EVALUATION OF COUNTING EFFICIENCIES OF A WHOLE-BODY COUNTER USING MONTE CARLO SIMULATION WITH VOXEL PHANTOMS

被引:17
|
作者
Takahashi, Masa [1 ]
Kinase, Sakae [1 ]
Kramer, Richard [2 ]
机构
[1] Japan Atom Energy Agcy, Tokai, Ibaraki 3191195, Japan
[2] Univ Fed Pernambuco, BR-50740540 Recife, PE, Brazil
关键词
CALIBRATION; CONSTRUCTION; ADULT;
D O I
10.1093/rpd/ncq417
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In the 2007 recommendations of the International Commission on Radiological Protection, it is mentioned that the reference voxel phantoms are used for calculation of effective dose. From the standpoint of internal dosimetry services, calibration methods of whole-body counters using the voxel phantoms are of considerable practical interest. In the present study, counting efficiencies of a whole-body counter at the Japan Atomic Energy Agency (JAEA) were evaluated using Monte Carlo simulations with two voxel phantoms, 'MAX06', which has organ masses corresponding to those of the reference male, and 'Otoko', which is a representation for average Japanese male. To validate the calculation methods of the present study, calculations for the bottle manikin absorption phantom were also performed and compared with experiments. Consequently, it was found that the Monte Carlo simulation with voxel phantoms is a significant tool for the calibration of the JAEA whole-body counter.
引用
收藏
页码:407 / 410
页数:4
相关论文
共 50 条
  • [1] MONTE CARLO SIMULATION OF A WHOLE-BODY COUNTER USING IGOR PHANTOMS
    Bochud, Francois O.
    Laedermann, Jean-Pascal
    Baechler, Sebastien
    Bailat, Claude J.
    Boschung, Markus
    Aroua, Abbas
    Mayer, Sabine
    RADIATION PROTECTION DOSIMETRY, 2014, 162 (03) : 280 - 288
  • [2] Application of voxel phantoms and Monte Carlo method to whole-body counter calibration
    Kinase, S.
    Takagi, S.
    Noguchi, H.
    Saito, K.
    RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 189 - 193
  • [3] Estimation of the counting efficiencies for individual subjects in Cs-137 whole-body counting, using voxel phantoms
    Ishikawa, T
    Uchiyama, M
    RADIATION PROTECTION DOSIMETRY, 1997, 71 (03) : 195 - 200
  • [4] Monte Carlo simulation of lung counting efficiency using a whole-body counter at a nuclear power plant
    Dongming, L.
    Shuhai, J.
    Houwen, L.
    RADIOPROTECTION, 2016, 51 (01) : 59 - 63
  • [5] COMPARISON OF TWO ANTHROPOMORPHIC PHANTOMS AS A CALIBRATION TOOL FOR WHOLE-BODY COUNTER USING MONTE CARLO SIMULATIONS
    Manohari, M.
    Mathiyarasu, R.
    Rajagopal, V.
    Venkatraman, B.
    RADIATION PROTECTION DOSIMETRY, 2015, 164 (03) : 298 - 303
  • [6] Application of voxel phantoms in whole-body counting for the validation of calibration phantoms and the assessment of uncertainties
    de Carlan, L.
    Roch, P.
    Blanchardon, E.
    Franck, D.
    RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 477 - 482
  • [7] A MONTE CARLO CALIBRATION OF A WHOLE BODY COUNTER USING THE ICRP COMPUTATIONAL PHANTOMS
    Nilsson, Jenny
    Isaksson, Mats
    RADIATION PROTECTION DOSIMETRY, 2015, 163 (04) : 458 - 467
  • [8] Evaluation of specific absorbed fractions in voxel phantoms using Monte Carlo simulation
    Kinase, S
    Zankl, M
    Kuwabara, J
    Sato, K
    Noguchi, H
    Funabiki, J
    Saito, K
    RADIATION PROTECTION DOSIMETRY, 2003, 105 (1-4) : 557 - 563
  • [9] USE OF PHOTOGRAPHIC IMAGES TO CONSTRUCT VOXEL PHANTOMS FOR USE IN WHOLE-BODY COUNTING
    Kim, Ji Seok
    Ha, Wi Ho
    Jeong, Jong Hwi
    Cho, Kun-Woo
    Lee, Jai Ki
    RADIATION PROTECTION DOSIMETRY, 2010, 138 (02) : 119 - 122
  • [10] Monte-Carlo simulations with mathematical phantoms to investigate the effectiveness of a whole-body counter for thyroid measurement
    Tani, Kotaro
    Igarashi, Yu
    Kim, Eunjoo
    Iimoto, Takeshi
    Kurihara, Osamu
    RADIATION MEASUREMENTS, 2020, 135