Optimal threshold in low-dose CT quantification of emphysema

被引:7
|
作者
Cao, Xianxian [1 ]
Jin, Chenwang [1 ]
Tan, Tao [2 ]
Guo, Youmin [1 ]
机构
[1] Xi An Jiao Tong Univ, Dept Med Imaging, Affiliated Hosp 1, Xian 710061, Peoples R China
[2] Eindhoven Univ Technol, Dept Math & Comp Sci, Eindhoven, Netherlands
基金
美国国家卫生研究院;
关键词
Chronic obstructive pulmonary disease; Low-dose computed tomography; Emphysema; Quantitative threshold; COMPUTED DENSITY; LUNG; MORPHOMETRY; PROTOCOLS;
D O I
10.1016/j.ejrad.2020.109094
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Low-dose CT is now widely used in the screening of lung cancer and the detection of pulmonary nodules. There has also been increasing interest in using Low-dose CT for evaluating emphysema. In conventional dose CT, the threshold of -950HU is a common threshold for density-based emphysema quantification for worldwide population. However, the optimal threshold for assessing emphysema at low-dose CT has not been determined. The purpose of this study is to determine the optimal threshold for low-dose CT quantification of emphysema for Chinese population. Materials and methods: In this study, 548 low-dose chest CT examinations acquired from different subjects (119 none, 49 mild, 163 moderate, 152 severe, and 65 very severe obstruction) are collected. At the level of the entire lung and individual lobes, the extent of emphysema was quantified by the percentage of the low attenuation area (LAA%) at a wide range of thresholds from -850HU to -1000HU. Both Pearson and Spearman's rank correlation coefficients were used to assess the correlations between 1) LAA% and pulmonary functions and 2) LAA% and the five-category classification. The statistical significance of the difference between correlation coefficients were evaluated using Steiger'Z test. Results: LAA% had a good correlation with both pulmonary function (vertical bar r vertical bar = 0.1 -0.600, p < 0.001) and the five-category classification (r = 0.163-0.602, p < 0.001) in both the entire lung and individual lobes under different thresholds. The highest correlation coefficient is obtained at -940HU instead of -950HU. Conclusion: Low-dose CT can be used for quantitative assessment of emphysema, and the threshold of -940HU is a suitable threshold for quantifying emphysema in low-dose CT images for Chinese population.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Emphysema Quantification Using Ultralow-Dose CT With Iterative Reconstruction and Filtered Back Projection
    Nishio, Mizuho
    Koyama, Hisanobu
    Ohno, Yoshiharu
    Negi, Noriyuki
    Seki, Shinichiro
    Yoshikawa, Takeshi
    Sugimura, Kazuro
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 206 (06) : 1184 - 1192
  • [42] Low-dose lung CT: Optimizing diagnostic radiation dose - A phantom study
    Zellner, Michael
    Tschauner, Sebastian
    Weyland, Mathias S.
    Hotz, Peter Eggenberger
    Scheidegger, Stephan
    Kellenberger, Christian J.
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2024, 13
  • [43] Quantitative Emphysema on Low-Dose CT Imaging of the Chest and Risk of Lung Cancer and Airflow Obstruction An Analysis of the National Lung Screening Trial
    Labaki, Wassim W.
    Xia, Meng
    Murray, Susan
    Hatt, Charles R.
    Al-Abcha, Abdullah
    Ferrera, Michael C.
    Meldrum, Catherine A.
    Keith, Lauren A.
    Galban, Craig J.
    Arenberg, Douglas A.
    Curtis, Jeffrey L.
    Martinez, Fernando J.
    Kazerooni, Ella A.
    Han, MeiLan K.
    CHEST, 2021, 159 (05) : 1812 - 1820
  • [44] Longitudinal quantitative low-dose CT in COPD: ready for use?
    Kauczor, Hans-Ulrich
    Heussel, Claus Peter
    Herth, Felix J. F.
    LANCET RESPIRATORY MEDICINE, 2013, 1 (02) : 95 - 96
  • [45] LOW-DOSE HIGH-RESOLUTION CT OF LUNG PARENCHYMA
    ZWIREWICH, CV
    MAYO, JR
    MULLER, NL
    RADIOLOGY, 1991, 180 (02) : 413 - 417
  • [46] Pulmonary nodules: Experimental and clinical studies at low-dose CT
    Diederich, S
    Lenzen, H
    Windmann, R
    Puskas, Z
    Yelbuz, TM
    Henneken, S
    Klaiber, T
    Eameri, M
    Roos, N
    Peters, PE
    RADIOLOGY, 1999, 213 (01) : 289 - 298
  • [47] Low-Dose CT Image Reconstruction With a Deep Learning Prior
    Park, Hyoung Suk
    Kim, Kyungsang
    Jeon, Kiwan
    IEEE ACCESS, 2020, 8 : 158647 - 158655
  • [48] Low-dose CT of postoperative pelvic fractures: a comparison with radiography
    Eriksson, Thomas
    Berg, Per
    Olerud, Claes
    Shalabi, Adel
    Hanni, Mari
    ACTA RADIOLOGICA, 2019, 60 (01) : 85 - 91
  • [49] SELF-SUPERVISED TRAINING FOR LOW-DOSE CT RECONSTRUCTION
    Unal, Mehmet Ozan
    Ertas, Metin
    Yildirim, Isa
    2021 IEEE 18TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2021, : 69 - 72
  • [50] Low-dose CT of the lung: potential value of iterative reconstructions
    Stephan Baumueller
    Anna Winklehner
    Christoph Karlo
    Robert Goetti
    Thomas Flohr
    Erich W. Russi
    Thomas Frauenfelder
    Hatem Alkadhi