp, Kunming Prevent & Control Ctr, Taipei, Taiwan
[6] Natl Taiwan Univ, Inst Epidemiol & Prevent Med, Taipei, Taiwan
关键词
Integrating microfluidics chip; Chromatography; LC-MS; Addictive polymeric; One-piece; Drugs of abuse; ON-A-CHIP; CONDUCTIVITY DETECTION; LAB; METABOLITES; SEPARATION; HPLC;
D O I
10.1016/j.snb.2021.130888
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A microfluidic chip coupled to a liquid chromatography-mass spectrometry (LC-MS) system is a powerful tool to determine components of interest in tracing biological samples. However, producing a reusable and robust chip having chromatographic separation for LC-MS systems remains analytically challenging due to the high back pressure generally occurring when microfluidic channels are packed particles. In this study, a one-piece and high-pressure-resistant polymeric microfluidic chip was fabricated by commercial stereolithographic 3D printing with an inner diameter of 1 mm, packed with 5 mu m diameter fluorophenyl propyl particles, and coupled to a regular LC-MS. The maximum pressure occurred up to 134 bar with a variation of 1 bar when using 70% methanol at a flow rate of 0.035 mL min(-1). Ten drugs and two drug metabolites were analyzed in 15 min under continuous pressure change by LC-MS. The limit of detection was between 2 and 20 ng mL(-1) in human urine. The coefficient of determination (R-2) was > 0.991. The shift of retention time of each peak was maintained at < 2%. After a chip was eluted with a high organic solvent composition (90% methanol/water and 90% acetonitrile/water mixture) and a high back pressure for continuously 45 h, the cross-sectional areas were investigated and results showed that the microfluidic chip remained intact. The overall experiment results showed that this platform had significant reproducibility, robustness and stability without contamination, demonstrating that this 3D printing microfluidic chip coupled with LC-MS is an efficient and precise tool for bioanalysis.
引用
收藏
页数:10
相关论文
共 45 条
  • [1] [Anonymous], 2006, SOFT/AAFS Forensic Laboratory Guidelines
  • [2] Detection principles and development of microfluidic sensors in the last decade
    Antony, Rahul
    Nandagopal, M. S. Giri
    Sreekumar, Nidhin
    Selvaraju, N.
    [J]. MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2014, 20 (06): : 1051 - 1061
  • [3] 3D-Printed Microfluidics
    Au, Anthony K.
    Huynh, Wilson
    Horowitz, Lisa F.
    Folch, Albert
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2016, 55 (12) : 3862 - 3881
  • [4] Robust, reproducible and quantitative analysis of thousands of proteomes by micro-flow LC-MS/MS
    Bian, Yangyang
    Zheng, Runsheng
    Bayer, Florian P.
    Wong, Cassandra
    Chang, Yun-Chien
    Meng, Chen
    Zolg, Daniel P.
    Reinecke, Maria
    Zecha, Jana
    Wiechmann, Svenja
    Heinzlmeir, Stephanie
    Scherr, Johannes
    Hemmer, Bernhard
    Baynham, Mike
    Gingras, Anne-Claude
    Boychenko, Oleksandr
    Kuster, Bernhard
    [J]. NATURE COMMUNICATIONS, 2020, 11 (01)
  • [5] Recent Developments in Paper-Based Microfluidic Devices
    Cate, David M.
    Adkins, Jaclyn A.
    Mettakoonpitak, Jaruwan
    Henry, Charles S.
    [J]. ANALYTICAL CHEMISTRY, 2015, 87 (01) : 19 - 41
  • [6] Monolithic Integration of Two-Dimensional Liquid Chromatography-Capillary Electrophoresis and Electrospray Ionization on a Microfluidic Device
    Chambers, Andrew G.
    Mellors, J. Scott
    Henley, W. Hampton
    Ramsey, J. Michael
    [J]. ANALYTICAL CHEMISTRY, 2011, 83 (03) : 842 - 849
  • [7] Simple, Cost-Effective 3D Printed Microfluidic Components for Disposable, Point-of-Care Colorimetric Analysis
    Chan, Ho Nam
    Shu, Yiwei
    Xiong, Bin
    Chen, Yangfan
    Chen, Yin
    Tian, Qian
    Michael, Sean A.
    Shen, Bo
    Wu, Hongkai
    [J]. ACS SENSORS, 2016, 1 (03): : 227 - 234
  • [8] Optimization of micromilling microchannels on a polycarbonate substrate
    Chen, Pin-Chuan
    Pan, Chang-Wei
    Lee, Wei-Chen
    Li, Kuan-Ming
    [J]. INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2014, 15 (01) : 149 - 154
  • [9] A Rapid and Low Cost Manufacturing for Polymeric Microfluidic Devices
    Chen, Pin-Chuan
    Wang, Zhiping
    [J]. ADVANCED MANUFACTURING FOCUSING ON MULTI-DISCIPLINARY TECHNOLOGIES, 2012, 579 : 348 - 356
  • [10] Microfluidics and Raman microscopy: current applications and future challenges
    Chrimes, Adam F.
    Khoshmanesh, Khashayar
    Stoddart, Paul R.
    Mitchell, Arnan
    Kalantar-zadeh, Kourosh
    [J]. CHEMICAL SOCIETY REVIEWS, 2013, 42 (13) : 5880 - 5906