Geometry of laparoscopic suturing and knotting techniques

被引:51
|
作者
Frede, T [1 ]
Stock, C [1 ]
Renner, C [1 ]
Budair, Z [1 ]
Abdel-Salam, Y [1 ]
Rassweiler, J [1 ]
机构
[1] Klinikum Heilbronn, Dept Urol, D-74078 Heilbronn, Germany
关键词
D O I
10.1089/end.1999.13.191
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background: Spatial limitation, together with a fixed trocar position, restricted handling, and movement of the instruments, is inevitably associated with reconstructive laparoscopy and retroperitoneoscopy. This problem includes not only suturing technique and instruments but also geometric factors of endoscopic reconstruction, such as optimal distances between the working trocars, length of instruments, and angles between the instruments and the object. We present an experimental access to determine the specific impact of these factors on reconstructive laparoscopy. Materials and Methods: In an in vitro model, end-to-end anastomoses of porcine intestine were performed using a standardized intracorporeal suturing technique. Suturing was performed without and after training in reconstructive surgery with variation of the following geometric factors: (1) the distance between the working trocars (between 6 and 12 cm); (2) the position of the object (lateral right, medially, lateral left); (3) the camera position (medially, lateral right, lateral left); (4) the angle between the instruments and a horizontal line (15 degrees, 55 degrees, 90 degrees); (5) the intracorporeal length of instruments (between 10 and 25 cm); and (6) narrowed space available for the instruments (between 4 and 25 cm). Results: Continual training decreased the time required for suturing between 30% to 50%. Training decreased the time required for nonsuturing activities between 50% and 70% but the time required for suturing activities only between 20% and 45%. If the space between instruments and camera was limited, shifting the camera into a lateral position simplified the procedure of intracorporeal suturing. Angles of <55 degrees between instruments and the horizontal line simplified laparoscopic suturing, as did angles of <45 degrees between the instruments. In cases of maximally narrowed space (diameter of 4 cm), a suture filament length of <10 cm decreased the time required by 30%. Conclusion: We suggest an isosceles triangle between the instruments with an angle between 25 degrees and 45 degrees and an angle of <55 degrees between the instruments and the horizontal line as the optimal geometry for intracorporeal suturing, These data should be considered when planning a reconstructive laparoscopic procedure (i.e., alignment of trocars, table position). However, further studies are required to confirm these preliminary results.
引用
收藏
页码:191 / 198
页数:8
相关论文
共 50 条
  • [41] SUTURING TECHNIQUES IN PERIODONTAL SURGERY
    GALGUT, PN
    BRITISH DENTAL JOURNAL, 1989, 167 (01) : 29 - 31
  • [42] Suturing techniques in oral surgery
    C. Harte
    British Dental Journal, 2008, 205 (4) : 215 - 215
  • [43] SUTURING TECHNIQUES IN ENDOLARYNGEAL SURGERY
    KIRCHNER, FR
    LARYNGOSCOPE, 1981, 91 (11): : 1860 - 1864
  • [44] Tensile strength of surgical sutures and knotting techniques
    Fong, EDD
    Bartlett, A
    Malak, S
    Anderson, I
    BJU INTERNATIONAL, 2005, 95 : 27 - 28
  • [45] The Heilbronn laparoscopic training program for laparoscopic suturing: Concept and validation
    Teber, D
    Dekel, Y
    Frede, T
    Klein, J
    Rassweiler, J
    JOURNAL OF ENDOUROLOGY, 2005, 19 (02) : 230 - 238
  • [46] Application of spaghetti knotting technology in single-hole laparoscopic suturing instructional program on the basis of multi-directional stitching technology: a randomized controlled trial
    Chen, Ziqi
    Zhu, Sennan
    Tao, Jiayu
    Chen, Qiuyu
    Du, Wenzhuo
    Sun, Jindan
    Yu, Mengqi
    Zhou, Yi
    Zhao, Yu
    Zhang, Qiong
    BMC MEDICAL EDUCATION, 2024, 24 (01)
  • [47] Insertion Multi-Parachute Suturing and Knotting (IMS-K) Technique for Aortic Surgery
    Nakahara, Yoshinori
    Tateishi, Retsu
    Haba, Fumiya
    Ono, Syunya
    Kanemura, Takeyuki
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (02)
  • [48] Laparoscopic partial rephrectomy: renal defect closure without knotting
    Tong, R.
    Agarwal, D.
    Clarke, D.
    Grummet, J.
    BJU INTERNATIONAL, 2008, 101 : 35 - 35
  • [49] The impact of aptitude on the learning curve for laparoscopic suturing
    Buckley, Christina E.
    Kavanagh, Dara O.
    Nugent, Emmeline
    Ryan, Donncha
    Traynor, Oscar J.
    AMERICAN JOURNAL OF SURGERY, 2014, 207 (02): : 263 - 270
  • [50] Laparoscopic partial nephrectomy without intracorporeal suturing
    Li, Ching-Chia
    Yeh, Hsin-Chih
    Lee, Hsiang-Ying
    Li, Wei-Ming
    Ke, Hung-Lung
    Hsu, Allen Herng Shouh
    Lee, Mei Hui
    Tsai, Chia-Chun
    Chueh, Kuang-Shun
    Huang, Chun-Nung
    Chou, Yii-Her
    Li, Chien-Feng
    Wu, Wen-Jeng
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2016, 30 (04): : 1585 - 1591