摘要
A flow-electrolytical cell containing a strand of micro Au modified carbon fiber electrodes (CFE) has been designedand characterized for use in a voltammatric detector for detecting cysteine using high-performance liquid chromatography. Cysteine is more efficiently electrochemical oxidized on a Au /CFE than a bare gold and carbon fiber electrode. The possible reaction mechanism of the oxidation process is described from the relations to scan rate, peak potentials and currents. For the pulse mode, and measurements with suitable experimental parameters, a linear concentration from 0.5 to 5.0 mg.L-1 was found. The limit of quantification for cysteine was below 60 ng.mL(-1).
引用
收藏
页码:3562 / 3577
页数:16
相关论文
共 29 条
  • [22] A new electrochemical sensor based on green synthesized CuO nanostructures modified carbon ionic liquid electrode for electrocatalytic oxidation and monitoring of L-cysteine
    Zaeifi, Fatemeh
    Sedaghati, Fatemeh
    Samari, Fayezeh
    MICROCHEMICAL JOURNAL, 2022, 183
  • [23] Development of Electrochemical Sensor Based on Glassy Carbon Electrode Modified with a Molecularly Imprinted Copolymer and its Application for Detection of Repaglinide
    Roushani, Mahmoud
    Jalilian, Zeynab
    ELECTROANALYSIS, 2018, 30 (11) : 2712 - 2718
  • [24] Electrochemical mechanism of eugenol at a Cu doped gold nanoparticles modified glassy carbon electrode and its analytical application in food samples
    Lin, Xiaoyun
    Ni, Yongnian
    Kokot, Serge
    ELECTROCHIMICA ACTA, 2014, 133 : 484 - 491
  • [25] A Voltammetric Sensor Based on Modified Multi-Walled Carbon Nanotubes for N-Acetyl-L-Cysteine Determination in the Presence of Tryptophan Using 4-Chlorocatechol as a Homogenous Electrochemical Catalyst
    Jahanshahi, Bita
    Raoof, Jahan Bakhsh
    Amiri-Aref, Mohaddeseh
    Ojani, Reza
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2015, 15 (05) : 3429 - 3436
  • [26] Electrochemical oxidation behavior of 2,4-dinitrophenol at hydroxylapatite film-modified glassy carbon electrode and its determination in water samples
    Yin, Huanshun
    Zhou, Yunlei
    Han, Ruixia
    Qiu, Yanyan
    Ai, Shiyun
    Zhu, Lusheng
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2012, 16 (01) : 75 - 82
  • [27] Electrochemical behavior of poly (naphthol green B)-film modified carbon paste electrode and its application for the determination of dopamine and uric acid
    Chitravathi, S.
    Swamy, B. E. Kumara
    Mamatha, G. P.
    Sherigara, B. S.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 667 : 66 - 75
  • [28] Electrochemical characteristics of cis-jasmone in acid media at multi-wall carbon nanotube-Nafion composite film modified electrode and its analytical application
    Dang, Xueping
    Hu, Chengguo
    Chen, Zilin
    Wang, Shengfu
    Hu, Shengshui
    ELECTROCHIMICA ACTA, 2012, 81 : 239 - 245
  • [29] Highly sensitive electrochemiluminescence determination of etamsylate using a low-cost electrochemical flow-through cell based on a tris (2, 2′-bipyridyl)ruthenium(II)-Nafion-modified carbon paste electrode
    Rao, Haiying
    Zhang, Jing
    Li, Jianguo
    LUMINESCENCE, 2014, 29 (07) : 784 - 790