154 GHz collective Thomson scattering in LHD

被引:2
|
作者
Tanaka, K. [1 ,2 ]
Nishiura, M. [3 ]
Kubo, S. [1 ,4 ]
Shimozuma, T. [1 ]
Saito, T. [5 ]
Moseev, D. [6 ]
Abramovic, I. [6 ]
机构
[1] Natl Inst Fus Sci, High Temp Plasma Phys Res Div, 322-6 Oroshi Cho, Toki, Gifu 5095292, Japan
[2] Kyushu Univ, Interdisciplinary Grad Sch Engn Sci, Dept Adv Energy Engn, Kasuga, Fukuoka 8168580, Japan
[3] Nagoya Univ, Dept Energy Engn & Sci, Nagoya, Aichi 4648603, Japan
[4] Univ Tokyo, Grad Sch Frontier Sci, Kashiwa, Chiba 2778561, Japan
[5] Univ Fukui, Res Ctr Dev Far Infrared Reg, Fukui 9108507, Japan
[6] Max Planck Inst Plasma Phys, Wendelsteinstr, D-17491 Greifswald, Germany
来源
关键词
Plasma diagnostics - interferometry; spectroscopy and imaging; Waveguides;
D O I
10.1088/1748-0221/13/01/C01010
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Collective Thomson scattering (CTS) was developed by using a 154 GHz gyrotron, and the first data has been obtained. Already, 77 GHz CTS has worked successfully. However, in order to access higher density region, 154 GHz option enhances the usability that reduces the refraction effect, which deteriorates in the local measurements. The system in the down converted frequency was almost identical to the system for 77 GHz. Probing beam, a notch filter, a mixer, and a local oscillator in the receiver system for 77 GHz option were replaced to those for the 154 GHz option. 154 GHz gyrotron was originally prepared for the second harmonic electron cyclotron heating (ECRH) at 2.75 T. However, scattering signal was masked by the second harmonic electron cyclotron emission (ECE) at 2.75 T. Therefore, 154 GHz CTS was operated at 1.375 T with fourth harmonic ECE, and an acceptable signal to noise ratio was obtained. There is a signature of fast ion components with neutral beam (NB) injection. In addition, the CTS spectrum became broader in hydrogen discharge than in deuterium discharge, as the theoretical CTS spectrum expects. This observation indicates a possibility to identify ion species ratio by the 154 GHz CTS diagnostic.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Collective Thomson scattering with 77, 154, and 300 GHz sources in LHD
    Nishiura, M.
    Tanaka, K.
    Kubo, S.
    Saito, T.
    Kenmochi, N.
    Nuga, H.
    Seki, R.
    Shimozuma, T.
    Yoshimura, Y.
    Igami, H.
    Takahashi, H.
    Tsujimura, T. I.
    Yanai, R.
    Tatematsu, Y.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (01):
  • [2] Progress of microwave collective Thomson scattering in LHD
    Tanaka, K.
    Nishiura, M.
    Kubo, S.
    Shimozuma, T.
    Saito, T.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [3] Collective Thomson Scattering of 77 GHz High-Power ECRH Beam in LHD
    Kubo, S.
    Nishiura, M.
    Tanaka, K.
    Tamura, N.
    Shimozuma, T.
    Tatematsu, Y.
    Saito, T.
    Yoshimura, Y.
    Igami, H.
    Takahashi, H.
    Ikeda, R.
    CONTRIBUTIONS TO PLASMA PHYSICS, 2010, 50 (6-7) : 624 - 628
  • [4] Feasibility Study of Collective Thomson Scattering in LHD Plasma Using a 400 GHz Frequency Gyrotron
    Tatematsu, Yoshinori
    Saito, Teruo
    Notake, Takashi
    Kubo, Shin
    Shimozuma, Takashi
    Tanaka, Kenji
    Nishiura, Masaki
    2008 33RD INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER AND TERAHERTZ WAVES, VOLS 1 AND 2, 2008, : 492 - +
  • [5] Subterahertz gyrotron developments for collective Thomson scattering in LHD
    Notake, T.
    Saito, T.
    Tatematsu, Y.
    Kubo, S.
    Shimozuma, T.
    Tanaka, K.
    Nishiura, M.
    Fujii, A.
    Agusu, La
    Ogawa, I.
    Idehara, T.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (10):
  • [6] High Power Oscillation Experiment of a Prototype Gyrotron for 300 GHz Band Collective Thomson Scattering Diagnostics in LHD
    Saito, Teruo
    Yamaguchi, Yuusuke
    Tatematsu, Yoshinori
    Kasa, Jun
    Kotera, Masaki
    Ikeuchi, Shinji
    Idehara, Toshitaka
    Kubo, Shin
    Shimozuma, Takashi
    Tanaka, Kenji
    Nishiura, Masaki
    2014 39TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ), 2014,
  • [7] Development of a High Power 300 GHz Band Gyrotron for Practical Use in Collective Thomson Scattering Diagnostics in LHD
    Saito, Teruo
    Kasa, Jun
    Yamaguchi, Yuusuke
    Tatematsu, Yoshinori
    Kotera, Masaki
    Kubo, Shin
    Shimozuma, Takashi
    Tanaka, Kenji
    Nishiura, Masaki
    2015 40TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER AND TERAHERTZ WAVES (IRMMW-THZ), 2015,
  • [8] Developments of equipment for sub-THz collective Thomson scattering in LHD
    Saito, Teruo
    Tanaka, Shunsuke
    Shinbayashi, Ryuji
    Hirobe, Takumi
    Yamaguchi, Yuusuke
    Fukunari, Masafumi
    Tatematsu, Yoshinori
    Ohkubo, Kunizo
    Kubo, Shin
    Shimozuma, Takashi
    Tanaka, Kenji
    Nishiura, Masaki
    2018 43RD INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ), 2018,
  • [9] Scattering volume in the collective Thomson scattering measurement using high power gyrotron in the LHD
    Kubo, S.
    Nishiura, M.
    Tanaka, K.
    Moseev, D.
    Ogasawara, S.
    Shimozuma, T.
    Yoshimura, Y.
    Igami, H.
    Takahashi, H.
    Tsujimura, T. I.
    Makino, R.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [10] Spectrum response and analysis of 77 GHz band collective Thomson scattering diagnostic for bulk and fast ions in LHD plasmas
    Nishiura, M.
    Kubo, S.
    Tanaka, K.
    Seki, R.
    Ogasawara, S.
    Shimozuma, T.
    Okada, K.
    Kobayashi, S.
    Mutoh, T.
    Kawahata, K.
    Watari, T.
    Saito, T.
    Tatematsu, Y.
    Korsholm, S. B.
    Salewski, M.
    NUCLEAR FUSION, 2014, 54 (02)