Enhancement of phase separation using a drop coalescer in an aqueous two-phase system

被引:8
作者
Ban, T [1 ]
Shibata, M [1 ]
Kawaizumi, F [1 ]
Nii, S [1 ]
Takahashi, K [1 ]
机构
[1] Nagoya Univ, Dept Chem Engn, Chikusa Ku, Nagoya, Aichi 4648603, Japan
来源
JOURNAL OF CHROMATOGRAPHY B | 2001年 / 760卷 / 01期
关键词
aqueous two-phase systems; drop coalescer; proteins;
D O I
10.1016/S0378-4347(01)00253-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The effect of a drop coalescer on phase separation in a PEG/salt aqueous two-phase system (ATPS) in the absence and presence of protein has been investigated. Raschig rings of ceramic, PTFE and glass were used as a drop coalescer in order to separate the mixture into two phases. Among the three materials PTFE is the most effective in coalescing the dispersed drops, with the throughput with PTFE being twice that without the coalescer. Random packing gives good results for phase separation. Two types of fiber mesh coated with PTFE were also used as drop coalescers, one in a spirally folded form and the other in a three-dimensional lattice-form. Throughput in the PEG/salt system with the three-dimensional lattice-form is 1.2 times as high as that with the spirally folded form. Throughput with the coalescer formed by compiling PTFE Raschig rings and fiber mesh in lattice form is 1.6 and 1.2 times as high as the case of separate use of the fiber mesh and the PTFE Raschig rings, respectively. The hydrophobic surface of PTFE in the compiled coalescer has no significant effect on the recovery fraction of the protein in ATPS. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:65 / 72
页数:8
相关论文
共 50 条
  • [31] Separation of glycomacropeptide (a functional protein material) by aqueous two-phase systems
    Wu, Jiang
    Wang, Yu
    Huang, Liang
    FUNCTIONAL MATERIALS AND NANOTECHNOLOGY, 2012, 496 : 185 - 188
  • [32] Aqueous two-phase systems: a novel approach for the separation of proteose peptones
    Isgrove, FH
    Williams, RJH
    Niven, GW
    Andrews, AT
    JOURNAL OF CHROMATOGRAPHY B, 1998, 711 (1-2): : 91 - 96
  • [33] Reversibly soluble macroaffinity ligand in aqueous two-phase separation of enzymes
    Teotia, S
    Gupta, MN
    JOURNAL OF CHROMATOGRAPHY A, 2001, 923 (1-2) : 275 - 280
  • [34] Kinetics of phase separation under different process and design parameters in aqueous two-phase systems
    Solano-Castillo, C
    Rito-Palomares, M
    JOURNAL OF CHROMATOGRAPHY B, 2000, 743 (1-2): : 195 - 201
  • [35] Efficient separation of curcumin using tetra butyl phosphonium bromide/carbohydrates (sorbitol, fructose) aqueous two-phase system
    Ghasemzadeh, Behrad
    Shahriari, Shahla
    Pazuki, Gholamreza
    FLUID PHASE EQUILIBRIA, 2019, 498 : 51 - 58
  • [36] Separation and purification of enveloped and non-enveloped viruses from water samples using an aqueous two-phase system
    Hao, Xiaotang
    Chen, Jiehan
    Xu, Mengyuan
    Zheng, Huiying
    Li, Xi
    Wang, Mei
    Liu, Tiantian
    PROCESS BIOCHEMISTRY, 2022, 119 : 58 - 67
  • [37] Theory of phase formation in aqueous two-phase systems
    Cabezas, H
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 680 (1-2): : 3 - 30
  • [38] EXTRACTION OF PAPAIN BY AN IONIC LIQUID-BASED AQUEOUS TWO-PHASE SYSTEM
    Pang, Jingyu
    Ji, Haiyan
    Liu, Jianjun
    Chao, Yanhong
    He, Lining
    Han, Changri
    Zhu, Wenshuai
    Li, Huaming
    FRESENIUS ENVIRONMENTAL BULLETIN, 2015, 24 (4B): : 1579 - 1584
  • [39] Separation and purification of glucoamylase in aqueous two-phase systems by a two-step extraction
    Minami, NM
    Kilikian, BV
    JOURNAL OF CHROMATOGRAPHY B, 1998, 711 (1-2): : 309 - 312
  • [40] Cold cataracts: a naturally occurring aqueous two-phase system
    Petitt, P
    Forciniti, D
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2000, 743 (1-2): : 431 - 441