Electrochemical Oxidation of Cysteine at a Film Gold Modified Carbon Fiber Microelectrode Its Application in a Flow-Through Voltammetric Sensor

被引:30
|
作者
Wang, Lai-Hao [1 ]
Huang, Wen-Shiuan [1 ]
机构
[1] Chia Nan Univ Pharm & Sci, Dept Med Chem, Tainan 71743, Taiwan
关键词
micro Au-modified carbon fiber electrode; pulse amperometric detection; cysteine; DUAL-ELECTRODE DETECTION; ACETYL-L-CYSTEINE; LIQUID-CHROMATOGRAPHY; AMINO-ACIDS; BIOSENSOR; SAMPLES; SYSTEM;
D O I
10.3390/s120303562
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow-electrolytical cell containing a strand of micro Au modified carbon fiber electrodes (CFE) has been designedand characterized for use in a voltammatric detector for detecting cysteine using high-performance liquid chromatography. Cysteine is more efficiently electrochemical oxidized on a Au /CFE than a bare gold and carbon fiber electrode. The possible reaction mechanism of the oxidation process is described from the relations to scan rate, peak potentials and currents. For the pulse mode, and measurements with suitable experimental parameters, a linear concentration from 0.5 to 5.0 mg.L-1 was found. The limit of quantification for cysteine was below 60 ng.mL(-1).
引用
收藏
页码:3562 / 3577
页数:16
相关论文
共 29 条
  • [1] Electrocatalytic oxidation and flow-through injection determination of cysteine with a glassy carbon electrode modified with gold-iridium binary system
    L. G. Shaidarova
    A. V. Gedmina
    I. A. Chelnokova
    G. K. Budnikov
    Russian Journal of Applied Chemistry, 2008, 81 : 988 - 993
  • [2] A Flow-through Electrochemical Sensor with Renewable Copper Modified Electrode for Sensitive Nitrate Detection
    Li, Yang
    Song, Yu
    Bai, Yin
    Sun, Jizhou
    Bian, Chao
    Tong, Jianhua
    Xia, Shanhong
    2016 IEEE 11TH ANNUAL INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS (NEMS), 2016,
  • [3] Electrocatalytic oxidation of tyrosine at poly(threonine)-film modified carbon paste electrode and its voltammetric determination in real samples
    Chitravathi, S.
    Swamy, B. E. Kumara
    Mamatha, G. P.
    Chandrashekar, B. N.
    JOURNAL OF MOLECULAR LIQUIDS, 2012, 172 : 130 - 135
  • [4] Communication-Electrochemical Impedance Signature of a Non-Planar, Interdigitated, Flow-Through, Porous, Carbon-Based Microelectrode
    Li, Zhenglong
    Cheng, Yu-Hsuan
    Feng, Lixin
    Felix, De Dios
    Neil, Jacob
    Antonio, Reis Moura Pedro
    Rahman, Maryom
    Yang, Juliana
    Azizighannad, Samar
    Mitra, Somenath
    Basuray, Sagnik
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (16) : B1669 - B1672
  • [5] Electrochemical Behavior of Oxytocin Hormone through its Cysteine Reduction Peak Using Glassy Carbon Electrode Modified with PolyFurfurylamine and Multi-Walled Carbon Nanotubes
    Al-Taee, Amer Th.
    Al-Hyali, Rana H.
    EGYPTIAN JOURNAL OF CHEMISTRY, 2021, 64 (10): : 5831 - 5837
  • [6] Construction of Electrochemical Sensor Based on Praseodymium Hexacyanoferrate Modified Graphite Electrode and Its Application for Cysteine Determination
    Zhong Yuan-Wen
    Lin Mou-Hong
    Zhou Jie-Dan
    Liu Ying-Ju
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (02) : 229 - 232
  • [7] Fabrication of functionalized carbon nanotube modified glassy carbon electrode and its application for selective oxidation and voltammetric determination of cysteamine
    Raoof, Jahan Bakhsh
    Ojani, Reza
    Chekin, Fereshteh
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2009, 633 (01) : 187 - 192
  • [8] Construction of an Electrochemical Cell System Based on Carbon Composite Film Electrodes and its Application for Voltammetric Determination of Triclosan
    Libansky, Milan
    Zima, Jiri
    Barek, Jiri
    Dejmkova, Hana
    ELECTROANALYSIS, 2014, 26 (09) : 1920 - 1927
  • [9] A sensitive hydrazine electrochemical sensor based on electrodeposition of gold nanoparticles on choline film modified glassy carbon electrode
    Li, Jing
    Xie, Huaqing
    Chen, Lifei
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 153 (01) : 239 - 245
  • [10] Studies on the Electrochemical Behavior of Eugenol and its Application Using a Flow - Through Chronoamperometric Sensor
    Wang, Lai-Hao
    Chen, Jhih-Cheng
    CURRENT PHARMACEUTICAL ANALYSIS, 2011, 7 (02) : 88 - 94