Real-Time Switched Model Predictive Control for a Cyber-Physical Wind Turbine Emulator

被引:23
作者
Moness, Mohammed [1 ]
Moustafa, Ahmed Mahmoud [1 ]
机构
[1] Minia Univ, Dept Comp & Syst Engn, Fac Engn, Al Minya 61111, Egypt
关键词
Real-time systems; Aerodynamics; Generators; Computational modeling; Mathematical model; Damping; Poles and towers; Cyber-physical system (CPS); emulation; real-time optimal control; switched model predictive control (SMPC); wind energy; CHALLENGES; GENERATOR;
D O I
10.1109/TII.2019.2937549
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The high complexity and nonlinearity of wind turbine (WT) systems impose the utilization of rigorous control methods such as model predictive control (MPC). MPC algorithms are computationally intensive requiring investigation of real-time implementability and feasibility in addition to control performance metrics. In this article, a switched model predictive controller (SMPC) is developed, implemented, and investigated for control objectives performance and real-time metrics. This article has two main contributions. First, embedded real-time SMPC is developed using qpOASES as an embedded solver for the online optimal control problem. Second, a cyber-physical real-time emulator for variable-speed variable-pitch utility-scale WT is developed and implemented on an xPC target machine using a high-fidelity linear parameter-varying model. The SMPC is evaluated on the fatigue, aerodynamics, structures, and turbulence (FAST) design code and the real-time emulator. The analysis and investigation of results highlight the feasibility and capability of SMPC for handling control objectives of WT systems within real-time using short control periods.
引用
收藏
页码:3807 / 3817
页数:11
相关论文
共 46 条
[1]  
Adegas FD, 2013, P AMER CONTR CONF, P653
[2]   Switched Model Predictive Control for Improved Transient and Steady-State Performance [J].
Aguilera, Ricardo P. ;
Lezana, Pablo ;
Quevedo, Daniel E. .
IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2015, 11 (04) :968-977
[3]  
Alessio A, 2009, LECT NOTES CONTR INF, V384, P345, DOI 10.1007/978-3-642-01094-1_29
[4]  
[Anonymous], 2018, TECH REP
[5]  
[Anonymous], TECH REP
[6]  
[Anonymous], THESIS
[7]  
Bir G. S., 2010, Tech. Rep. NREL/TP-500-44327
[8]   Legionella infection risk from domestic hot water [J].
Borella, P ;
Montagna, MT ;
Romano-Spica, V ;
Stampi, S ;
Stancanelli, G ;
Triassi, M ;
Neglia, R ;
Marchesi, I ;
Fantuzzi, G ;
Tatò, D ;
Napoli, C ;
Quaranta, G ;
Laurenti, P ;
Leoni, E ;
De Luca, G ;
Ossi, C ;
Moro, M ;
D'Alcalà, GR .
EMERGING INFECTIOUS DISEASES, 2004, 10 (03) :457-464
[9]   Nonlinear control of variable-speed wind turbines for generator torque limiting and power optimization [J].
Boukhezzar, B. ;
Siguerdidjane, H. ;
Hand, M. Maureen .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (04) :516-530
[10]   Vehicle Yaw Stability Control by Coordinated Active Front Steering and Differential Braking in the Tire Sideslip Angles Domain [J].
Di Cairano, Stefano ;
Tseng, Hongtei Eric ;
Bernardini, Daniele ;
Bemporad, Alberto .
IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2013, 21 (04) :1236-1248