Rapid Determination of REEs, PGEs, and Other Trace Elements in Geological and Environmental Materials by High Resolution Inductively Coupled Plasma Mass Spectrometry

被引:136
|
作者
Satyanarayanan, M. [1 ]
Balaram, V [1 ]
Sawant, S. S. [1 ]
Subramanyam, K. S., V [1 ]
Krishna, G. Vamsi [1 ]
Dasaram, B. [1 ]
Manikyamba, C. [1 ]
机构
[1] Natl Geophys Res Inst, CSIR, Hyderabad 500007, Andhra Prades, India
关键词
PLATINUM-GROUP ELEMENTS; SECTOR ICP-MS; PRECIOUS METALS; INDIAN-OCEAN; GROUNDWATER; HYDERABAD; SINGLE; AES;
D O I
10.46770/AS.2018.01.001
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Methodologies were designed and developed using magnetic sector high resolution inductively coupled plasma mass spectrometry (IIR-ICP-MS) for the fast, reliable, and accurate determination of different sets of geochemically significant trace elements (at sub-ng/g to pg/g levels) including rare earth elements (REEs) and platinum group elements (PGEs) in a variety of geological materials for their application in advanced geochemical studies. In the case of trace elements (including REE) in rock, mineral, soil, and sediment samples, about 50 mg each of the samples was dissolved in Savillex (R) pressure decomposition vessels by utilizing a mix of hydrolluoric-intricperchloric adds. Procedural blanks were prepared in a similar way. Trace elements were determined in water samples directly after filtration, acidification, and appropriate dilution with Xe-129 and Xe-132 as the internal standards. NiS fire assay and Te co-precipitation methods were used for the separation and pre-concentration of the PGEs and Au from the rock matrix (similar to 10 g properly homogenized samples) before their determination by HR-ICP-MS. Synthetic multi-element solutions (1, 10, and 100 ng/mL) were used for the preparation of calibration graphs. In order to validate these methods, a series of international geo-standards starting from acidic to ultra-basic rock, soil, sediment, stream sediment, and water reference samples were analyzed after optimizing the instrumental parameters. Most spectroscopic interferences were removed by choosing optimum resolution (300R) settings for each element or group of elements for the separation of the interfering peaks, such as doubly charged ions and polyatomic species, from the analyze peaks of interest. The matrix effects were minimized by analyzing very diluted samples. Extremely close agreement was found between the data sets by IIR-ICP-MS with certified values wherever data available for comparison. The precisions obtained in this study were <2% RSD for the majority of elements with comparable accuracy, confirming that the methodologies designed and developed in this study are suitable for obtaining precise data suitable for high precision geochemical, mineral exploration, and environmental studies.
引用
收藏
页码:1 / 15
页数:15
相关论文
共 50 条
  • [41] On the determination of platinum group elements in environmental materials by inductively coupled plasma mass spectrometry and microwave digestion
    Djingova, R
    Heidenreich, H
    Kovacheva, P
    Markert, B
    ANALYTICA CHIMICA ACTA, 2003, 489 (02) : 245 - 251
  • [42] Rapid determination of trace elements in serum of hepatocellular carcinoma patients by inductively coupled plasma tandem mass spectrometry
    Fu, Liang
    Xie, Hualin
    Huang, Jianhua
    Chen, Lin
    ANALYTICA CHIMICA ACTA, 2020, 1112 : 1 - 7
  • [43] Determination of Trace Elements in High Purity Gold by Laser Ablation Inductively Coupled Plasma Mass Spectrometry
    Chen X.
    Hu F.
    Zang M.
    Sun Z.
    Liu Y.
    Tong J.
    Xiyou Jinshu/Chinese Journal of Rare Metals, 2021, 45 (03): : 333 - 340
  • [44] Determination of trace elements in sea weed samples by inductively coupled plasma mass spectrometry
    Sakao, S
    Ogawa, Y
    Uchida, H
    ANALYTICA CHIMICA ACTA, 1997, 355 (2-3) : 121 - 127
  • [45] Laser ablation inductively coupled plasma mass spectrometry for the determination of trace elements in soil
    Lee, YL
    Chang, CC
    Jiang, SJ
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2003, 58 (03) : 523 - 530
  • [46] Determination of trace elements in sedimentary rock samples by Inductively Coupled Plasma mass spectrometry
    Zheng, P. -X.
    Zhou, Y.
    Wang, T. -F.
    Zhang, Y. -Y.
    Liu, L.
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2008, 72 (12) : A1097 - A1097
  • [47] Study on the Determination of Trace Elements in Bitter Almond by Inductively Coupled Plasma Mass Spectrometry
    Liu Hong-wei
    Xie Hua-lin
    Nie Xi-du
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33 (05) : 1354 - 1356
  • [48] Determination of trace elements in Bouregreg River water by inductively coupled plasma mass spectrometry
    Hakam, O. K.
    Bounouira, H.
    Choukri, A.
    Cherkaoui, R.
    Chakiri, S.
    SPECTROSCOPY LETTERS, 2008, 41 (06) : 267 - 272
  • [50] Determination of Trace Elements in Sulfide Samples by Inductively Coupled Plasma-Mass Spectrometry
    Yin Xue-Bo
    Zeng Zhi-Gang
    Li San-Zhong
    Wu Li
    Wang Xiao-Yuan
    Zhang Guo-Liang
    Chen Shuai
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 39 (08) : 1228 - 1232