Electrochemical Oxidation of Cysteine at a Film Gold Modified Carbon Fiber Microelectrode Its Application in a Flow-Through Voltammetric Sensor

被引:30
|
作者
Wang, Lai-Hao [1 ]
Huang, Wen-Shiuan [1 ]
机构
[1] Chia Nan Univ Pharm & Sci, Dept Med Chem, Tainan 71743, Taiwan
关键词
micro Au-modified carbon fiber electrode; pulse amperometric detection; cysteine; DUAL-ELECTRODE DETECTION; ACETYL-L-CYSTEINE; LIQUID-CHROMATOGRAPHY; AMINO-ACIDS; BIOSENSOR; SAMPLES; SYSTEM;
D O I
10.3390/s120303562
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow-electrolytical cell containing a strand of micro Au modified carbon fiber electrodes (CFE) has been designedand characterized for use in a voltammatric detector for detecting cysteine using high-performance liquid chromatography. Cysteine is more efficiently electrochemical oxidized on a Au /CFE than a bare gold and carbon fiber electrode. The possible reaction mechanism of the oxidation process is described from the relations to scan rate, peak potentials and currents. For the pulse mode, and measurements with suitable experimental parameters, a linear concentration from 0.5 to 5.0 mg.L-1 was found. The limit of quantification for cysteine was below 60 ng.mL(-1).
引用
收藏
页码:3562 / 3577
页数:16
相关论文
共 50 条
  • [1] Electrochemical Oxidation of L-selenomethionine and Se-methylseleno-L-cysteine at a Thiol-Compound-Modified Gold Electrode: Its Application in a Flow-Through Voltammetric Sensor
    Wang, Lai-Hao
    Zhang, Yu-Han
    SENSORS, 2017, 17 (02)
  • [2] The comparative electrochemistry of 2-mercaptothiazoline when using gold/quartz and modified silver/quartz electrodes, and its application in a flow-through voltammetric sensor
    Wang, Lai-Hao
    Chang, Yu-Hsuan
    ANALYTICAL METHODS, 2013, 5 (06) : 1407 - 1413
  • [3] Electrocatalytic oxidation and flow-through injection determination of cysteine with a glassy carbon electrode modified with gold-iridium binary system
    L. G. Shaidarova
    A. V. Gedmina
    I. A. Chelnokova
    G. K. Budnikov
    Russian Journal of Applied Chemistry, 2008, 81 : 988 - 993
  • [4] Electrocatalytic oxidation and flow-through injection determination of cysteine with a glassy carbon electrode modified with gold-iridium binary system
    Shaidarova, L. G.
    Gedmina, A. V.
    Chelnokova, I. A.
    Budnikov, G. K.
    RUSSIAN JOURNAL OF APPLIED CHEMISTRY, 2008, 81 (06) : 988 - 993
  • [5] Electrocatalytic oxidation and flow-through injection determination of cysteine with a glassy carbon electrode modified with gold-iridium binary system
    Kazan State University, Kazan, Tatarstan, Russia
    不详
    Russian Journal of Applied Chemistry, 2008, 81 (06): : 988 - 993
  • [6] Studies on the electrochemical behavior of the pilocarpine complex and its application using a flow-through polarographic sensor
    Wang, Lai-Hao
    Li, Yi-Hui
    CURRENT PHARMACEUTICAL ANALYSIS, 2008, 4 (01) : 33 - 38
  • [7] ELECTROCATALYTIC OXIDATION OF CARBOHYDRATES AT COPPER(II)-MODIFIED ELECTRODES AND ITS APPLICATION TO FLOW-THROUGH DETECTION
    KANO, K
    TORIMURA, M
    ESAKA, Y
    GOTO, M
    UEDA, T
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1994, 372 (1-2): : 137 - 143
  • [8] Electrochemical determination of butylhydroxyanisole (BHA) using a carbon fiber microelectrode modified by electrodeposition of gold nanoparticles and poly-NiTSPc film
    Bougna, Honorine Hortense Tchoumi
    Njanja, Evangeline
    Mbokou, Serge Foukmeniok
    Tagueu, Raissa Massah
    Bako, Yibor Fabrice Roland
    Pontie, Maxime
    Tonle, Ignas Kenfack
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2024, 54 (09) : 2121 - 2134
  • [9] Studies on the Electrochemical Behavior of Thiazolidine and Its Applications Using a Flow-Through Chronoamperometric Sensor Based on a Gold Electrode
    Wang, Lai-Hao
    Li, Wen-Jie
    MOLECULES, 2011, 16 (09) : 7608 - 7620
  • [10] Electrochemical oxidation and mechanism of sulfanilamide from groundwater in a flow-through system using carbon fiber (CF) anode
    Kim J.-G.
    Kim H.-B.
    Jeong W.-G.
    Lee K.-H.
    Baek K.
    Chemosphere, 2024, 349