Three-Dimensional Coronary Artery Microscopy by Intracoronary Optical Frequency Domain Imaging

被引:239
|
作者
Tearney, Guillermo J. [1 ,3 ,5 ]
Waxman, Sergio [4 ,6 ]
Shishkov, Milen [2 ]
Vakoc, Benjamin J. [2 ]
Suter, Melissa J. [2 ]
Freilich, Mark I. [4 ]
Desjardins, Adrien E. [2 ,5 ]
Oh, Wang-Yul [2 ]
Bartlett, Lisa A. [2 ]
Rosenberg, Mireille
Bouma, Brett E. [2 ,5 ]
机构
[1] Harvard Univ, Sch Med, Massachusetts Gen Hosp, Wellman Ctr Photomed, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Dept Dermatol, Boston, MA 02114 USA
[3] Harvard Univ, Sch Med, Dept Pathol, Boston, MA 02114 USA
[4] Lahey Clin Fdn, Dept Cardiol, Burlington, MA USA
[5] MIT, Harvard Mit Div Hlth Sci & Technol, Cambridge, MA 02139 USA
[6] Tufts Univ, Sch Med, Boston, MA 02111 USA
关键词
intravascular imaging; coronary imaging; optical coherence tomography; stents;
D O I
10.1016/j.jcmg.2008.06.007
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES We present the first clinical experience with intracoronary optical frequency domain imaging (OFDI) in human patients. BACKGROUND Intracoronary optical coherence tomography (OCT) is a catheter-based optical imaging modality that is capable of providing microscopic (similar to 7-mu m axial resolution, similar to 30-mu m transverse resolution), cross-sectional images of the coronary wall. Although the use of OCT has shown substantial promise for imaging coronary microstructure, blood attenuates the OCT signal, necessitating prolonged, proximal occlusion to screen long arterial segments. OFDI is a second-generation form of OCT that is capable of acquiring images at much higher frame rates. The increased speed of OFDI enables rapid, 3-dimensional imaging of long coronary segments after a brief, nonocclusive saline purge. METHODS Volumetric OFDI images were obtained in 3 patients after intracoronary stent deployment. Imaging was performed in the left anterior descending and right coronary arteries with the use of a nonocclusive saline purge rates ranging from 3 to 4 ml/s and for purge durations of 3 to 4 s. After imaging, the OFDI datasets were segmented using previously documented criteria and volume rendered. RESULTS Good visualization of the artery wall was obtained in all cases, with clear viewing lengths ranging from 3.0 to 7.0 cm at pullback rates ranging from 5 to 20 mm/s. A diverse range of microscopic features were identified in 2 and 3 dimensions, including thin-capped fibroatheromas, calcium, macrophages, cholesterol crystals, bare stent struts, and stents with neointimal hyperplasia. There were no complications of the OFDI procedure. CONCLUSIONS Our results demonstrate that OFDI is a viable method for imaging the microstructure of long coronary segments in patients. Given its ability to provide microscopic information in a practical manner, this technology may be useful for studying human coronary pathophysiology in vivo and as a clinical tool for guiding the management of coronary artery disease. (J Am Coll Cardiol Img 2008; 1:752-61) (C) 2008 by the American College of Cardiology Foundation
引用
收藏
页码:752 / 761
页数:10
相关论文
共 50 条
  • [31] In vivo three-dimensional imaging of human corneal nerves using Fourier- domain optical coherence tomography
    Shin, Jun Geun
    Hwang, Ho Sik
    Eom, Tae Joong
    Lee, Byeong Ha
    JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (01)
  • [32] Three-dimensional live imaging of bovine embryos by optical coherence tomography
    Masuda, Yasumitsu
    Hasebe, Ryo
    Kuromi, Yasushi
    Kobayashi, Masayoshi
    Iwamoto, Misaki
    Hishinuma, Mitsugu
    Ohbayashi, Tetsuya
    Nishimura, Ryo
    JOURNAL OF REPRODUCTION AND DEVELOPMENT, 2021, 67 (02) : 149 - 154
  • [33] Optical Coherence Tomography for Three-Dimensional Imaging in the Biomedical Field: A Review
    Zheng, Shu
    Bai, Yanru
    Xu, Zihao
    Liu, Pengfei
    Ni, Guangjian
    FRONTIERS IN PHYSICS, 2021, 9
  • [34] Anatomically correct three-dimensional coronary artery reconstruction using frequency domain optical coherence tomographic and angiographic data: head-to-head comparison with intravascular ultrasound for endothelial shear stress assessment in humans
    Papafaklis, Michail I.
    Bourantas, Christos V.
    Yonetsu, Taishi
    Vergallo, Rocco
    Kotsia, Anna
    Nakatani, Shimpei
    Lakkas, Lampros S.
    Athanasiou, Lambros S.
    Naka, Katerina K.
    Fotiadis, Dimitrios I.
    Feldman, Charles L.
    Stone, Peter H.
    Serruys, Patrick W.
    Jang, Ik-Kyung
    Michalis, Lampros K.
    EUROINTERVENTION, 2015, 11 (04) : 407 - 415
  • [35] The invasive intracoronary imaging assessment of left main coronary artery disease
    Dregoesc, Mihaela Ioana
    Iancu, Adrian Corneliu
    Homorodean, Calin
    MEDICAL ULTRASONOGRAPHY, 2022, 24 (02) : 219 - 225
  • [36] Extension of spectral domain phase Microscopy to three-dimensional nanoscale displacement mapping in cardiomyocytes
    Ellerbee, Audrey K.
    Hendargo, Hansford C.
    Motomura, Amy R.
    Izatt, Joseph A.
    THREE-DIMENSIONAL AND MULTIDIMENSIONAL MICROSCOPY: IMAGE ACQUISITION AND PROCESSING XV, 2008, 6861
  • [37] Optimized Computer-Aided Segmentation and Three-Dimensional Reconstruction Using Intracoronary Optical Coherence Tomography
    Athanasiou, Lambros
    Nezami, Farhad Rikhtegar
    Galon, Micheli Zanotti
    Lopes, Augusto Celso
    Lemos, Pedro Alves
    de la Torre Hernandez, Jose M.
    Ben-Assa, Eyal
    Edelman, Elazer R.
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2018, 22 (04) : 1168 - 1176
  • [38] Imaging assessment and accuracy in coronary artery autopsy: comparison of frequency-domain optical coherence tomography with intravascular ultrasound and histology
    Aiko Shimokado
    Takashi Kubo
    Yoshiki Matsuo
    Yasushi Ino
    Yasutsugu Shiono
    Kunihiro Shimamura
    Yosuke Katayama
    Akira Taruya
    Tsuyoshi Nishiguchi
    Manabu Kashiwagi
    Hironori Kitabata
    Atsushi Tanaka
    Takeshi Hozumi
    Takashi Akasaka
    The International Journal of Cardiovascular Imaging, 2019, 35 : 1785 - 1790
  • [39] Imaging assessment and accuracy in coronary artery autopsy: comparison of frequency-domain optical coherence tomography with intravascular ultrasound and histology
    Shimokado, Aiko
    Kubo, Takashi
    Matsu, Yoshiki
    Ino, Yasushi
    Shiono, Yasutsugu
    Shimamura, Kunihiro
    Katayama, Yosuke
    Taruya, Akira
    Nishiguchi, Tsuyoshi
    Kashiwagi, Manabu
    Kitabata, Hironori
    Tanaka, Atsushi
    Hozumi, Takeshi
    Akasaka, Takashi
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2019, 35 (10) : 1785 - 1790
  • [40] First-in-man evaluation of intravascular optical frequency domain imaging (OFDI) of Terumo: a comparison with intravascular ultrasound and quantitative coronary angiography
    Okamura, Takayuki
    Onuma, Yoshinobu
    Garcia-Garcia, Hector M.
    van Geuns, Robert-Jan M.
    Wykrzykowska, Joanna J.
    Schultz, Carl
    van der Giessen, Willem J.
    Ligthart, Jurgen
    Regar, Evelyn
    Serruys, Patrick W.
    EUROINTERVENTION, 2011, 6 (09) : 1037 - 1045