Accuracy of femoral rotational alignment in total knee arthroplasty using computer assisted navigation

被引:0
作者
Restrepo, Camilo [1 ]
Hozacic, William J. [1 ]
Orozco, Fabio [1 ]
Parvizi, Javad [1 ]
机构
[1] Thomas Jefferson Univ, Sch Med, Rothman Inst Orthoped, Philadelphia, PA 19107 USA
关键词
total knee arthroplasty; femoral rotation; computer assisted navigation; transepicondylar axis; Whiteside's line;
D O I
10.1080/10929080802045640
中图分类号
R61 [外科手术学];
学科分类号
摘要
Proper rotational alignment of components is crucial for the success of total knee arthroplasty (TKA). The traditional reference guides for assessment of femoral rotation include the posterior condylar axis, the anteroposterior axis, also known as Whiteside's line, and the transepicondylar axis (TEA). The fixed-angle posterior referencing system recommends that the rotational femoral cut be made at 3 degrees of external rotation. In a consecutive series of 100 patients undergoing TKA at our institution, the accuracy of these reference guides in determining the rotation of the femoral component was compared with that of a computerized navigation system. Although differences between the three reference methods were not statistically significant, the possibility of finding an outlier leading to excessive external or internal rotation of the femoral component when using a fixed posterior condyle reference guide mandates the use of other referencing methods to avoid this error. Using fixed posterior referencing, up to 17% of femoral components would have differed by more than 5 degrees from the anatomic reference landmarks (TEA, Whiteside's line). This degree of rotational malalignment could lead to knee instability and early failure.
引用
收藏
页码:167 / 172
页数:6
相关论文
共 19 条
  • [1] ANOUCHI YS, 1993, CLIN ORTHOP RELAT R, P170
  • [2] FEMORAL ROTATIONAL ALIGNMENT, BASED ON THE ANTEROPOSTERIOR AXIS, IN TOTAL KNEE ARTHROPLASTY IN A VALGUS KNEE - A TECHNICAL NOTE
    ARIMA, J
    WHITESIDE, LA
    MCCARTHY, DS
    WHITE, SE
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77 (09) : 1331 - 1334
  • [3] Barrack RL, 2001, CLIN ORTHOP RELAT R, P46
  • [4] BERGER RA, 1993, CLIN ORTHOP RELAT R, P40
  • [5] Malrotation causing patellofemoral complications after total knee arthroplasty
    Berger, RA
    Crossett, LS
    Jacobs, JJ
    Rubash, HE
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (356) : 144 - 153
  • [6] The posterior condylar angle in osteoarthritic knees
    Griffin, FM
    Insall, JN
    Scuderi, GR
    [J]. JOURNAL OF ARTHROPLASTY, 1998, 13 (07) : 812 - 815
  • [7] HUNGERFORD DS, 1985, CLIN ORTHOP RELAT R, P23
  • [8] HUNGERFORD DS, 1983, CLIN ORTHOP RELAT R, P95
  • [9] Determining femoral rotational alignment in total knee arthroplasty - Reliability of techniques
    Katz, MA
    Beck, TD
    Silber, JS
    Seldes, RM
    Lotke, PA
    [J]. JOURNAL OF ARTHROPLASTY, 2001, 16 (03) : 301 - 305
  • [10] Krackow K A, 1999, Am J Knee Surg, V12, P222