The calorimetric measurement of losses in HTS tapes due to ac magnetic fields and transport currents

被引:62
作者
Ashworth, SP [1 ]
Suenaga, M [1 ]
机构
[1] Brookhaven Natl Lab, Div Mat Sci, Upton, NY 11973 USA
来源
PHYSICA C | 1999年 / 315卷 / 1-2期
关键词
calorimetric measurement; HTS tapes; magnetic fields; transport currents;
D O I
10.1016/S0921-4534(99)00216-6
中图分类号
O59 [应用物理学];
学科分类号
摘要
We report a simple technique for the measurement of energy losses in HTS tape carrying ac currents in ac magnetic fields at liquid nitrogen temperatures. This method is based on measuring the temperature rise of a thermally insulated tape and in the present form is able to measure losses down to 0.01 W m(-1). We present data obtained by this method confirming previously published results for the losses at 100 Hz due to in phase ac currents and magnetic fields as measured electrically. Using this calorimetric method we are able to measure the effect of phase differences between current and field. (C) 1999 Published by Elsevier Science B.V. All rights reserved.
引用
收藏
页码:79 / 84
页数:6
相关论文
共 4 条
  • [1] Measurement of ac losses in superconductors due to ac transport currents in applied ac magnetic fields
    Ashworth, SP
    Suenaga, M
    [J]. PHYSICA C, 1999, 313 (3-4): : 175 - 187
  • [2] ASHWORTH SP, UNPUB IEEE T APPL SU
  • [3] CHAKRABORTY N, UNPUB IEEE T APPL SU, V8
  • [4] Improvements and validation of the null calorimetric method for a.c. loss measurements in superconductors
    Dolez, P
    Cave, J
    Willen, D
    Zhu, W
    Aubin, M
    [J]. CRYOGENICS, 1998, 38 (04) : 429 - 434