The calorimetric measurement of losses in HTS tapes due to ac magnetic fields and transport currents
被引:62
作者:
Ashworth, SP
论文数: 0引用数: 0
h-index: 0
机构:
Brookhaven Natl Lab, Div Mat Sci, Upton, NY 11973 USABrookhaven Natl Lab, Div Mat Sci, Upton, NY 11973 USA
Ashworth, SP
[1
]
Suenaga, M
论文数: 0引用数: 0
h-index: 0
机构:
Brookhaven Natl Lab, Div Mat Sci, Upton, NY 11973 USABrookhaven Natl Lab, Div Mat Sci, Upton, NY 11973 USA
Suenaga, M
[1
]
机构:
[1] Brookhaven Natl Lab, Div Mat Sci, Upton, NY 11973 USA
来源:
PHYSICA C
|
1999年
/
315卷
/
1-2期
关键词:
calorimetric measurement;
HTS tapes;
magnetic fields;
transport currents;
D O I:
10.1016/S0921-4534(99)00216-6
中图分类号:
O59 [应用物理学];
学科分类号:
摘要:
We report a simple technique for the measurement of energy losses in HTS tape carrying ac currents in ac magnetic fields at liquid nitrogen temperatures. This method is based on measuring the temperature rise of a thermally insulated tape and in the present form is able to measure losses down to 0.01 W m(-1). We present data obtained by this method confirming previously published results for the losses at 100 Hz due to in phase ac currents and magnetic fields as measured electrically. Using this calorimetric method we are able to measure the effect of phase differences between current and field. (C) 1999 Published by Elsevier Science B.V. All rights reserved.