Imidazolium ionic liquid-enhanced poly(quinine)-modified silica as a new multi-mode chromatographic stationary phase for separation of achiral and chiral compounds

被引:47
|
作者
Zhou, Hang [1 ,2 ]
Chen, Jia [1 ]
Li, Hui [1 ]
Quan, Kaijun [1 ]
Zhang, Yingshan [3 ]
Qiu, Hongdeng [1 ,2 ]
机构
[1] Chinese Acad Sci, Lanzhou Inst Chem Phys, Key Lab Nat Med Gansu Prov, CAS Key Lab Chem Northwestern Plant Resources, Lanzhou 730000, Peoples R China
[2] Chinese Acad Sci, Univ Chinese Acad Sci, Beijing 100039, Peoples R China
[3] Gansu Prov Tradit Chinese Med Modern Pharmaceut E, Lanzhou 730000, Peoples R China
基金
中国国家自然科学基金;
关键词
Imidazolium; Ionic liquids; Quinine; Multi-mode stationary phase; HPLC; DEEP EUTECTIC SOLVENTS; REVERSED-PHASE; QUANTITATIVE-ANALYSIS; PERFORMANCE; PARTICLES; COLUMNS; WATER;
D O I
10.1016/j.talanta.2020.120743
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, a novel imidazolium ionic liquid-functionalized poly(quinine)-modified silica stationary phase (Sil-PQn-MIm) was successfully synthesized via surface radical chain transfer and nucleophilic substitution reaction. The modified silica was confirmed by series of characterizations including Fourier transform infrared spectro-scopy (FT-IR), elemental analysis (EA), transmission electron microscopy (TEM) and thermogravimetric analysis (TGA). The multi-mode chromatographic performances of the Sil-PQn-MIm column were investigated by anion-exchange mode for separation of aromatic acid samples, hydrophilic interaction mode for separation of nucleosides/nucleobases and sulfanilamides, and reversed-phase mode for separation of alkylbenzenes, benzene and polycyclic aromatic hydrocarbons (PAHs), and the Tanaka test mixtures, respectively. As expected, compared to the Sil-PQn column only with quinine as functional group, the Sil-PQn-MIm column further modified by imidazolium ionic liquid possessed higher separation performance, especially for the separation of nucleosides/nucleobases. The effects including buffer concentration, pH, organic solvent content and column temperature on chromatographic performance were studied, which proved that multiple interactions including electrostatic, hydrophobic and hydrophilic interactions can be simultaneously existed between the stationary phase and the analytes. In addition, reproducibility and efficiency of the Sil-PQn-Mlm column were also investigated, the results illustrated that the stationary phase have good enough reproducibility (RSDs 0.15%-0.72%, n = 7) and high efficiency (plates per meter, similar to 90000 plates/m). In conclusion, the prepared stationary phase with multiplemode retention capabilities could realize separation for various types of samples by optimizing chromatographic conditions, even for some chiral compounds.
引用
收藏
页数:8
相关论文
共 17 条
  • [1] Ionic liquid-modified silica as a new stationary phase for chromatographic separation
    X. Wan
    M. Tian
    K. H. Row
    Journal of Analytical Chemistry, 2010, 65 : 798 - 802
  • [2] Ionic liquid-modified silica as a new stationary phase for chromatographic separation
    Wan, X.
    Tian, M.
    Row, K. H.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 65 (08) : 798 - 802
  • [3] New poly(ionic liquid)-grafted silica multi-mode stationary phase for anion-exchange/reversed-phase/hydrophilic interaction liquid chromatography
    Qiu, Hongdeng
    Mallik, Abul K.
    Takafuji, Makoto
    Jiang, Shengxiang
    Ihara, Hirotaka
    ANALYST, 2012, 137 (11) : 2553 - 2555
  • [4] Multi-mode chromatographic evaluation of a new lysine-silica stationary phase for high-performance liquid chromatography
    Ray, Sudipta
    Takafuji, Makoto
    Ihara, Hirotaka
    ANALYTICAL METHODS, 2014, 6 (19) : 7674 - 7680
  • [5] Ionic liquid functionalized β-cyclodextrin and C18 mixed-mode stationary phase with achiral and chiral separation functions
    Zhou, Jingqiu
    Ren, Xiujun
    Luo, Qiurong
    Gao, Die
    Fu, Qifeng
    Zhou, Di
    Zu, Fengjiao
    Xia, Zhining
    Wang, Lujun
    Journal of Chromatography A, 2020, 1634
  • [6] Ionic liquid functionalized β-cyclodextrin and C18 mixed-mode stationary phase with achiral and chiral separation functions
    Zhou, Jingqiu
    Ren, Xiujun
    Luo, Qiurong
    Gao, Die
    Fu, Qifeng
    Zhou, Di
    Zu, Fengjiao
    Xia, Zhining
    Wang, Lujun
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1634
  • [7] Polymerized phosphonium ionic liquid functionalized silica microspheres as mixed-mode stationary phase for liquid chromatographic separation of phospholipids
    Liu, Delu
    Wang, Haiyan
    Liang, Mengying
    Nie, Yangyang
    Liu, Yanli
    Yin, Mingyuan
    Qiao, Xiaoqiang
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1660
  • [8] Characterization and multi-mode liquid chromatographic application of 4-propylaminomethyl benzoic acid bonded silica-A zwitterionic stationary phase
    Wijekoon, A.
    Gangoda, M. E.
    Gregory, R. B.
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1270 : 212 - 218
  • [9] Ionic liquid- functionalized graphene quantum dot- bonded silica as multi- mode HPLC stationary phase with enhanced selectivity for acid compounds
    Wu, Qi
    Sun, Yaming
    Gao, Jie
    Chen, Lixiao
    Dong, Shuqing
    Luo, Guoying
    Li, Hui
    Wang, Litao
    Zhao, Liang
    NEW JOURNAL OF CHEMISTRY, 2018, 42 (11) : 8672 - 8680
  • [10] Dicationic imidazolium ionic liquid modified silica as a novel reversed-phase/anion-exchange mixed-mode stationary phase for high-performance liquid chromatography
    Sun, Min
    Feng, Juanjuan
    Wang, Xiaojiao
    Duan, Huimin
    Li, Leilei
    Luo, Chuannan
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (16) : 2153 - 2159