Paclitaxel-iopromide coated balloon followed by "bail-out" bare metal stent in porcine iliofemoral arteries: first report on biological effects in peripheral circulation
被引:10
作者:
Milewski, Krzysztof
论文数: 0引用数: 0
h-index: 0
机构:
Cardiovasc Res Fdn, Skirball Ctr Cardiovasc Res, Orangeburg, NY 10962 USACardiovasc Res Fdn, Skirball Ctr Cardiovasc Res, Orangeburg, NY 10962 USA
Milewski, Krzysztof
[1
]
Tellez, Armando
论文数: 0引用数: 0
h-index: 0
机构:
Cardiovasc Res Fdn, Skirball Ctr Cardiovasc Res, Orangeburg, NY 10962 USACardiovasc Res Fdn, Skirball Ctr Cardiovasc Res, Orangeburg, NY 10962 USA
Tellez, Armando
[1
]
Aboodi, Michael S.
论文数: 0引用数: 0
h-index: 0
机构:
Cardiovasc Res Fdn, Skirball Ctr Cardiovasc Res, Orangeburg, NY 10962 USACardiovasc Res Fdn, Skirball Ctr Cardiovasc Res, Orangeburg, NY 10962 USA
Aboodi, Michael S.
[1
]
Conditt, Gerard B.
论文数: 0引用数: 0
h-index: 0
机构:
Cardiovasc Res Fdn, Skirball Ctr Cardiovasc Res, Orangeburg, NY 10962 USACardiovasc Res Fdn, Skirball Ctr Cardiovasc Res, Orangeburg, NY 10962 USA
Conditt, Gerard B.
[1
]
Yi, Geng Hua
论文数: 0引用数: 0
h-index: 0
机构:
Cardiovasc Res Fdn, Skirball Ctr Cardiovasc Res, Orangeburg, NY 10962 USACardiovasc Res Fdn, Skirball Ctr Cardiovasc Res, Orangeburg, NY 10962 USA
Yi, Geng Hua
[1
]
Thim, Troels
论文数: 0引用数: 0
h-index: 0
机构:
Aarhus Univ Hosp, Dept Cardiol, Skejby, DenmarkCardiovasc Res Fdn, Skirball Ctr Cardiovasc Res, Orangeburg, NY 10962 USA
Thim, Troels
[2
]
Stenoien, Mark
论文数: 0引用数: 0
h-index: 0
机构:
MEDRAD Intervent Possis, Indianola, PA USACardiovasc Res Fdn, Skirball Ctr Cardiovasc Res, Orangeburg, NY 10962 USA
Stenoien, Mark
[3
]
McGregor, Jennifer C.
论文数: 0引用数: 0
h-index: 0
机构:
Cardiovasc Res Fdn, Skirball Ctr Cardiovasc Res, Orangeburg, NY 10962 USACardiovasc Res Fdn, Skirball Ctr Cardiovasc Res, Orangeburg, NY 10962 USA
McGregor, Jennifer C.
[1
]
Gray, William A.
论文数: 0引用数: 0
h-index: 0
机构:
Cardiovasc Res Fdn, Skirball Ctr Cardiovasc Res, Orangeburg, NY 10962 USACardiovasc Res Fdn, Skirball Ctr Cardiovasc Res, Orangeburg, NY 10962 USA
Gray, William A.
[1
]
Virmani, Renu
论文数: 0引用数: 0
h-index: 0
机构:
CVPath Inst Inc, Gaithersburg, MD USACardiovasc Res Fdn, Skirball Ctr Cardiovasc Res, Orangeburg, NY 10962 USA
Virmani, Renu
[4
]
Granada, Juan F.
论文数: 0引用数: 0
h-index: 0
机构:
Cardiovasc Res Fdn, Skirball Ctr Cardiovasc Res, Orangeburg, NY 10962 USACardiovasc Res Fdn, Skirball Ctr Cardiovasc Res, Orangeburg, NY 10962 USA
Granada, Juan F.
[1
]
Kaluza, Grzegorz L.
论文数: 0引用数: 0
h-index: 0
机构:
Cardiovasc Res Fdn, Skirball Ctr Cardiovasc Res, Orangeburg, NY 10962 USACardiovasc Res Fdn, Skirball Ctr Cardiovasc Res, Orangeburg, NY 10962 USA
Kaluza, Grzegorz L.
[1
]
机构:
[1] Cardiovasc Res Fdn, Skirball Ctr Cardiovasc Res, Orangeburg, NY 10962 USA
Aims: Despite recent abundance of data on drug-coated balloon technology, the biological effects of paclitaxel coated balloon (PCB) treatment followed by bare metal stent (BMS) implantation in peripheral arteries (simulating bail-out stenting, a common clinical scenario), have not been published. Methods and results: PCB technology containing a paclitaxel-iopromide coating and identical iopromide-coated controls (without paclitaxel) were used in 16 porcine ilio-femoral arteries. The biological effects of inflating one (PCBx1) or two sequential (PCBx2) paclitaxel coated balloons before BMS implantation were compared to the single application of a control balloon (CCBx1; contrast coated balloons). At 30 days PCBx2 displayed significantly reduced late lumen loss by angiography (58% reduction vs. CCBx1; p=0.04) and neointimal area by histomorphometry (35% reduction vs. CCBx1 and 30% vs. PCBx1; p=0.02). Similarly, percent area stenosis in the PCBx2 group was reduced by 45% as compared to CCBx1 and PCBx1 (p=0.04). At this time, all parameters of vessel wall healing (including injury score, inflammation, and endothelialisation) following drug coated balloon treatment were comparable to the control group. Conclusions: Paclitaxel delivery to porcine ilio-femorals using PCB followed by BMS implantation effectively decreased neointimal proliferation. More extensive and prolonged proliferative response of the vessel after stenting (necessitating higher drug dose) could potentially explain the undetectable effect of PEBx1 relative to CCBx1 in this pilot study. Histological analysis confirmed the safety and biocompatibility of PCB technology.