Distal biceps brachii tendon repair - An in vitro biomechanical study of tendon reattachment

被引:84
作者
Berlet, GC [1 ]
Johnson, JA [1 ]
Milne, AD [1 ]
Patterson, SD [1 ]
King, GJW [1 ]
机构
[1] St Josephs Hlth Ctr, Hand & Upper Limb Ctr, Musculoskeletal Res Lab, London, ON N6A 4L6, Canada
关键词
D O I
10.1177/03635465980260031501
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Clinical reports suggest that suture anchors can simplify repair of distal biceps tendon avulsions. In this study, fixation strengths of Mitek and Statak suture anchors were compared with strength of reattachment using transosseous suture tunnels in eight cadaveric radii. Cyclic loading and load-to-failure testing were performed: No specimen failed during testing to 50 N for 3600 cycles; however, four of the Mitek anchors and one of the Statak anchors protruded out of the medullary canal. The mean load to failure of the Mitek suture anchor complexes was 220 +/- 54 N, that of the Statak suture anchor complexes was 187 +/- 64 N, and that of the transosseous sutures was 307 +/- 142 N. There was no significant difference in the failure load or mechanism of failure between the Statak and Mitek anchors. Transosseous sutures failed at significantly greater loads on static testing than the suture anchors. Cyclic loading results suggest that the bony fixation achieved using these three techniques should be sufficient to allow immediate passive mobilization of the elbow after surgery. Protrusion of the suture anchors out of the tuberosity during cyclic loading is a concern because of potential development of a gap at the repair site and interference with forearm rotation.
引用
收藏
页码:428 / 432
页数:5
相关论文
共 23 条
  • [1] AGINS HJ, 1988, CLIN ORTHOP RELAT R, P34
  • [2] MUSCLES ACROSS THE ELBOW JOINT - A BIOMECHANICAL ANALYSIS
    AN, KN
    HUI, FC
    MORREY, BF
    LINSCHEID, RL
    CHAO, EY
    [J]. JOURNAL OF BIOMECHANICS, 1981, 14 (10) : 659 - +
  • [3] RUPTURE OF THE DISTAL TENDON OF THE BICEPS BRACHII - OPERATIVE VERSUS NON-OPERATIVE TREATMENT
    BAKER, BE
    BIERWAGEN, D
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (03) : 414 - 417
  • [4] THE ULTIMATE STRENGTH OF SUTURE ANCHORS
    BARBER, FA
    HERBERT, MA
    CLICK, JN
    [J]. ARTHROSCOPY, 1995, 11 (01): : 21 - 28
  • [5] SUTURE ANCHOR FAILURE STRENGTH - AN IN-VIVO STUDY
    BARBER, FA
    CAWLEY, P
    PRUDICH, JF
    [J]. ARTHROSCOPY, 1993, 9 (06): : 647 - 652
  • [6] REPAIR OF AVULSED INSERTION OF BICEPS - A NEW TECHNIQUE IN 4 CASES
    BARNES, SJ
    COLEMAN, SG
    GILPIN, D
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (06): : 938 - 939
  • [7] A METHOD FOR REINSERTION OF THE DISTAL BICEPS BRACHII TENDON
    BOYD, HB
    ANDERSON, LD
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1961, 43 (07) : 1041 - 1043
  • [8] PULL-OUT STRENGTH OF 5 SUTURE ANCHORS
    CARPENTER, JE
    FISH, DN
    HUSTON, LJ
    GOLDSTEIN, SA
    [J]. ARTHROSCOPY, 1993, 9 (01): : 109 - 113
  • [9] REPAIR OF DISTAL BICEPS TENDON RUPTURES IN ATHLETES
    DALESSANDRO, DF
    SHIELDS, CL
    TIBONE, JE
    CHANDLER, RW
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 1993, 21 (01) : 114 - 119
  • [10] Dobbie RP., 1941, Am J Surg, V51, P662