Geometry of laparoscopic suturing and knotting techniques

被引:51
|
作者
Frede, T [1 ]
Stock, C [1 ]
Renner, C [1 ]
Budair, Z [1 ]
Abdel-Salam, Y [1 ]
Rassweiler, J [1 ]
机构
[1] Klinikum Heilbronn, Dept Urol, D-74078 Heilbronn, Germany
关键词
D O I
10.1089/end.1999.13.191
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background: Spatial limitation, together with a fixed trocar position, restricted handling, and movement of the instruments, is inevitably associated with reconstructive laparoscopy and retroperitoneoscopy. This problem includes not only suturing technique and instruments but also geometric factors of endoscopic reconstruction, such as optimal distances between the working trocars, length of instruments, and angles between the instruments and the object. We present an experimental access to determine the specific impact of these factors on reconstructive laparoscopy. Materials and Methods: In an in vitro model, end-to-end anastomoses of porcine intestine were performed using a standardized intracorporeal suturing technique. Suturing was performed without and after training in reconstructive surgery with variation of the following geometric factors: (1) the distance between the working trocars (between 6 and 12 cm); (2) the position of the object (lateral right, medially, lateral left); (3) the camera position (medially, lateral right, lateral left); (4) the angle between the instruments and a horizontal line (15 degrees, 55 degrees, 90 degrees); (5) the intracorporeal length of instruments (between 10 and 25 cm); and (6) narrowed space available for the instruments (between 4 and 25 cm). Results: Continual training decreased the time required for suturing between 30% to 50%. Training decreased the time required for nonsuturing activities between 50% and 70% but the time required for suturing activities only between 20% and 45%. If the space between instruments and camera was limited, shifting the camera into a lateral position simplified the procedure of intracorporeal suturing. Angles of <55 degrees between instruments and the horizontal line simplified laparoscopic suturing, as did angles of <45 degrees between the instruments. In cases of maximally narrowed space (diameter of 4 cm), a suture filament length of <10 cm decreased the time required by 30%. Conclusion: We suggest an isosceles triangle between the instruments with an angle between 25 degrees and 45 degrees and an angle of <55 degrees between the instruments and the horizontal line as the optimal geometry for intracorporeal suturing, These data should be considered when planning a reconstructive laparoscopic procedure (i.e., alignment of trocars, table position). However, further studies are required to confirm these preliminary results.
引用
收藏
页码:191 / 198
页数:8
相关论文
共 50 条
  • [21] Knot - free laparoscopic suturing
    Forbes, M.
    King, D.
    BJU INTERNATIONAL, 2010, 105 : 26 - 26
  • [22] A NEW CONCEPT OF LAPAROSCOPIC SUTURING
    AGARWAL, DK
    GAUR, DD
    AGARWAL, M
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 1994, 3 (04): : 227 - 229
  • [23] Improving laparoscopic suturing skills
    Anidjar, Maurice
    CUAJ-CANADIAN UROLOGICAL ASSOCIATION JOURNAL, 2009, 3 (01): : 31 - 31
  • [24] Knotting ligands to control metal coordination geometry
    Fabien B.L.Cougnon
    Science China(Chemistry), 2025, 68 (02) : 403 - 404
  • [25] Laparoscopic Suturing as a Barrier to Broader Adoption of Laparoscopic Surgery
    Lim, Sangtaeck
    Ghosh, Sudip
    Niklewski, Paul
    Roy, Sanjoy
    JSLS-JOURNAL OF THE SOCIETY OF LAPAROENDOSCOPIC SURGEONS, 2017, 21 (03)
  • [26] Quantification of process measures in laparoscopic suturing
    Dubrowski, A.
    Larmer, J. C.
    Leming, J. K.
    Brydges, R.
    Carnahan, H.
    Park, J.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2006, 20 (12): : 1862 - 1866
  • [27] Laparoscopic Suturing in 2 Easy Steps
    Singh, J. S.
    Nathan, K.
    AUSTRALIAN & NEW ZEALAND JOURNAL OF OBSTETRICS & GYNAECOLOGY, 2016, 56 : 58 - 59
  • [28] Ergonomic evaluation of laparoscopic bowel suturing
    Joice, P
    Hanna, GB
    Cuschieri, A
    AMERICAN JOURNAL OF SURGERY, 1998, 176 (04): : 373 - 378
  • [29] Suturing Techniques in Oral Implantology
    Springer, Ingo
    Wiltfang, Joerg
    Springer, Claudia
    IMPLANTOLOGIE, 2008, 16 (03): : 263 - 274
  • [30] NEW SUTURING DEVICE FOR LAPAROSCOPIC HYSTERECTOMY
    BADIA, CRD
    OBSTETRICS AND GYNECOLOGY, 1995, 85 (04): : 636 - 638