On-line preconcentration and determination of chromium in parenteral solutions by inductively coupled plasma optical emission spectrometry

被引:38
作者
Gil, RA
Cerutti, S
Gásquez, JA
Olsina, RA
Martinez, LD
机构
[1] Natl Univ San Luis, Dept Analyt Chem, Fac Chem Biochem & Pharm, RA-5700 San Luis, Argentina
[2] Consejo Nacl Invest Cient & Tecn, Buenos Aires, DF, Argentina
关键词
chromium speciation; on-line preconcentration; activated carbon; ICP-OES; parenteral solutions;
D O I
10.1016/j.sab.2005.02.008
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A method for the preconcentration and speciation of chromium was developed. On-line preconcentration and determination were obtained using inductively coupled plasma optical emission spectrometry (ICP-OES) coupled with flow injection. To determinate the chromium (III) present in parenteral solutions, chromium was retained on activated carbon at pH 5.0. On the other hand, a step of reduction was necessary in order to determine total chromium content. The Cr(VI) concentration was then determined by difference between the total chromium concentration and that of Cr(III). A sensitivity enrichment factor of 70-fold was obtained with respect to the chromium determination by ICP-OES without preconcentration. The detection limit for the preconcentration of 25 ml of sample was 29 ng l(-1). The precision for the 10 replicate determinations at the 5 mu g l(-1) Cr level was 2.3% relative standard deviation, calculated with the peak heights. The calibration graph using the preconcentration method for chromium species was linear with a correlation coefficient of 0.9995 at levels near the detection limits up to at least 60 mu g l(-1). The method can be applied to the determination and speciation of chromium in parenteral solutions. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:531 / 535
页数:5
相关论文
共 22 条
  • [1] Flame atomic absorption spectrometric determination of chromium(VI) by on-line preconcentration system using a PTFE packed column
    Anthemidis, AN
    Zachariadis, GA
    Kougoulis, JS
    Stratis, JA
    [J]. TALANTA, 2002, 57 (01) : 15 - 22
  • [2] On-line preconcentration/determination of cadmium in drinking water on activated carbon using 8-hydroxyquinoline in a flow injection system coupled to an inductively coupled plasma optical emission spectrometer
    Cerutti, S
    Silva, MF
    Gásquez, JA
    Olsina, RA
    Martinez, LD
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2003, 58 (01) : 43 - 50
  • [3] Surface charge and metal ion adsorption on an H-type activated carbon: experimental observation and modeling simulation by the surface complex formation approach
    Chen, JP
    Lin, MS
    [J]. CARBON, 2001, 39 (10) : 1491 - 1504
  • [4] Development of a new system for the speciation of chromium in natural waters and human urine samples by combining ion exchange and ETA-AAS
    Cordero, MTS
    Alonso, EIV
    de Torres, AG
    Pavón, JMC
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (03) : 398 - 403
  • [5] *EPA, 1998, 8540299 CAS IRIS US
  • [6] *EPA, 1998, 16065831 IRIS US EPA
  • [7] Fang Z., 1993, FLOW INJECTION SEPAR
  • [8] FARIAS GM, 2003, ATOM SPECTROSC, V24, P213
  • [9] TRACE-ELEMENTS IN PARENTERAL MICRONUTRITION
    LEUNG, FY
    [J]. CLINICAL BIOCHEMISTRY, 1995, 28 (06) : 561 - 566
  • [10] Parenteral nutrition practices in hospital pharmacies in Switzerland, France, and Belgium
    Maisonneuve, N
    Raguso, CA
    Paoloni-Giacobino, A
    Mühebach, S
    Corriol, O
    Saubion, JL
    Hecq, JD
    Bailly, A
    Berger, M
    Pichard, C
    [J]. NUTRITION, 2004, 20 (06) : 528 - 535