MICRODOSIMETRIC MEASUREMENT OF SECONDARY RADIATION IN THE PASSIVE SCATTERED PROTON THERAPY ROOM OF iTHEMBA LABS USING A TISSUE-EQUIVALENT PROPORTIONAL COUNTER

被引:1
作者
Chiriotti, S. [1 ]
Parisi, A. [1 ]
Vanhavere, F. [1 ]
De Saint-Hubert, M. [1 ]
Vandevoorde, C. [2 ]
Slabbert, J. [2 ]
Beukes, P. [2 ]
de Kock, E. [2 ]
Symons, J. [2 ]
机构
[1] SCK CEN, Belgian Nucl Res Ctr, Boeretang 200, Mol, Belgium
[2] NRF iThemba LABS, Cape Town, South Africa
关键词
DOSE-EQUIVALENT; CALIBRATION; RISK;
D O I
10.1093/rpd/ncy056
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Measurements of the dose equivalent at different distances from the isocenter of the proton therapy center at iThemba LABS were previously performed with a tissue-equivalent proportional counter (TEPC). These measurements showed that the scattered radiation levels were one or two orders of magnitude higher in comparison to other passive scattering delivery systems. In order to reduce these radiation levels, additional shielding was installed shortly after the measurements were done. Therefore, the aim of this work is to quantify and assess the reduction of the secondary doses delivered in the proton therapy room at iThemba LABS after the installation of the additional shielding. This has been performed by measuring microdosimetric spectra with a TEPC at 11 locations around the isocenter when a clinical modulated beam of 200 MeV proton was impinging onto a water phantom placed at the isocenter.
引用
收藏
页码:252 / 257
页数:6
相关论文
共 14 条
  • [1] Secondary dose exposures during 200 MeV proton therapy
    Binns, PJ
    Hough, JH
    [J]. RADIATION PROTECTION DOSIMETRY, 1997, 70 (1-4) : 441 - 444
  • [2] FWT, 2011, ENV RAD MON 5 INCH T
  • [3] Icru, 1983, ICRU REPORT 36
  • [4] International Commission on Radiation Units and Measurements, 1986, 40 ICRU
  • [5] Jeyasugiththan J, 2013, PROCEEDINGS OF SAIP2013: THE 58TH ANNUAL CONFERENCE OF THE SOUTH AFRICAN INSTITUTE OF PHYSICS, P260
  • [6] Proton beam therapy
    Levin, WP
    Kooy, H
    Loeffler, JS
    DeLaney, TF
    [J]. BRITISH JOURNAL OF CANCER, 2005, 93 (08) : 849 - 854
  • [7] LINEAL ENERGY CALIBRATION OF A SPHERICAL TEPC
    Moro, D.
    Chiriotti, S.
    Conte, V.
    Colautti, P.
    Grosswendt, B.
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 166 (1-4) : 233 - 237
  • [8] Assessing the risk of second malignancies after modern radiotherapy
    Newhauser, Wayne D.
    Durante, Marco
    [J]. NATURE REVIEWS CANCER, 2011, 11 (06) : 438 - 448
  • [9] The risk of developing a second cancer after receiving craniospinal proton irradiation
    Newhauser, Wayne D.
    Fontenot, Jonas D.
    Mahajan, Anita
    Kornguth, David
    Stovall, Marilyn
    Zheng, Yuanshui
    Taddei, Phillip J.
    Mirkovic, Dragan
    Mohan, Radhe
    Cox, James D.
    Woo, Shiao
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (08) : 2277 - 2291
  • [10] Paquet F., 2017, Annals of the ICRP, V46, P1, DOI [10.1016/j.icrp.2013.01.001, 10.1016/j.icrp.2008.08.001, 10.1177/0146645317734963]