Modulation transfer function of intraocular collamer lens with a central artificial hole

被引:41
作者
Uozato, Hiroshi [1 ,2 ]
Shimizu, Kimiya [2 ,3 ]
Kawamorita, Takushi [1 ,2 ]
Ohmoto, Fumiko [2 ,3 ]
机构
[1] Kitasato Univ, Sch Allied Hlth Sci, Dept Orthopt & Visual Sci, Minami Ku, Sagamihara, Kanagawa 2520373, Japan
[2] Kitasato Univ, Grad Sch Med Sci, Dept Ophthalmol & Visual Sci, Sagamihara, Kanagawa 2520373, Japan
[3] Kitasato Univ, Sch Med, Dept Ophthalmol, Sagamihara, Kanagawa 2520373, Japan
关键词
Modulation transfer function; Pupil size; Phakic IOL; ICL; Hole ICL; PHAKIC IOL ICL; CATARACT DEVELOPMENT; IN-VITRO; EYES; IMPLANTATION; PERFORMANCE; SURGERY; MYOPIA;
D O I
10.1007/s00417-010-1602-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
A modified implantable collamer lens (ICL) with a central hole (diameter 0.36 mm), "Hole-ICL", was created to improve aqueous humour circulation. The aim of this study is to investigate the effects of ICL power and the relationship between pupil size and modulation-transfer functions (MTFs) in a Hole-ICL in vitro. The ICL and intraocular lens (IOL) studied were the Collamer ICL (Model ICM, STAAR Surginal) and the monofocal IOL AF-1 (VA-60BBR, HOYA). The ICLs' powers were -20.0 diopters (D), -10.0 D, -5.0 D, +3.0 D, and +10.0 D. A modified ICL with a central hole (diameter 0.36 mm), "Hole-ICL", was created. The monofocal IOL, which was used as an artificial crystalline lens, was +30.0 D in power, and it was 13.0 mm in length with an optic diameter of 6.0 mm. The line-spread function (LSF) was recorded with the OPAL Vector System (Image Science Ltd.), and a model eye (Menicon Co.) was used that consisted of a wet cell. A conventional ICL or Hole-ICL was placed in the posterior chamber of the model eye. The MTF was calculated from the LSF using fast Fourier transform techniques. Furthermore, we investigated the relationship between pupil size and the MTF of the ICL for -5.0 D. The sizes of the effective aperture were 2.0, 3.0, 4.0, and 5.0 mm. The in-focus contrasts of the conventional ICL at 100 cyc/mm for a 3.0-mm effective aperture were 37%, 40%, 39%, 38%, and 39% for -20.0 D, -10.0 D, -5.0 D, +3.0 D, and +10.0 D respectively. The in-focus contrasts of the Hole-ICL at 100 cyc/mm for a 3.0-mm effective aperture were 37%, 40%, 39%, 38%, and 38% for -20.0 D, -10.0 D, -5.0 D, +3.0 D, and +10.0 D respectively. The results for a 2.0-mm effective diameter showed that the in-focus MTF in the Hole-ICL was lower than in the conventional ICL, although the difference was small. These results suggest that differences in MTF between the Hole-ICL and the conventional ICL for various ICL powers and effective pupil diameters were small and clinically negligible.
引用
收藏
页码:1081 / 1085
页数:5
相关论文
共 20 条
[1]   Three-year follow-up of subjective vault following myopic implantable collamer lens implantation [J].
Alfonso, Jose F. ;
Lisa, Carlos ;
Abdelhamid, A. ;
Fernandes, Paulo ;
Jorge, Jorge ;
Montes-Mico, Robert .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (12) :1827-1835
[2]   Cataract surgery in highly myopic eyes corrected by phakic anterior chamber angle-supported lenses [J].
Alió, JL ;
de la Hoz, F ;
Ruiz-Moreno, JM ;
Salem, TF .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (09) :1303-1311
[3]   OPTICAL AND RETINAL FACTORS AFFECTING VISUAL RESOLUTION [J].
CAMPBELL, FW ;
GREEN, DG .
JOURNAL OF PHYSIOLOGY-LONDON, 1965, 181 (03) :576-+
[4]   The prospects for super-acuity: limits to visual performance after correction of monochromatic ocular aberration [J].
Charman, WN ;
Chateau, N .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2003, 23 (06) :479-493
[5]   Metaanalysis of cataract development after phakic intraocular lens surgery [J].
Chen, Li-Ju ;
Chang, Yun-Jau ;
Kuo, Jonathan C. ;
Rajagopal, Rama ;
Azar, Dimitri T. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (07) :1181-1200
[6]   Posterior chamber myopia lenses in phakic eyes [J].
Fechner, PU ;
Haigis, W ;
Wichmann, W .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 (02) :178-182
[7]   Changes in the crystalline lens resulting from insertion of a phakic IOL (ICL) into the porcine eye [J].
Fujisawa, Kunitoshi ;
Shimizu, Kimiya ;
Uga, Shigekazu ;
Suzuki, Masanobu ;
Nagano, Koichi ;
Murakami, Yuuki ;
Goseki, Hiroko .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 245 (01) :114-122
[8]   Safety of posterior chamber phakic intraocular lenses for the correction of high myopia -: Anterior segment changes after posterior chamber phakic intraocular lens implantation [J].
Jiménez-Alfaro, I ;
del Castillo, JMB ;
García-Feijoó, J ;
de Bernabé, JGG ;
de la Iglesia, JMS .
OPHTHALMOLOGY, 2001, 108 (01) :90-99
[9]   Optical Performance in ReZoom and Array Multifocal Intraocular Lenses In Vitro [J].
Kawamorita, Takushi ;
Uozato, Hiroshi ;
Aizawa, Daisuke ;
Kamiya, Kazutaka ;
Shimizu, Kimiya .
JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (05) :467-469
[10]   Cataract development associated with collagen copolymer posterior chamber phakic intraocular lenses: Clinicopathological correlation [J].
Khalifa, Yousuf M. ;
Moshirfar, Majid ;
Mifflin, Mark D. ;
Kamae, Kandon ;
Mamalis, Nick ;
Werner, Liliana .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (10) :1768-1774