Retention Mechanism of Proteins in Hydroxyapatite Chromatography - Multimodal Interaction Based Protein Separations: A Model Study

被引:21
作者
Itoh, Daisuke [1 ]
Yoshimoto, Noriko [1 ]
Yamamoto, Shuichi [1 ]
机构
[1] Yamaguchi Univ, Bioproc Engn Lab, Grad Sch Med, Biomed Engn Ctr YUBEC, Ube, Yamaguchi 7558611, Japan
关键词
Hydroxyapatite chromatography; linear gradient elution; protein retention; binding site; LGE; LF; ION-EXCHANGE CHROMATOGRAPHY; HUMAN-IGG STRUCTURE; ISOELECTRIC POINTS; MOLECULAR-WEIGHTS; ANTIBODIES; RESOLUTION; TIME;
D O I
10.2174/1389203718666171024122106
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Background: Retention mechanism of proteins in hydroxyapatite chromatography (HAC) was investigated by linear gradient elution experiments (LGE). Materials and Methods: Several mobile phase (buffer) solution strategies and solutes were evaluated in order to probe the relative contributions of two adsorption sites of hydroxyapatite (HA) particles, C-site due to Ca (metal affinity) and P-site due to PO4 (cation-exchange). When P-site was blocked, two basic proteins, lysozyme (Lys) and ribonuclease A(RNase), were not retained whereas cytochrome C(Cyt C) and lactoferrin (LF) were retained and also retention of acidic proteins became stronger as the repulsion due to P-site was eliminated. The number of the binding site B values determined from LGE also increased, which also showed reduction of repulsion forces. Conclusion: The selectivity (retention) of four basic proteins (RNase, Lys, Cyt C, LF) in HAC was different from that in ion-exchange chromatography. Moreover, it was possible to tune the selectivity by using NaCl gradient.
引用
收藏
页码:75 / 81
页数:7
相关论文
共 37 条
[1]   ABNORMAL SOLUBILITY BEHAVIOR OF BETA-LACTOGLOBULIN - SALTING-IN BY GLYCINE AND NACL [J].
ARAKAWA, T ;
TIMASHEFF, SN .
BIOCHEMISTRY, 1987, 26 (16) :5147-5153
[2]   pH Transients in hydroxyapatite chromatography columns-Experimental evidence and phenomenological modeling [J].
Bankston, Theresa E. ;
Dattolo, Laura ;
Carta, Giorgio .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (14) :2123-2131
[3]  
Bernardi G., 1971, METHODS ENZYMOLOGY, V22, P325, DOI [10.1016/0076-6879(71)22031-0, DOI 10.1016/0076-6879(71)22031-0]
[4]  
Carta G., 2010, PROTEIN CHROMATOGRAP, P125, DOI 10.1002/9783527630158.ch4
[5]   The distinctive separation attributes of mixed-mode resins and their application in monoclonal antibody downstream purification process [J].
Chen, Jie ;
Tetrault, Jen ;
Zhang, Yanyu ;
Wasserman, Andy ;
Conley, Greg ;
DiLeo, Mike ;
Haimes, Elliot ;
Nixon, Andrew E. ;
Ley, Arthur .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (02) :216-224
[6]   PROTEIN CHROMATOGRAPHY ON HYDROXYAPATITE COLUMNS [J].
Cummings, Larry J. ;
Snyder, Mark A. ;
Brisack, Kimberly .
GUIDE TO PROTEIN PURIFICATION, SECOND EDITION, 2009, 463 :387-404
[7]   Isolation and purification of recombinant proteins, antibodies and plasmid DNA with hydroxyapatite chromatography [J].
Freitag, Ruth ;
Hilbrig, Frank .
BIOTECHNOLOGY JOURNAL, 2012, 7 (01) :90-102
[8]  
Gagnon P, 2008, PROCESS SCALE PURIFI, V6, P125
[9]  
Gagnon P, 1996, VALIDATED BIOSYSTEMS, P87
[10]  
Gagnon P, COMMUNICATION