Electromicrofluidic device with integrated PDMS microchannel and laser-induced graphene electrodes for electrochemical detection of cardiac biomarker in a point-of-care platform

被引:8
|
作者
Dudala, Sohan [1 ,2 ]
Dubey, Satish Kumar [1 ,3 ]
Javed, Arshad [1 ,3 ]
Ganguly, Anasuya [4 ]
Goel, Sanket [1 ,2 ]
机构
[1] Birla Inst Technol & Sci Pilani, Microfluid & Nanoelect Lab, MEMS, Hyderabad Campus, Hyderabad 500078, Telangana, India
[2] Birla Inst Technol & Sci Pilani, Dept Elect & Elect Engn, Hyderabad Campus, Hyderabad 500078, Telangana, India
[3] Birla Inst Technol & Sci Pilani, Dept Mech Engn, Hyderabad Campus, Hyderabad 500078, Telangana, India
[4] BITS Pilani, Dept Biol Sci, KK Birla Goa Campus, Sancoale 403726, Goa, India
关键词
laser-induced graphene; microfluidics; cardiac biomarkers; MYOCARDIAL-INFARCTION; MICROFLUIDIC SYSTEM; EARLY-DIAGNOSIS; SUBSTRATE; SENSOR; PUMPS;
D O I
10.1088/1361-6439/ac8a55
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
By providing a facile and scalable alternative to otherwise complex and resource-intensive synthesis of graphene, laser-induced graphene (LIG) is spearheading the translation of graphene-based propositions to deployable technologies for societal benefit. LIG is a versatile and economical synthesis approach which is being used on a variety of substrates and in a multitude of applications-including miniaturized sensing systems. One aspect that has not been addressed thoroughly in LIG-based miniaturized sensing systems is its successful integration with microfluidics and its possible use in point-of-care settings. To further diversify the applications of LIG with integrated microfluidics, this work reports on the development of an integrated flexible microfluidics-LIG based electrochemical biosensor. The work describes the methodology to develop a polydimethylsiloxane-LIG scribed polyamide microfluidic device in a leakage-free flexible application. In view of the excellent electrical and electrochemical properties of LIG, such device has been employed for electrochemical biosensing. The biosensing capabilities of the microfluidic device were validated via sensing of cardiac troponin I-a gold standard cardiac biomarker for early identification of acute myocardial infarction (AMI). The developed biosensor demonstrated a detection and quantification limit of 45.33 pg ml(-1) and 151.10 pg ml(-1) respectively, which are in clinically significant ranges for diagnosis of AMI. The mu-fluidic biosensor was also analyzed for stability and interference with other cardiac biomarkers. The developed integrated mu-fluidic electrochemical biosensor was evaluated for possible point-of-source applications in conjunction with a custom 3D printed peristaltic pump and smartphone-enabled miniaturized potentiostat.
引用
收藏
页数:11
相关论文
共 29 条
  • [1] Laser-induced fluorescence detection platform for point-of-care testing
    Berner, Marcel
    Hilbig, Urs
    Schubert, Markus B.
    Gauglitz, Guenter
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2017, 28 (08)
  • [2] TOWARDS A FULLY INTEGRATED LASER-INDUCED FLUORESCENCE DETECTION DEVICE FOR POINT-OF-CARE BIOANALYSIS
    Kamei, T.
    Ito, S.
    Kobayashi, T.
    Maeda, R.
    2012 IEEE 25TH INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS), 2012,
  • [3] Microfluidic Device Integrated With PDMS Microchannel and Unmodified ITO Glass Electrodes for Highly Sensitive, Specific, and Point-of-Care Detection of Copper and Mercury
    Mohan, Jaligam Murali
    Dudala, Sohan
    Amreen, Khairunnisa
    Javed, Arshad
    Dubey, Satish Kumar
    Goel, Sanket
    IEEE TRANSACTIONS ON NANOBIOSCIENCE, 2023, 22 (04) : 881 - 888
  • [4] Laser-induced fibers and copper phthalocyanine modified laser-induced graphene electrodes for sensitive and selective electrochemical detection of nitrite
    Adiraju, Anurag
    Jalasutram, Aditya
    Al-Hamry, Ammar
    Talbi, Malak
    Wang, Junfei
    Tegenkamp, Christoph
    Kanoun, Olfa
    RSC ADVANCES, 2024, 14 (39) : 28648 - 28658
  • [5] Laser-induced fluorescence detection modules for point-of-care microfluidic biochemical analysis
    Kamei, Toshihiro
    EUROSENSORS XXV, 2011, 25
  • [6] A flexible multiplexed electrochemical biosensing platform with graphene and gold nanoparticle modification for enhanced e-ELISA point-of-care biomarker detection
    Hosseini, Zahrasadat
    Shi, Dongmin
    Yuan, Jie
    MICROCHEMICAL JOURNAL, 2025, 208
  • [7] Construction of a new versatile point-of-care testing device with electrochemical detection employing paper as a microfluidic platform
    Silva, E. T. S. G.
    Santhiago, M.
    Barragan, J. T. C.
    Kubota, L. T.
    ANALYTICAL METHODS, 2014, 6 (15) : 6133 - 6136
  • [8] Hybrid Paper/Polyester-Based Laser-Induced Graphene Electrodes for Electrochemical Detection of Tadalafil
    Souza, Shellyda G. G.
    Silva-Neto, Habdias A.
    Rocha, Danielly S.
    de Siervo, Abner
    Paixao, Thiago R. L. C.
    Coltro, Wendell K. T.
    ANALYSIS & SENSING, 2024, 4 (06):
  • [9] A sensitive electrochemical platform integrated with a 3D graphene aerogel for point-of-care testing for tumor markers
    Hu, Tao
    Wu, Zihao
    Sang, Wen
    Ding, Bo
    Chen, Ke
    Li, Xiao
    Shen, Yang
    Ni, Zhonghua
    JOURNAL OF MATERIALS CHEMISTRY B, 2022, 10 (36) : 6928 - 6938
  • [10] Disposable Miniaturized Electrochemical Sensing Platform With Laser-Induced Reduced Graphene Oxide Electrodes for Multiplexed Biochemical Analysis
    Singh, Ritesh Kumar
    Kumar, Pavar Sai
    Amreen, Khairunnisa
    Dubey, Satish Kumar
    Goel, Sanket
    IEEE TRANSACTIONS ON NANOBIOSCIENCE, 2023, 22 (03) : 548 - 553