Safety and Efficacy of a New Water Gradient Biomimetic Monthly Replacement Spherical Contact Lens Material (Lehfilcon A)

被引:6
作者
Wesley, Gina [1 ]
Giedd, Brad [2 ]
Hines, Bradley [3 ]
Bickle, Katherine [4 ]
Pearson, Christopher [5 ]
Lorentz, Holly [6 ,7 ]
机构
[1] Complete Eye Care Medina, Hamel, MN USA
[2] Kindred Opt Maitland Vis, Maitland, FL USA
[3] Optometry Grp, Memphis, TN USA
[4] ProCare Vis Ctr, Granville, OH USA
[5] OMEGA Vis Ctr PA, Longwood, FL USA
[6] Alcon Res LLC, Johns Creek, GA USA
[7] Alcon Res LLC, 11460 Johns Creek Pkwy, Johns Creek, GA 30097 USA
来源
CLINICAL OPHTHALMOLOGY | 2022年 / 16卷
关键词
biomimetic; comfilcon A; lehfilcon A; visual acuity; water gradient; contact lens; OCULAR SURFACE; SILICONE HYDROGELS; WEAR; EYE;
D O I
10.2147/OPTH.S362926
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The objective of this study was to evaluate the safety and performance of the investigational lens, lehfilcon A, when worn in a daily wear modality and replaced monthly as compared to the commercially available comfilcon A contact lens.Methods: This was a multicenter, prospective, controlled, double-masked, randomized, parallel-group clinical study with bilateral lens wear for 3 months. In all, 115 subjects completed the study (77 with test lehfilcon A and 38 with control comfilcon A contact lenses). Distance visual acuity (VA) was assessed using Snellen VA. Lens performance was assessed by examining lens fit/movement, centration, front surface wettability and front/back surface deposits using slit-lamp biomicroscopy.Results: At the 3-month follow-up visit, all eyes had a distance VA of 20/20 or better. Further, lens fit/movement was assessed as optimal in 92.9% of the eyes with lehfilcon A and 89.2% with comfilcon A. There were no ratings of unacceptably tight or loose fits for either contact lens material. Lens centration was assessed as optimal in 98.7% of eyes with lehfilcon A and 94.6% with comfilcon A. For front and back surface deposits, both materials showed minimal lens surface deposits. Front surface wettability was assessed as grade 0 or 1 for most of the study lenses in both lens groups across all attended study visits. There were no ocular adverse events related to the study lenses.Conclusion: Overall, lehfilcon A showed excellent VA, optimal lens fitting characteristics, a clean surface, high wettability, and low risk for adverse events after 3 months of lens wear.
引用
收藏
页码:2873 / 2884
页数:12
相关论文
共 47 条
  • [1] Polyzwitterionic brushes: Extreme lubrication by design
    Chen, Meng
    Briscoe, Wuge H.
    Armes, Steven P.
    Cohen, Hagai
    Klein, Jacob
    [J]. EUROPEAN POLYMER JOURNAL, 2011, 47 (04) : 511 - 523
  • [2] Characterization of Soft Contact Lens Fitting Using Ultra-Long Scan Depth Optical Coherence Tomography
    Cui, Lele
    Li, Ming
    Shen, Meixiao
    Lu, Fan
    Wang, Jianhua
    [J]. JOURNAL OF OPHTHALMOLOGY, 2017, 2017
  • [3] Dalton A, 2021, BRIT CONTACT LENS AS
  • [4] The relationship between compliance with lens replacement and contact lens-related problems in silicone hydrogel wearers
    Dumbleton, Kathryn A.
    Woods, Craig A.
    Jones, Lyndon W.
    Fonn, Desmond
    [J]. CONTACT LENS & ANTERIOR EYE, 2011, 34 (05) : 216 - 222
  • [5] Compliance with Lens Replacement and the Interval between Eye Examinations
    Dumbleton, Kathy
    Richter, Doris
    Bergenske, Peter
    Jones, Lyndon W.
    [J]. OPTOMETRY AND VISION SCIENCE, 2013, 90 (04) : 351 - 358
  • [6] The Impact of Contemporary Contact Lenses on Contact Lens Discontinuation
    Dumbleton, Kathy
    Woods, Craig A.
    Jones, Lyndon W.
    Fonn, Desmond
    [J]. EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2013, 39 (01): : 93 - 99
  • [7] Contact lens-induced changes in the anterior eye as observed in vivo with the confocal microscope
    Efron, Nathan
    [J]. PROGRESS IN RETINAL AND EYE RESEARCH, 2007, 26 (04) : 398 - 436
  • [8] Comfort-Enhanced Daily Disposable Contact Lens Reduces Symptoms Among Weekly/Monthly Wear Patients
    Fahmy, Mary
    Long, Bill
    Giles, Timothy
    Wang, Chiao-Hua
    [J]. EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2010, 36 (04): : 215 - 219
  • [9] The ocular surface: The challenge to enable and protect vision: The Friedenwald lecture
    Gipson, Ilene K.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (10) : 4391 - 4398
  • [10] Soft contact lens biomaterials from bioinspired phospholipid polymers
    Goda, Tatsuro
    Ishihara, Kozuhiko
    [J]. EXPERT REVIEW OF MEDICAL DEVICES, 2006, 3 (02) : 167 - 174