Gamma Knife irradiation method based on dosimetric controls to target small areas in rat brains

被引:5
作者
Constanzo, Julie [1 ]
Paquette, Benoit [1 ]
Charest, Gabriel [1 ]
Masson-Cote, Laurence [1 ,2 ]
Guillot, Mathieu [1 ,2 ]
机构
[1] Univ Sherbrooke, Dept Nucl Med & Radiobiol, Ctr Radiotherapy Res, Sherbrooke, PQ J1H 5N4, Canada
[2] Ctr Hosp Univ Sherbrooke, Dept Radiat Oncol, Sherbrooke, PQ J1H 5N4, Canada
关键词
brain irradiation; dosimetry; Gamma Knife; small-animal irradiation; stereotactic radiosurgery (SRS); FUNCTIONAL-CHANGES; RADIOSURGERY; SURGERY; FILM;
D O I
10.1118/1.4916659
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Targeted and whole-brain irradiation in humans can result in significant side effects causing decreased patient quality of life. To adequately investigate structural and functional alterations after stereotactic radiosurgery, preclinical studies are needed. The purpose of this work is to establish a robust standardized method of targeted irradiation on small regions of the rat brain. Methods: Euthanized male Fischer rats were imaged in a stereotactic bed, by computed tomography (CT), to estimate positioning variations relative to the bregma skull reference point. Using a rat brain atlas and the stereotactic bregma coordinates obtained from CT images, different regions of the brain were delimited and a treatment plan was generated. A single isocenter treatment plan delivering >= 100 Gy in 100% of the target volume was produced by Leksell GammaPlan using the 4 mm diameter collimator of sectors 4, 5, 7, and 8 of the Gamma Knife unit. Impact of positioning deviations of the rat brain on dose deposition was simulated by GammaPlan and validated with dosimetric measurements. Results: The authors' results showed that 90% of the target volume received 100 +/- 8 Gy and the maximum of deposited dose was 125 +/- 0.7 Gy, which corresponds to an excellent relative standard deviation of 0.6%. This dose deposition calculated with GammaPlan was validated with dosimetric films resulting in a dose-profile agreement within 5%, both in X- and Z-axes. Conclusions: The authors' results demonstrate the feasibility of standardizing the irradiation procedure of a small volume in the rat brain using a Gamma Knife. (C) 2015 American Association of Physicists in Medicine.
引用
收藏
页码:2311 / 2316
页数:6
相关论文
共 23 条
  • [1] [Anonymous], 1983, MED PHYS, V10, P741
  • [2] [Anonymous], 2011, GAMMA KNIFE RADIOSUR
  • [3] [Anonymous], MED PHYS
  • [4] Dosimetric characterization and use of GAFCHROMIC EBT3 film for IMRT dose verification
    Borca, Valeria Casanova
    Pasquino, Massimo
    Russo, Giuliana
    Grosso, Pierangelo
    Cante, Domenico
    Sciacero, Piera
    Girelli, Giuseppe
    La Porta, Maria Rosa
    Tofani, Santi
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (02): : 158 - 171
  • [5] Radiosurgery of the rat hippocampus: Magnetic resonance imaging, neurophysiological, histological, and behavioral studies
    Brisman, JL
    Cole, AJ
    Cosgrove, GR
    Thornton, AF
    Rabinov, J
    Bussiere, M
    Bradley-Moore, M
    Hedley-Whyte, T
    Chapman, PH
    [J]. NEUROSURGERY, 2003, 53 (04) : 951 - 961
  • [6] Polymer gel in rat skull to assess the accuracy of a new rat stereotactic device for use with the Gamma Knife
    Charest, Gabriel
    Mathieu, David
    Lepage, Martin
    Fortin, David
    Paquette, Benoit
    Sanche, Leon
    [J]. ACTA NEUROCHIRURGICA, 2009, 151 (06) : 677 - 684
  • [7] Microbeam radiation therapy: Tissue dose penetration and BANG-gel dosimetry of thick-beams' array interlacing
    Dilmanian, F. Avraham
    Romanelli, Pantaleo
    Zhong, Zhong
    Wang, Ruiliang
    Wagshul, Mark E.
    Kalef-Ezra, John
    Maryanski, Marek J.
    Rosen, Eliot M.
    Anschel, David J.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2008, 68 (03) : S129 - S136
  • [8] Development of a small-animal focal brain irradiation model to study radiation injury and radiation-injury modifiers
    Hideghety, Katalin
    Plangar, Imola
    Man, Imola
    Fekete, Gabor
    Nagy, Zoltan
    Volford, Gabor
    Tokes, Tuende
    Szabo, Emilia
    Szabo, Zoltan
    Brinyiczki, Kitti
    Mozes, Petra
    Nemeth, Istvan
    [J]. INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2013, 89 (08) : 645 - 655
  • [9] Transcriptomic analysis of rat brain tissue following gamma knife surgery: Early and distinct bilateral effects in the un-irradiated striatum
    Hirano, Misato
    Shibato, Junko
    Rakwal, Randeep
    Kouyama, Nobuo
    Katayama, Yoko
    Hayashi, Motohiro
    Masuo, Yoshinori
    [J]. MOLECULES AND CELLS, 2009, 27 (02) : 263 - 268
  • [10] Dose-related effects of single focal irradiation in the medial temporal lobe structures in rats - Magnetic resonance imaging and histological study
    Ishikawa, S
    Otsuki, T
    Kaneki, M
    Jokura, H
    Yoshimoto, T
    [J]. NEUROLOGIA MEDICO-CHIRURGICA, 1999, 39 (01): : 1 - 7