CT-fluoroscopy: Tool or gimmick?

被引:26
作者
Froelich, JJ [1 ]
Wagner, HJ [1 ]
机构
[1] Univ Marburg, Hosp, Dept Radiol, D-35043 Marburg, Germany
关键词
computed tomography (CT); guidance; interventional procedures; technology; computed tomography; radiation exposure; fluoroscopy;
D O I
10.1007/s00270-001-0042-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Recent advances in CT scanner technology and computer hardware have led to the development of CT fluoroscopy (CTF), which allows real-time acquisition and display of cross-sectional images (with a rate of up to 8 frames per second). Since the introduction of the first CT fluoroscopy scanner in 1993, a variety of these scanners have been installed world-wide and many reports on the clinical use of this device have appeared recently. However, use of this new technology for the guidance of interventional radiologic procedures, such as percutaneous biopsy and percutaneous drainage, is not uniformly advocated by interventional. radiologists. Concerns have been reported regarding radiation exposure and outcome of the procedures when compared with sequential CT guidance or other alternative guiding modalities. This article is intended to present an overview of CTF technology, to summarize the results of published papers on various interventional applications and to reflect on its specific advantages and disadvantages.
引用
收藏
页码:297 / 305
页数:9
相关论文
共 35 条
  • [1] CLINICAL-ASSESSMENT OF AN INTERVENTIONAL CT TABLE
    COSTELLO, P
    GAA, J
    [J]. RADIOLOGY, 1993, 189 (01) : 284 - 285
  • [2] Percutaneous abdominal and pelvic interventional procedures using CT fluoroscopy guidance
    Daly, B
    Krebs, TL
    Wong-You-Cheong, JJ
    Wang, SS
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (03) : 637 - 644
  • [3] Real-time CT fluoroscopy: Evolution of an interventional tool
    Daly, B
    Templeton, PA
    [J]. RADIOLOGY, 1999, 211 (02) : 309 - 315
  • [4] Daly B, 1997, AJR S, V168, P143
  • [5] CT-FLUOROSCOPY LINK-UP (CTF) - POTENTIAL FOR SPECIAL PROCEDURES
    DAMASCELLI, B
    PORCELLI, G
    SPREAFICO, C
    MARCHIANO, A
    MILELLA, M
    GARBAGNATI, F
    FRIGERIO, LF
    SALVETTI, M
    BONALUMI, MG
    COZZI, G
    MAURI, M
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 1990, 11 (02) : 81 - 86
  • [6] Real time CT-fluoroscopy: diagnostic and therapeutic applications
    de Mey, J
    Op de Beeck, B
    Meysman, M
    Noppen, M
    De Maeseneer, M
    Vanhoey, M
    Vincken, W
    Osteaux, M
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2000, 34 (01) : 32 - 40
  • [7] Froelich JJ, 1999, ROFO-FORTSCHR RONTG, V170, P191
  • [8] Comparison of C-arm CT fluoroscopy and conventional fluoroscopy for percutaneous biliary drainage procedures
    Froelich, JJ
    Wagner, HJ
    Ishaque, N
    Alfke, H
    Scherf, C
    Klose, KJ
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2000, 11 (04) : 477 - 482
  • [9] Real-time CT-fluoroscopy for guidance of percutaneous drainage procedures
    Froelich, JJ
    Saar, B
    Hoppe, M
    Ishaque, N
    Walthers, EM
    Regn, J
    Klose, KJ
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 9 (05) : 735 - 740
  • [10] FROELICH JJ, 2001, IN PRESS EUR J RADIO