Exploring the Possibilities of Cryogenic Cooling in Liquid Chromatography for Biological Applications: A Proof of Principle

被引:28
作者
Eghbali, Hamed [1 ]
Sandra, Koen [2 ]
Tienpont, Bart [2 ]
Eeltink, Sebastiaan [1 ]
Sandra, Pat [2 ]
Desmet, Gert [1 ]
机构
[1] Vrije Univ Brussel, Dept Chem Engn, B-1050 Brussels, Belgium
[2] Res Inst Chromatog, B-8500 Kortrijk, Belgium
关键词
GAS-CHROMATOGRAPHY; SUPERHEATED WATER; TEMPERATURE; ELUENT;
D O I
10.1021/ac203252u
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The possibilities to use cryogenic cooling to trap components in liquid chromatography was investigated. In a first step, van 't Hoff plots were measured with a reversed-phase column using the temperature control unit of a conventional high performance liquid chromatography (HPLC) system to gain insight in the retention behavior of proteins at low temperatures. It was estimated that retention factors in the range of k = 10(4) could be achieved at T = -20 degrees C for lysozyme, indicating that temperature is a usable parameter to trap components in LC. In a next step, trapping experiments were carried out on a nano-LC system, equipped with a UV-detector, using a commercial reversed-phase column. An in-house built setup, allowing cooling of a segment of the column, down to temperatures below T = -20 degrees C, was used to trap components. Experiments were conducted under isocratic and gradient conditions with methanol as organic solvent. It is demonstrated that, by thermally trapping and elution of components, an enhanced S/N ratio and decreased peak widths can be obtained. At the same time, a significant increase in pressure drop occurs during the cooling process. Limitations and benefits of the technique are further discussed.
引用
收藏
页码:2031 / 2037
页数:7
相关论文
共 27 条
  • [1] HIGH-SPEED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PEPTIDES AND PROTEINS
    CHEN, H
    HORVATH, C
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1995, 705 (01) : 3 - 20
  • [2] Chen MH, 1997, J CHROMATOGR A, V788, P51
  • [3] Miniaturization and automation of an internally cooled coated fiber device
    Chen, Yong
    Pawliszyn, Janusz
    [J]. ANALYTICAL CHEMISTRY, 2006, 78 (14) : 5222 - 5226
  • [4] Versatile Capillary Column Temperature Control Using a Thermoelectric Array Based Platform
    Collins, David
    Nesterenko, Ekaterina
    Connolly, Damian
    Vasquez, Mercedes
    Macka, Mirek
    Brabazon, Dermot
    Paull, Brett
    [J]. ANALYTICAL CHEMISTRY, 2011, 83 (11) : 4307 - 4313
  • [5] USE OF HEART CUTTING IN GAS-CHROMATOGRAPHY - A REVIEW
    DEANS, DR
    [J]. JOURNAL OF CHROMATOGRAPHY, 1981, 203 (JAN): : 19 - 28
  • [6] Greibrokk T, 2001, J SEP SCI, V24, P899, DOI 10.1002/1615-9314(20011201)24:12<899::AID-JSSC899>3.3.CO
  • [7] 2-B
  • [8] Effect of temperature in reversed phase liquid chromatography
    Guillarme, D
    Heinisch, S
    Rocca, JL
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2004, 1052 (1-2) : 39 - 51
  • [9] Recent developments in liquid chromatography - Impact on qualitative and quantitative performance
    Guillarme, Davy
    Nguyen, Dao T. -T.
    Rudaz, Serge
    Veuthey, Jean-Luc
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1149 (01) : 20 - 29
  • [10] New liquid nitrogen cryogenic modulator for comprehensive two-dimensional gas chromatography
    Harynuk, J
    Górecki, T
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2003, 1019 (1-2) : 53 - 63