Geometry of laparoscopic suturing and knotting techniques

被引:51
|
作者
Frede, T [1 ]
Stock, C [1 ]
Renner, C [1 ]
Budair, Z [1 ]
Abdel-Salam, Y [1 ]
Rassweiler, J [1 ]
机构
[1] Klinikum Heilbronn, Dept Urol, D-74078 Heilbronn, Germany
关键词
D O I
10.1089/end.1999.13.191
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background: Spatial limitation, together with a fixed trocar position, restricted handling, and movement of the instruments, is inevitably associated with reconstructive laparoscopy and retroperitoneoscopy. This problem includes not only suturing technique and instruments but also geometric factors of endoscopic reconstruction, such as optimal distances between the working trocars, length of instruments, and angles between the instruments and the object. We present an experimental access to determine the specific impact of these factors on reconstructive laparoscopy. Materials and Methods: In an in vitro model, end-to-end anastomoses of porcine intestine were performed using a standardized intracorporeal suturing technique. Suturing was performed without and after training in reconstructive surgery with variation of the following geometric factors: (1) the distance between the working trocars (between 6 and 12 cm); (2) the position of the object (lateral right, medially, lateral left); (3) the camera position (medially, lateral right, lateral left); (4) the angle between the instruments and a horizontal line (15 degrees, 55 degrees, 90 degrees); (5) the intracorporeal length of instruments (between 10 and 25 cm); and (6) narrowed space available for the instruments (between 4 and 25 cm). Results: Continual training decreased the time required for suturing between 30% to 50%. Training decreased the time required for nonsuturing activities between 50% and 70% but the time required for suturing activities only between 20% and 45%. If the space between instruments and camera was limited, shifting the camera into a lateral position simplified the procedure of intracorporeal suturing. Angles of <55 degrees between instruments and the horizontal line simplified laparoscopic suturing, as did angles of <45 degrees between the instruments. In cases of maximally narrowed space (diameter of 4 cm), a suture filament length of <10 cm decreased the time required by 30%. Conclusion: We suggest an isosceles triangle between the instruments with an angle between 25 degrees and 45 degrees and an angle of <55 degrees between the instruments and the horizontal line as the optimal geometry for intracorporeal suturing, These data should be considered when planning a reconstructive laparoscopic procedure (i.e., alignment of trocars, table position). However, further studies are required to confirm these preliminary results.
引用
收藏
页码:191 / 198
页数:8
相关论文
共 50 条
  • [1] Suturing and knotting techniques for thoracoscopic cardiac surgery
    Szabo, Z
    Avery, J
    Sandor, A
    Litwin, DEM
    SURGICAL CLINICS OF NORTH AMERICA, 2000, 80 (05) : 1555 - +
  • [2] Learning microsurgical suturing and knotting techniques: Comparative data
    Furka, I
    Brath, E
    Nemeth, N
    Miko, I
    MICROSURGERY, 2006, 26 (01) : 4 - 7
  • [3] Laparoscopic Repair of Morgagni Hernia - Transfascial Suturing with Extracorporeal Knotting
    Graur, F.
    Mois, E.
    Al-Momani, N.
    Al-Hajjar, N.
    INTERNATIONAL CONFERENCE ON ADVANCEMENTS OF MEDICINE AND HEALTH CARE THROUGH TECHNOLOGY, MEDITECH 2016, 2017, 59 : 13 - 16
  • [4] Laparoscopic suturing and ligation techniques
    Pasic, R
    Levine, RL
    JOURNAL OF THE AMERICAN ASSOCIATION OF GYNECOLOGIC LAPAROSCOPISTS, 1995, 3 (01): : 67 - 79
  • [5] THERAPEUTIC LAPAROSCOPIC SUTURING TECHNIQUES
    KO, ST
    AIRAN, MC
    SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1992, 6 (01): : 41 - 46
  • [6] Integrating Laparoscopic Intracorporeal Suturing and Knot Tying into a Single Procedure Using a Novel Knotting Device
    Tu, Fung-Chao
    Sun, Hsu-Dong
    Chuang, Yi-Chen
    Wu, Wen-Yih
    Lin, Ho-Hsiung
    Hsiao, Sheng-Mou
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2015, 220 (01) : E1 - E5
  • [7] Laparoscopic suturing
    Hasson, HM
    JOURNAL OF THE AMERICAN ASSOCIATION OF GYNECOLOGIC LAPAROSCOPISTS, 2000, 7 (04): : 592 - 594
  • [8] Utilising spatial geometry to obtain the ideal needle mount for laparoscopic intracorporeal suturing
    Kanitkar, Rahul
    Muthukumarasamy, Girivasan
    Patil, Pradeep
    Tang, Benjie
    Zino, Samer
    BRITISH JOURNAL OF SURGERY, 2021, 108
  • [9] A comparison of novel laparoscopic suturing techniques in single-port surgery
    Terzi, Hasan
    Biler, Alper
    Turkay, Unal
    Kale, Ahmet
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2019, 28 (06) : 338 - 343
  • [10] A simple and efficient technique for suturing and knotting during endoscopic dacryocystorhinostomy
    Rongxin Chen
    Shu Liu
    Aixin Jiang
    Aizezi Wumaier
    Yuanxia Yang
    Xinyue Yu
    Ziwei Meng
    Yuxiang Mao
    Xuanwei Liang
    International Ophthalmology, 2023, 43 : 63 - 71