Hyperpolarized 3He gas production and MR imaging of the lung

被引:78
作者
Leawoods, JC [1 ]
Yablonskiy, DA
Saam, B
Gierada, DS
Conradi, MS
机构
[1] Washington Univ, Dept Phys, St Louis, MO 63130 USA
[2] Washington Univ, Dept Radiol 8131, St Louis, MO 63130 USA
[3] Univ Utah, Dept Phys, Salt Lake City, UT 84112 USA
来源
CONCEPTS IN MAGNETIC RESONANCE | 2001年 / 13卷 / 05期
关键词
hyperpolarized; NMR; MRI;
D O I
10.1002/cmr.1014
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
optical polarization of He-3 generates large nuclear spin magnetizations, allowing MR imaging of the gas spaces of human and animal lungs despite the low number density of spins in the gas. The atomic physics of optical pumping and spin exchange is explained; the hardware for polarizing, transporting, and imaging is detailed. Pulse sequences for optimum use of the nonrenewable magnetization require a different imaging strategy than traditional proton MRI. Examples are discussed for static lung images, diffusion images for characterization of the local alveolar structure, and high temporal resolution images. (C) 2001 John Wiley & Sons, Inc.
引用
收藏
页码:277 / 293
页数:17
相关论文
共 50 条
[21]   Measurement of Gas Transport Kinetics in High-Frequency Oscillatory Ventilation (HFOV) of the Lung Using Hyperpolarized 3He Magnetic Resonance Imaging [J].
Terekhov, Maxim ;
Rivoire, Julien ;
Scholz, Alexander ;
Wolf, Ursula ;
Karpuk, Sergei ;
Salhi, Zahir ;
Koebrich, Rainer ;
David, Matthias ;
Schreiber, Laura Maria .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 32 (04) :887-894
[22]   Two and Three-Dimensional Segmentation of Hyperpolarized 3He Magnetic Resonance Imaging of Pulmonary Gas Distribution [J].
Heydarian, Mohammadreza ;
Kirby, Miranda ;
Wheatley, Andrew ;
Fenster, Aaron ;
Parraga, Grace .
MEDICAL IMAGING 2012: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2012, 8317
[23]   Quantitative assessment of emphysema using hyperpolarized 3He magnetic resonance imaging [J].
Spector, ZZ ;
Emami, K ;
Fischer, MC ;
Zhu, J ;
Ishii, M ;
Vahdat, V ;
Yu, J ;
Kadlecek, S ;
Driehuys, B ;
Lipson, DA ;
Gefter, W ;
Shrager, J ;
Rizi, RR .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (06) :1341-1346
[24]   Hyperpolarized Gas MR Imaging of the Lung: Current Status as a Research Tool [J].
Matsuoka, Shin ;
Patz, Samuel ;
Albert, Mitchell S. ;
Sun, Yanping ;
Rizi, Rahim R. ;
Gefter, Warren B. ;
Hatabu, Hiroto .
JOURNAL OF THORACIC IMAGING, 2009, 24 (03) :181-188
[25]   MRI of the lung using hyperpolarized 3He at very low magnetic field (3 mT) [J].
C.P. Bidinosti ;
J. Choukeife ;
G. Tastevin ;
P.-J. Nacher ;
A. Vignaud .
Magnetic Resonance Materials in Physics, Biology and Medicine, 2004, 16 :255-258
[26]   MRI of the lung using hyperpolarized 3He at very low magnetic field (3 mT) [J].
Bidinosti, CP ;
Choukeife, J ;
Tastevin, G ;
Vignaud, A ;
Nacher, PJ .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2004, 16 (06) :255-258
[27]   Gas cells for 3He hyperpolarized via spin-exchange optical pumping [J].
W. Kim ;
S. S. Stepanyan ;
A. Kim ;
J. A. Tan ;
S. Woo .
Journal of the Korean Physical Society, 2016, 68 :183-189
[28]   Comparison of hyperpolarized 3He MRI with Xe-enhanced computed tomography imaging for ventilation mapping of rat lung [J].
Santyr, Giles E. ;
Couch, Marcus J. ;
Lam, Wilfred W. ;
Ouriadov, Alexei ;
Drangova, Maria ;
McCormack, David G. ;
Holdsworth, David W. .
NMR IN BIOMEDICINE, 2011, 24 (09) :1073-1080
[29]   Hyperpolarized 3He pulmonary functional magnetic resonance imaging prior to radiation therapy [J].
Mathew, Lindsay ;
VanDyk, Jake ;
Etemad-Rezai, Roya ;
Rodrigues, George ;
Parraga, Grace .
MEDICAL PHYSICS, 2012, 39 (07) :4284-4290
[30]   Flip-Angle Measurement by Magnetization Inversion: Calibration of Magnetization Nutation Angle in Hyperpolarized 3He Magnetic Resonance Imaging Lung Experiments [J].
Rivoire, J. ;
Terekhov, M. ;
Meise, F. M. ;
Gast, K. ;
Salhi, Z. ;
Schreiber, L. M. .
MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (02) :399-408